Diagnostic Accuracy of Percutaneous Transthoracic Needle Lung Biopsies: A Multicenter Study

被引:59
作者
Lee, Kyung Hee [1 ]
Lim, Kun Young [2 ]
Suh, Young Joo [3 ]
Hur, Jin [3 ,4 ]
Han, Dae Hee [5 ]
Kang, Mi-Jin [6 ]
Choo, Ji Yung [7 ]
Kim, Cherry [7 ]
Kim, Jung Im [8 ]
Yoon, Soon Ho [9 ]
Lee, Woojoo [10 ]
Park, Chang Min [9 ,11 ]
机构
[1] Seoul Natl Univ, Dept Radiol, Bundang Hosp, Seongnam, South Korea
[2] Natl Canc Ctr, Dept Radiol, Goyang, South Korea
[3] Yonsei Univ, Severance Hosp, Dept Radiol, Coll Med, Seoul, South Korea
[4] Yonsei Univ, Severance Hosp, Res Inst Radiol Sci, Coll Med, Seoul, South Korea
[5] Catholic Univ Korea, Seoul St Marys Hosp, Coll Med, Dept Radiol, Seoul, South Korea
[6] Inje Univ, Dept Radiol, Sanggye Paik Hosp, Seoul, South Korea
[7] Korea Univ, Ansan Hosp, Dept Radiol, Coll Med, Ansan, South Korea
[8] Kyung Hee Univ, Kyung Hee Univ Hosp Gangdong, Coll Med, Dept Radiol, Seoul, South Korea
[9] Seoul Natl Univ, Dept Radiol, Coll Med, Seoul, South Korea
[10] Inha Univ, Dept Stat, Incheon, South Korea
[11] Seoul Natl Univ, Inst Radiat Med, Med Res Ctr, Seoul, South Korea
关键词
Image-guided biopsy; Sensitivity and specificity; Lung neoplasms; Multicenter study; CONE-BEAM CT; PULMONARY-LESIONS; ASPIRATION BIOPSY; GUIDED BIOPSY; REPEAT BIOPSY; NODULES; EXPERIENCE; CANCER; MM;
D O I
10.3348/kjr.2019.0189
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To measure the diagnostic accuracy of percutaneous transthoracic needle lung biopsies (PTNBs) on the basis of the intention-to-diagnose principle and identify risk factors for diagnostic failure of PTNBs in a multi-institutional setting. Materials and Methods: A total of 9384 initial PTNBs performed in 9239 patients (mean patient age, 65 years [range, 20-99 years]) from January 2010 to December 2014 were included. The accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of PTNBs for diagnosis of malignancy were measured. The proportion of diagnostic failures was measured, and their risk factors were identified. Results: The overall accuracy, sensitivity, specificity, PPV, and NPV were 91.1% (95% confidence interval [CI], 90.6-91.7%), 92.5% (95% CI, 91.9-93.1%), 86.5% (95% CI, 85.0-87.9%), 99.2% (95% CI, 99.0-99.4%), and 84.3% (95% CI, 82.7-85.8%), respectively. The proportion of diagnostic failures was 8.9% (831 of 9384; 95% CI, 8.3-9.4%). The independent risk factors for diagnostic failures were lesions <= 1 cm in size (adjusted odds ratio [AOR], 1.86; 95% CI, 1.23-2.81), lesion size 1.1-2 cm (1.75; 1.45-2.11), subsolid lesions (1.81; 1.32-2.49), use of fine needle aspiration only (2.43; 1.80-3.28), final diagnosis of benign lesions (2.18; 1.84-2.58), and final diagnosis of lymphomas (10.66; 6.21-18.30). Use of cone-beam CT (AOR, 0.31; 95% CI, 0.13-0.75) and conventional CT-guidance (0.55; 0.32-0.94) reduced diagnostic failures. Conclusion: The accuracy of PTNB for diagnosis of malignancy was fairly high in our large-scale multi-institutional cohort. The identified risk factors for diagnostic failure may help reduce diagnostic failure and interpret the biopsy results.
引用
收藏
页码:1300 / 1310
页数:11
相关论文
共 22 条
  • [1] Prospective Randomized Trial for Image Guided Biopsy Using Cone-Beam CT Navigation Compared with Conventional CT
    Abi-Jaoudeh, Nadine
    Fisher, Teresa
    Jacobus, John
    Skopec, Marlene
    Radaelli, Alessandro
    Van der Born, Imramsjah Martijn
    Wesley, Robert
    Wood, Bradford J.
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 27 (09) : 1342 - 1349
  • [2] Percutaneous CT-Guided Aspiration and Core Biopsy of Pulmonary Nodules Smaller Than 1 cm: Analysis of Outcomes of 305 Procedures From a Tertiary Referral Center
    Choi, Sang Hyun
    Chae, Eun Jin
    Kim, Ji-Eun
    Kim, Eun Young
    Oh, Sang Young
    Hwang, Hye Jeon
    Lee, Hyun Joo
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (05) : 964 - 970
  • [3] Percutaneous transthoracic needle biopsy of small (aparts per thousandcurrency sign1 cm) lung nodules under C-arm cone-beam CT virtual navigation guidance
    Choo, Ji Yung
    Park, Chang Min
    Lee, Nyoung Keun
    Lee, Sang Min
    Lee, Hyun-Ju
    Goo, Jin Mo
    [J]. EUROPEAN RADIOLOGY, 2013, 23 (03) : 712 - 719
  • [4] Negative Predictive Value of Transthoracic Core-Needle Biopsy A Multicenter Study
    Fontaine-Delaruelle, Clara
    Souquet, Pierre-Jean
    Gamondes, Delphine
    Pradat, Eric
    De Leusse, Aurelie
    Ferretti, Gilbert R.
    Couraud, Sebastien
    [J]. CHEST, 2015, 148 (02) : 472 - 480
  • [5] Complication rates of CT-guided transthoracic lung biopsy: meta-analysis
    Heerink, W. J.
    de Bock, G. H.
    de Jonge, G. J.
    Groen, H. J. M.
    Vliegenthart, R.
    Oudkerk, M.
    [J]. EUROPEAN RADIOLOGY, 2017, 27 (01) : 138 - 148
  • [6] CT screening for lung cancer: Frequency and significance of part-solid and nonsolid nodules
    Henschke, CI
    Yankelevitz, DF
    Mirtcheva, R
    McGuinness, G
    McCauley, D
    Miettinen, OS
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (05) : 1053 - 1057
  • [7] CT Fluoroscopy-Guided Biopsy of 1,000 Pulmonary Lesions Performed With 20-Gauge Coaxial Cutting Needles: Diagnostic Yield and Risk Factors for Diagnostic Failure
    Hiraki, Takao
    Mimura, Hidefumi
    Gobara, Hideo
    Iguchi, Toshihiro
    Fujiwara, Hiroyasu
    Sakurai, Jun
    Matsui, Yusuke
    Inoue, Daisaku
    Toyooka, Shinichi
    Sano, Yoshifumi
    Kanazawa, Susumu
    [J]. CHEST, 2009, 136 (06) : 1612 - 1617
  • [8] Repeat biopsy of patients with acquired resistance to EGFR TKIs: implications of biopsy-related factors on T790M mutation detection
    Kim, Hyungjin
    Chae, Kum Ju
    Yoon, Soon Ho
    Kim, Miso
    Keam, Bhumsuk
    Kim, Tae Min
    Kim, Dong-Wan
    Goo, Jin Mo
    Park, Chang Min
    [J]. EUROPEAN RADIOLOGY, 2018, 28 (02) : 861 - 868
  • [9] Non-specific benign pathological results on transthoracic core-needle biopsy: how to differentiate false-negatives?
    Kim, Jung Im
    Park, Chang Min
    Kim, Hyungjin
    Lee, Jong Hyuk
    Goo, Jin Mo
    [J]. EUROPEAN RADIOLOGY, 2017, 27 (09) : 3888 - 3895
  • [10] Nondiagnostic Percutaneous Transthoracic Needle Biopsy of Lung Lesions: A Multicenter Study of Malignancy Risk
    Lee, Kyung Hee
    Lim, Kun Young
    Suh, Young Joo
    Hur, Jin
    Han, Dae Hee
    Kang, Mi-Jin
    Choo, Ji Yung
    Kim, Cherry
    Kim, Jung Im
    Yoon, Soon Ho
    Lee, Woojoo
    Park, Chang Min
    [J]. RADIOLOGY, 2019, 290 (03) : 814 - 823