Estimating changes in cardiac output using an implanted hemodynamic monitor in heart failure patients

被引:5
|
作者
Stahlberg, Marcus [1 ]
Damgaard, Morten [2 ]
Ersgard, David
Norsk, Peter [2 ]
Karamanoglu, Mustafa [3 ]
Linde, Cecilia
Braunschweig, Frieder
机构
[1] Karolinska Inst, Dept Cardiol, Res Unit, Karolinska Univ Hosp, S-17176 Stockholm, Sweden
[2] Univ Copenhagen, Dept Biomed Sci, Fac Hlth Sci, DK-1168 Copenhagen, Denmark
[3] Medtronic Inc, NT&D Res, Minneapolis, MN USA
关键词
Cardiac output; hemodynamic monitoring; heart failure; pressure waveform; RIGHT-VENTRICULAR PRESSURE; FEASIBILITY; MULTICENTER; DIAGNOSIS; SYSTEM;
D O I
10.3109/14017431003631987
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. The aim of this study was to evaluate an algorithm that estimates changes in cardiac output (CO) from right ventricular (RV) pressure waveforms derived from an implantable hemodynamic monitor (IHM) in heart failure patients. Design. Twelve heart failure patients (NYHA II-III, EF 32%) with an implantable hemodynamic monitor (Chronicle (R)) were included in this study. Changes in cardiac output were provoked by body position change at rest (left lateral supine, horizontal supine, sitting, and standing) and a steady state bicycle exercise at 20 watts. Estimated CO derived from the IHM (CO(IHM)) was compared to CO measured with inert gas rebreathing (CO(RB)), echocardiography (COE(CHO)) and impedance cardiography (CO(ICG)). CO(RB) was considered the reference method. Results. The median intra-patient correlation coefficient comparing CO(RB) and CO(IHM) was 0.83 (range: 0.63-0.98). Comparing CO(RB) with CO(ECHO) and CO(ICG) resulted in mean intra-patient correlation coefficients of 0.73 (-0.29-0.94) and 0.63 (-0.29-0.96). In a statistical model where slope and intercept was considered random between patients the coefficient of determination (R(2)) comparing CO(RB) and CO(IHM) was 0.91. Mean bias was -0.39 L/min (11%). Limits of agreement were +/- 1.56 L/min and relative error was 21%. Conclusions. A simple algorithm based on RV pressure wave form characteristics derived from an IHM can be used to estimate changes in CO in heart failure patients. These findings encourage further research aiming to improve and validate the algorithm.
引用
收藏
页码:201 / 208
页数:8
相关论文
共 50 条
  • [31] Incidence of atrial fibrillation in patients with an insertable cardiac monitor and symptomatic heart failure
    Khan, Muhammad Shahzeb
    Zile, Michael R.
    Kahwash, Rami
    Sarkar, Shantanu
    Van Dorn, Brian
    Koehler, Jodi
    Franco, Noreli
    Gerritse, Bart
    Butler, Javed
    ESC HEART FAILURE, 2024,
  • [32] Improved Diastolic Function Is Associated With Higher Cardiac Output in Patients With Heart Failure Irrespective of Left Ventricular Ejection Fraction
    Tobushi, Tomoyuki
    Nakano, Masatsugu
    Hosokawa, Kazuya
    Koga, Hidenobu
    Yamada, Akira
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2017, 6 (03):
  • [33] Afterload-related cardiac performance is a powerful hemodynamic predictor of mortality in patients with chronic heart failure
    Wu, Yihang
    Tian, Pengchao
    Liang, Lin
    Chen, Yuyi
    Feng, Jiayu
    Huang, Boping
    Huang, Liyan
    Zhao, Xuemei
    Wang, Jing
    Guan, Jingyuan
    Li, Xinqing
    Zhang, Yuhui
    Zhang, Jian
    THERAPEUTIC ADVANCES IN CHRONIC DISEASE, 2023, 14
  • [34] Remote Hemodynamic-Guided Therapy of Patients With Recurrent Heart Failure Following Cardiac Resynchronization Therapy
    Varma, Niraj
    Bourge, Robert C.
    Stevenson, Lynne Warner
    Costanzo, Maria Rosa
    Shavelle, David
    Adamson, Philip B.
    Ginn, Greg
    Henderson, John
    Abraham, William T.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2021, 10 (05): : 1 - 19
  • [35] Hemodynamic differences among hypertensive patients with and without heart failure using impedance cardiography
    Lopes, Bruno Silva
    Craveiro, Nuno
    Firmino-Machado, Joao
    Ribeiro, Pedro
    Castelo-Branco, Miguel
    THERAPEUTIC ADVANCES IN CARDIOVASCULAR DISEASE, 2019, 13
  • [36] Validation of Noninvasive Measurement of Cardiac Output Using Inert Gas Rebreathing in a Cohort of Patients With Heart Failure and Reduced Ejection Fraction
    Hassan, Mohamed
    Wagdy, Kerolos
    Kharabish, Ahmed
    Selwanos, Peter Philip
    Nabil, Ahmed
    Elguindy, Ahmed
    ElFaramawy, Amr
    Elmahdy, Mahmoud F.
    Mahmoud, Hani
    Yacoub, Magdi H.
    CIRCULATION-HEART FAILURE, 2017, 10 (03)
  • [37] Implant experience with an implantable hemodynamic monitor for the management of symptomatic heart failure
    Steinhaus, D
    Reynolds, DW
    Gadler, F
    Kay, GN
    Hess, MF
    Bennett, T
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (08): : 747 - 753
  • [38] Optimal Utilization and Management of Implanted Cardiac Rhythm Devices in Patients Hospitalized for Heart Failure
    Randolph, Tiffany
    Piccini, Jonathan P.
    HEART FAILURE CLINICS, 2013, 9 (03) : 321 - +
  • [39] Biomarkers of Inflammation in Patients With Chronic Heart Failure and Implanted Devices for Cardiac Resynchronization Therapy
    Kuznetsov, V. A.
    Soldatova, A. M.
    Enina, T. N.
    Shebeko, P. V.
    Rychkov, A. Yu.
    Melnikov, N. N.
    Zateishchikov, D. A.
    KARDIOLOGIYA, 2012, 52 (08) : 38 - 43
  • [40] Reliability of the Ultrasound Cardiac Output Monitor for Pediatric Patients
    Lemson, Joris
    Tibby, Shane M.
    PEDIATRIC CARDIOLOGY, 2016, 37 (03) : 618 - 618