Estimating changes in cardiac output using an implanted hemodynamic monitor in heart failure patients

被引:5
|
作者
Stahlberg, Marcus [1 ]
Damgaard, Morten [2 ]
Ersgard, David
Norsk, Peter [2 ]
Karamanoglu, Mustafa [3 ]
Linde, Cecilia
Braunschweig, Frieder
机构
[1] Karolinska Inst, Dept Cardiol, Res Unit, Karolinska Univ Hosp, S-17176 Stockholm, Sweden
[2] Univ Copenhagen, Dept Biomed Sci, Fac Hlth Sci, DK-1168 Copenhagen, Denmark
[3] Medtronic Inc, NT&D Res, Minneapolis, MN USA
关键词
Cardiac output; hemodynamic monitoring; heart failure; pressure waveform; RIGHT-VENTRICULAR PRESSURE; FEASIBILITY; MULTICENTER; DIAGNOSIS; SYSTEM;
D O I
10.3109/14017431003631987
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. The aim of this study was to evaluate an algorithm that estimates changes in cardiac output (CO) from right ventricular (RV) pressure waveforms derived from an implantable hemodynamic monitor (IHM) in heart failure patients. Design. Twelve heart failure patients (NYHA II-III, EF 32%) with an implantable hemodynamic monitor (Chronicle (R)) were included in this study. Changes in cardiac output were provoked by body position change at rest (left lateral supine, horizontal supine, sitting, and standing) and a steady state bicycle exercise at 20 watts. Estimated CO derived from the IHM (CO(IHM)) was compared to CO measured with inert gas rebreathing (CO(RB)), echocardiography (COE(CHO)) and impedance cardiography (CO(ICG)). CO(RB) was considered the reference method. Results. The median intra-patient correlation coefficient comparing CO(RB) and CO(IHM) was 0.83 (range: 0.63-0.98). Comparing CO(RB) with CO(ECHO) and CO(ICG) resulted in mean intra-patient correlation coefficients of 0.73 (-0.29-0.94) and 0.63 (-0.29-0.96). In a statistical model where slope and intercept was considered random between patients the coefficient of determination (R(2)) comparing CO(RB) and CO(IHM) was 0.91. Mean bias was -0.39 L/min (11%). Limits of agreement were +/- 1.56 L/min and relative error was 21%. Conclusions. A simple algorithm based on RV pressure wave form characteristics derived from an IHM can be used to estimate changes in CO in heart failure patients. These findings encourage further research aiming to improve and validate the algorithm.
引用
收藏
页码:201 / 208
页数:8
相关论文
共 50 条
  • [1] Feasibility of the cardiac output response to stress test in suspected heart failure patients
    Charman, Sarah J.
    Okwose, Nduka C.
    Taylor, Clare J.
    Bailey, Kristian
    Fuat, Ahmet
    Ristic, Arsen
    Mant, Jonathan
    Deaton, Christi
    Seferovic, Petar M.
    Coats, Andrew J. S.
    Hobbs, F. D. Richard
    MacGowan, Guy A.
    Jakovljevic, Djordje G.
    FAMILY PRACTICE, 2022, 39 (05) : 805 - 812
  • [2] Hemodynamic Changes After Administration of Mannitol Measured by a Noninvasive Cardiac Output Monitor
    Sabharwal, Nikki
    Rao, G. S. Umamaheswara
    Ali, Zulifqar
    Radhakrishnan, Muthuchellappan
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 2009, 21 (03) : 248 - 252
  • [3] Cardiac output changes during exercise in heart failure patients: focus on mid-exercise
    Corrieri, Nicoletta
    Del Torto, Alberico
    Vignati, Carlo
    Maragna, Riccardo
    De Martino, Fabiana
    Cellamare, Martina
    Farina, Stefania
    Salvioni, Elisabetta
    Bonomi, Alice
    Agostoni, Piergiuseppe
    ESC HEART FAILURE, 2021, 8 (01): : 55 - 62
  • [4] Hemodynamic effects of levosimendan in patients with low-output heart failure after cardiac surgery
    Labriola, C
    Siro-Brigiani, M
    Carrata, F
    Santangelo, E
    Amantea, B
    INTERNATIONAL JOURNAL OF CLINICAL PHARMACOLOGY AND THERAPEUTICS, 2004, 42 (04) : 204 - 211
  • [5] Hemodynamic evaluation in preterm infants using ultrasonic cardiac output monitor (USCOM)
    Doni, Daniela
    Faraguna, Martha Caterina
    Zannin, Emanuela
    Rinaldi, Alessandro
    Cafolla, Claudia
    Iozzi, Lucia
    Cavalleri, Valeria
    Rigotti, Camilla
    Sinelli, Mariateresa
    Fedeli, Tiziana
    Ventura, Maria Luisa
    EUROPEAN JOURNAL OF PEDIATRICS, 2024, 183 (05) : 2183 - 2192
  • [6] Hemodynamic evaluation in preterm infants using ultrasonic cardiac output monitor (USCOM)
    Daniela Doni
    Martha Caterina Faraguna
    Emanuela Zannin
    Alessandro Rinaldi
    Claudia Cafolla
    Lucia Iozzi
    Valeria Cavalleri
    Camilla Rigotti
    Mariateresa Sinelli
    Tiziana Fedeli
    Maria Luisa Ventura
    European Journal of Pediatrics, 2024, 183 : 2183 - 2192
  • [7] Noninvasive pulse contour analysis for determination of cardiac output in patients with chronic heart failure
    Roth, Sebastian
    Fox, Henrik
    Fuchs, Uwe
    Schulz, Uwe
    Costard-Jaeckle, Angelika
    Gummert, Jan F.
    Horstkotte, Dieter
    Oldenburg, Olaf
    Bitter, Thomas
    CLINICAL RESEARCH IN CARDIOLOGY, 2018, 107 (05) : 395 - 404
  • [8] Central hemodynamic responses during serial exercise tests in heart failure patients using implantable hemodynamic monitors
    Ohlsson, Å
    Steinhaus, D
    Kjellström, B
    Ryden, L
    Bennett, T
    EUROPEAN JOURNAL OF HEART FAILURE, 2003, 5 (03) : 253 - 259
  • [9] The predictive value of non-invasive cardiac output at rest in discharged heart failure patients
    Feola, Mauro
    Testa, Marzia
    Leto, Laura
    Rosso, Gian Luca
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 188 : 50 - 51
  • [10] Estimation of cardiac output in patients with congestive heart failure by analysis of right ventricular pressure waveforms
    Karamanoglu, Mustafa
    Bennett, Tom
    Stahlberg, Marcus
    Splett, Vincent
    Kjellstroem, Barbro
    Linde, Cecilia
    Braunschweig, Frieder
    BIOMEDICAL ENGINEERING ONLINE, 2011, 10