Salt impregnated desiccant matrices for 'open' thermochemical energy conversion and storage - Improving energy density utilisation through hygrodynamic & thermodynamic reactor design

被引:39
作者
Casey, Sean P. [1 ]
Aydin, Devrim [2 ]
Elvins, Jon [3 ]
Riffat, Saffa [4 ]
机构
[1] North Lindsey Coll, Univ Ctr, Kingsway, Scunthorpe DN17 IAJ, England
[2] Eastern Mediterranean Univ, Dept Mech Engn, TRNC Mersin 10, Famagusta, Turkey
[3] SPECIFIC, Baglan Energy Pk, Baglan SA12 7AX, Port Talbot, Wales
[4] Univ Nottingham, Fac Engn, Div Infrastructure Geomat & Architecture, Univ Pk, Nottingham NG7 2RD, England
基金
“创新英国”项目;
关键词
Salt In Matrix; Open thermal energy storage; Vermiculite; Hygrothermal; Thermochemical; SORPTION HEAT-STORAGE; SOLAR THERMAL-ENERGY; PERFORMANCE ANALYSIS; SEASONAL STORAGE; SYSTEM; BUILDINGS; ADVANCEMENTS; TECHNOLOGIES; UPGRADE; PIPE;
D O I
10.1016/j.enconman.2017.03.066
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, the performance of three nano-composite energy storage absorbents; Vermiculite-CaCl2 (SIM-3a), Vermiculite-CaCl2-LiNO3 (SIM-3f), and the desiccant Zeolite 13X were experimentally investigated for suitability to domestic scale thermal energy storage. A novel 3 kWh open thermochemical reactor consisting of new meshed tube air diffusers was built to experimentally examine performance. The results were compared to those obtained using a previously developed flatbed experimental reactor. SIM-3a has the best cyclic behaviour and thermal performance. It was found that 0.01 m(3) of SIM-3a can provide an average temperature lift of room air, Delta T = 20 degrees C over 180 min whereas for SIM-3f, Delta T< 15 degrees C was achieved. Zeolite provided high sorption heat in close approximation with SIM-3a, however, the higher desorption temperature requirements coupled with poor cyclic ability remain as obstacles to the roll out this material commercially. The study results clearly show that the concept of using perforated tubes embedded inside the heat storage material significantly improves performance by enhancing the contact surface area between air -> absorbent whilst increasing vapour diffusion. The results suggest a linear correlation between thermal performance and moisture uptake, Delta T-Delta w. Determining these operating lines will prove useful for predicting achievable temperature lift and also for effective design and control of thermochemical heat storage systems. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:426 / 440
页数:15
相关论文
共 42 条
  • [1] Closed and open thermochemical energy storage: Energy- and exergy-based comparisons
    Abedin, Ali Haji
    Rosen, Marc A.
    [J]. ENERGY, 2012, 41 (01) : 83 - 92
  • [2] [Anonymous], 2009, IEA KEY WORLD ENERGY
  • [3] [Anonymous], [No title captured]
  • [4] Aristov Y., 2016, RENEW ENERGY
  • [5] Aydin D, 2015, INT J FUT CITIES ENV, V1, P2, DOI DOI 10.1186/540984-015-0003-X
  • [6] Novel "open-sorption pipe" reactor for solar thermal energy storage
    Aydin, Devrim
    Casey, Sean P.
    Chen, Xiangjie
    Riffat, Saffa
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2016, 121 : 321 - 334
  • [7] Numerical analysis of solar-assisted seasonal 'open' thermochemical heat storage
    Aydin, Devrim
    Casey, Sean P.
    Riffat, Saffa
    [J]. INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2015, 10 (02) : 131 - 138
  • [8] Thermal performance analysis of a solar energy sourced latent heat storage
    Aydin, Devrim
    Utlu, Zafer
    Kincay, Olcay
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 50 : 1213 - 1225
  • [9] The latest advancements on thermochemical heat storage systems
    Aydin, Devrim
    Casey, Sean P.
    Riffat, Saffa
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 41 : 356 - 367
  • [10] Model of a solar-assisted heat-pump system for space heating integrating a thermal energy storage unit
    Badescu, V
    [J]. ENERGY AND BUILDINGS, 2002, 34 (07) : 715 - 726