Measurement of percentage depth dose and lateral beam profile for kilovoltage x-ray therapy beams

被引:33
|
作者
Li, XA
Ma, CM
Salhani, D
机构
[1] Ottawa Reg Canc Ctr, Dept Med Phys, Ottawa, ON K1Y 4K7, Canada
[2] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1997年 / 42卷 / 12期
关键词
D O I
10.1088/0031-9155/42/12/019
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this work, nine commonly used dosimetry detectors have been investigated to determine suitable relative dosimeters for kilovoltage x-ray beams. By comparison with the Monte Carlo calculated data, it was determined that for the detectors studied the PTW N23342, Markus and NACP parallel-plate chambers are more suitable for the measurement of percentage depth dose (PDD) data for this beam quality range with an uncertainty of about 3%. A diode detector may be used to measure the PDD for the 100 kVp beam, but it is not suitable for higher energies (300 kVp). The Capintec parallel-plate chamber may be adequate for medium-energy photons, but it has a slightly higher uncertainty for low-energy x-rays (100 kVp). For the measurement of beam profiles, diode and film yield incorrect profile tails, which can be corrected using the RK ionization chamber.
引用
收藏
页码:2561 / 2568
页数:8
相关论文
共 50 条
  • [41] An evaluation of ionization chambers for the relative dosimetry of kilovoltage x-ray beams
    Hill, Robin
    Mo, Zhao
    Haque, Mamoon
    Baldock, Clive
    MEDICAL PHYSICS, 2009, 36 (09) : 3971 - 3981
  • [42] Measurement of the dose deposition characteristics of x-ray fluoroscopy beams in water
    Fetterly, KA
    Gerbi, BJ
    Alaei, P
    Geise, RA
    MEDICAL PHYSICS, 2001, 28 (02) : 205 - 209
  • [43] Measurement of depth dose curves for radiation of RTA X-ray unit
    Vasil'ev, V.N.
    Kokontsev, A.A.
    Meditsinskaya Tekhnika, 1997, (05): : 11 - 14
  • [44] ITAR: A modified TAR method to determine depth dose distribution for an ophthalmic device that performs kilovoltage x-ray pencil-beam stereotaxy
    Hanlon, Justin
    Chell, Erik
    Firpo, Michael
    Koruga, Igor
    MEDICAL PHYSICS, 2014, 41 (02)
  • [45] MEASUREMENT OF PEAK KILOVOLTAGE OF LOW ENERGY X-RAY GENERATORS
    JONES, DEA
    PHYSICS IN MEDICINE AND BIOLOGY, 1969, 14 (03): : 495 - &
  • [46] Impact of X-ray energy on absorbed dose assessed with Monte Carlo simulations in a mouse tumor and in nearest organs irradiated with kilovoltage X-ray beams
    Hamdi, M.
    Mimi, M.
    Bentourkia, M.
    CANCER RADIOTHERAPIE, 2017, 21 (03): : 190 - 198
  • [47] Absorbed dose conversion factors for therapeutic kilovoltage and megavoltage x-ray beams calculated by the Monte Carlo method
    Knight, RT
    MEDICAL PHYSICS, 1997, 24 (02) : 336 - 336
  • [48] Acceptance and commissioning of a modern kilovoltage X-ray therapy unit
    Aspradakis, M. M.
    Zucchetti, P.
    Seiler, R.
    Goetzfried, Th
    von Deschwanden, A.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 (08) : 751 - 751
  • [49] Output factor measurements for a kilovoltage x-ray therapy unit
    Healy B.J.
    Gibbs A.
    Murry R.L.
    Prunster J.E.
    Nitschke K.N.
    Australasian Physics & Engineering Sciences in Medicine, 2005, 28 (2): : 115 - 121
  • [50] Algorithm for X-ray Scatter, Beam-Hardening, and Beam Profile Correction in Diagnostic (Kilovoltage) and Treatment (Megavoltage) Cone Beam CT
    Maltz, Jonathan S.
    Gangadharan, Bijumon
    Bose, Supratik
    Hristov, Dimitre H.
    Faddegon, Bruce A.
    Paidi, Ajay
    Bani-Hashemi, Ali R.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (12) : 1791 - 1810