Complications of invasive monitoring used in intractable pediatric epilepsy

被引:57
作者
Simon, SL
Telfeian, A
Duhaime, AC
机构
[1] Univ Penn, Dept Neurosurg, Philadelphia, PA 19104 USA
[2] Childrens Hosp Philadelphia, Div Neurosurg, Philadelphia, PA 19104 USA
[3] Dartmouth Hitchcock Med Ctr, Div Neurosurg, Lebanon, NH 03766 USA
关键词
epilepsy; invasive monitoring; pediatric epilepsy; complications; infection;
D O I
10.1159/000067555
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Invasive monitoring for intractable epilepsy is useful when the epileptogenic focus is in question even after an extensive noninvasive presurgical evaluation, or when the epileptogenic focus is located in or near eloquent cortex. From June 1989 to June 2001 at the Children's Hospital of Philadelphia, 64 children with intractable epilepsy underwent 67 invasive monitoring procedures as part of their presurgical evaluation. The average age at implantation was 10 years. In all but two cases, subdural strips and grids were used. Depth electrodes, when used, were placed stereotactically or under direct vision. The average duration of the monitoring period was 5.87 days. Every patient had intradural cultures sent during removal of the electrodes, and lumbar punctures were performed in 15 patients. Twenty-one patients had at least one episode of a CSF leak. Of the 67 patients, 10 had positive intradural cultures, only 1 of whom had a positive lumbar puncture and none of whom developed clinically significant meningitis. No clinically relevant hemorrhages occurred as a result of the invasive monitoring. One patient did have a transient visual field loss after placement of an occipital grid. While CSF leaks are common after invasive monitoring despite precautions, clinically significant CSF infections are uncommon and appear to be unrelated,to the duration of monitoring, the occurrence of a CSF leak or the length of time the patient is on perioperative antibiotics. We conclude that invasive monitoring for intractable epilepsy is generally safe. Copyright (C) 2003 S. Karger AG, Basel.
引用
收藏
页码:47 / 52
页数:6
相关论文
共 20 条
[1]  
ADELSON PD, 1995, PEDIATR NEUROSURG, V22, P174
[2]  
ADELSON PD, 1995, NEUROSURG CLIN N AM, V6, P491
[3]   SUBDURAL AND DEPTH ELECTRODES IN THE PRESURGICAL EVALUATION OF EPILEPSY [J].
BEHRENS, E ;
ZENTNER, J ;
VANROOST, D ;
HUFNAGEL, A ;
ELGER, CE ;
SCHRAMM, J .
ACTA NEUROCHIRURGICA, 1994, 128 (1-4) :84-87
[4]   Invasive monitoring of limbic epilepsy using stereotactic depth and subdural strip electrodes: Surgical technique [J].
Blatt, DR ;
Roper, SN ;
Friedman, WA .
SURGICAL NEUROLOGY, 1997, 48 (01) :74-79
[5]   Surgical technique for the insertion of grids and strips for invasive monitoring in children with intractable epilepsy [J].
Bruce, DA ;
Bizzi, JWJ .
CHILDS NERVOUS SYSTEM, 2000, 16 (10-11) :724-730
[6]   Results of surgery in patients with refractory extratemporal epilepsy with normal or nonlocalizing magnetic resonance findings investigated with subdural grids [J].
Cukiert, A ;
Buratini, JA ;
Machado, E ;
Sousa, A ;
Vieira, JO ;
Argentoni, M ;
Forster, C ;
Baldauf, C .
EPILEPSIA, 2001, 42 (07) :889-894
[7]  
Duchowny M, 2000, EPILEPTIC DISORD, V2, P219
[8]  
Jayakar P, 1994, J Child Neurol, V9 Suppl 2, P61
[9]   Invasive EEG monitoring in children: When, where, and what? [J].
Jayakar, P .
JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 1999, 16 (05) :408-418
[10]   Complications and results of subdural grid electrode implantation in epilepsy surgery [J].
Lee, WS ;
Lee, JK ;
Lee, SA ;
Kang, JK ;
Ko, TS .
SURGICAL NEUROLOGY, 2000, 54 (05) :346-351