The development of Ti alloys for dental implant with high corrosion resistance and mechanical strength

被引:47
作者
Yamazoe, Junichi
Nakagawa, Masaharu
Matono, Yoshinari
Takeuchi, Akari
Ishikawa, Kunio
机构
[1] Kyushu Univ, Fac Dent Sci, Dept Biomat, Higashi Ku, Fukuoka 8128582, Japan
[2] Kyushu Univ, Fac Dent Sci, Dept Fixed Prosthodont, Higashi Ku, Fukuoka 8128582, Japan
关键词
titanium alloy; corrosion; mechanical strength;
D O I
10.4012/dmj.26.260
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The corrosion behaviors of Ti and Ti-6Al-V, Ti-6Al-7Nb, Ti-0.5Pt, Ti-6Al-4V-0.5Pt, and Ti-6Al-7Nb-0.5Pt alloys were examined using an electrochemical analyzer in artificial saliva containing 0.1 and 0.2% NaF at a pH of 4.0. The SEM observations revealed that the surfaces of the alloys containing 0.5 wt% Pt were not affected in fluoride-containing environments, whereas the surfaces of Ti, Ti-6Al-4V, and Ti-6Al-7Nb alloys were markedly rough. In artificial saliva containing 0.1% NaF at a pH of 4.0, the amounts of Ti dissolved from the Ti, Ti-6Al-4V, and Ti-6Al-7Nb alloys were about 50 times larger than those of the alloys containing 0.5 wt% Pt. The tensile strengths of the alloys containing 0.5 wt% Pt were equal to or higher than those of pure Ti or the alloys without Pt. The Ti-0.5Pt, Ti-6Al-4V-0.5Pt, and Ti-6Al-7Nb-0.5 alloys are expected to be useful in clinical dentistry as new Ti alloys with high corrosion resistance and mechanical strength.
引用
收藏
页码:260 / 267
页数:8
相关论文
共 23 条
[1]   INFLUENCE OF FLUORIDE ON TITANIUM IN AN ACIDIC ENVIRONMENT MEASURED BY POLARIZATION RESISTANCE TECHNIQUE [J].
BOERE, G .
JOURNAL OF APPLIED BIOMATERIALS, 1995, 6 (04) :283-288
[2]   Effects of fluoride concentration and elastic tensile strain on the corrosion resistance of commercially pure titanium [J].
Huang, HH .
BIOMATERIALS, 2002, 23 (01) :59-63
[3]  
JOHANSSON BI, 1995, DENT MATER, V1, P41
[4]   Delayed fracture of beta titanium orthodontic wire in fluoride aqueous solutions [J].
Kaneko, K ;
Yokoyama, K ;
Moriyama, K ;
Asaoka, K ;
Sakai, J ;
Nagumo, M .
BIOMATERIALS, 2003, 24 (12) :2113-2120
[5]   Mechanical properties and corrosion resistance of Ti-6Al-7Nb alloy dental castings [J].
Kobayashi, E ;
Wang, TJ ;
Doi, H ;
Yoneyama, T ;
Hamanaka, H .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1998, 9 (10) :567-574
[6]   Design and mechanical properties of new β type titanium alloys for implant materials [J].
Kuroda, D ;
Niinomi, M ;
Morinaga, M ;
Kato, Y ;
Yashiro, T .
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 1998, 243 (1-2) :244-249
[7]   ACCELERATED OXIDE-GROWTH ON TITANIUM IMPLANTS DURING AUTOCLAVING CAUSED BY FLUORINE CONTAMINATION [J].
LAUSMAA, J ;
KASEMO, B ;
HANSSON, S .
BIOMATERIALS, 1985, 6 (01) :23-&
[8]   Corrosion behavior of pure titanium and titanium alloys in various concentrations of acidulated phosphate fluoride (APF) solutions [J].
Matono, Yoshinari ;
Nakagawa, Masaharu ;
Matsuya, Shigeki ;
Ishikawa, Kunio ;
Terada, Yoshihiro .
DENTAL MATERIALS JOURNAL, 2006, 25 (01) :104-112
[9]  
Mimura H., 1996, JPN J DENT MAT DEV, V15, P283
[10]   ELECTRONIC STATES OF CATHODES OF TI-BASED ALLOYS IN AQUEOUS CORROSION [J].
MORISHITA, M ;
CHIKUDA, M ;
ASHIDA, Y ;
MORINAGA, M ;
YUKAWA, N ;
ADACHI, H .
JOURNAL OF THE JAPAN INSTITUTE OF METALS, 1990, 54 (12) :1369-1375