Behaviour and design of cold-formed steel built-up section beams with different screw arrangements

被引:78
作者
Wang, Liping [1 ]
Young, Ben [2 ]
机构
[1] Cent South Univ, Sch Civil Engn, Changsha, Hunan, Peoples R China
[2] Univ Hong Kong, Dept Civil Engn, Pokfulam Rd, Hong Kong, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
Buckling; Built-up beams; Direct strength method; Experiments; Finite element; Screw spacing; FLEXURAL STRENGTH; I-SECTION; BOX;
D O I
10.1016/j.tws.2018.06.022
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An experimental and numerical investigation of cold-formed steel built-up beams with different screw arrangements is presented in this paper. A total of 35 beams were tested under four-point bending with different screw arrangements in the moment span. The built-up sections were assembled using self-tapping screws from either two lipped channels connected back-to-back at the web to form an open section or two plain channels connected face-to-face at the flanges to form a closed section. Finite element (FE) models have been developed and validated against the test results for the built-up open section beams and built-up closed section beams, respectively. It is shown that the FE models can accurately predict the behaviour of cold-formed steel built-up beams with different screw arrangements. A parametric study on built-up beams with larger span and various screw spacing was further carried out using the verified FE models. The test and numerical results were compared with the design strengths predicted by the direct strength method (DSM) for cold-formed steel structures, with contingent considerations of the screws when determining the elastic buckling moments in the finite strip analysis. A reliability analysis was performed to evaluate the reliability of the current DSM equations. It is shown that the current DSM equations can predict the design strengths of built-up open section beams well in this study, with the assumption that the strength of the built-up section is the sum of two component profiles. However, the design equations for local buckling strength are generally conservative for the built-up closed section beams failed by local buckling. Meanwhile, the design equations for lateral-torsional buckling (LTB) strength cannot be directly used for the built-up closed section beams with relatively large screw spacing that failed by LTB with cross section distortion or separation of two component channels. It should be noted that LTB mode with cross section distortion was found in built-up closed section beams with large screw spacing. A modified design rule based on DSM is then proposed, which is shown to improve the accuracy of the predicted strengths. Moreover, the maximum longitudinal screw spacing for built-up closed section beams was also recommended for design practice.
引用
收藏
页码:16 / 32
页数:17
相关论文
共 22 条
[1]  
[Anonymous], 2016, AISI S100-16
[2]  
[Anonymous], 2012, ABAQUS STANDARD USER
[3]  
[Anonymous], 2014, THESIS
[4]  
AS/NZS, 2005, AS/NZS 4600:2005
[5]  
ASCE/SEI 710, 2010, ASCE 7-10
[6]  
Australian/New Zealand Standard, 2002, 117002002 ASNZS
[7]   Laser welded built-up cold-formed steel beams: Experimental investigations [J].
Landolfo, R. ;
Mammana, O. ;
Portioli, F. ;
Di Lorenzo, G. ;
Guerrieri, M. R. .
THIN-WALLED STRUCTURES, 2008, 46 (7-9) :781-791
[8]   Investigation on flexural strength of cold-formed thin-walled steel beams with built-up box section [J].
Li, Ying-Lei ;
Li, Yuan-Qi ;
Shen, Zu-Yan .
THIN-WALLED STRUCTURES, 2016, 107 :66-79
[9]   Ultimate load-carrying capacity of cold-formed thin-walled columns with built-up box and I section under axial compression [J].
Li, Yuanqi ;
Li, Yinglei ;
Wang, Shukun ;
Shen, Zuyan .
THIN-WALLED STRUCTURES, 2014, 79 :202-217
[10]  
Li Z., 2010, 20th International Specialty Conference on Cold-Formed Steel Structures - Recent Research and Developments in Cold-Formed Steel Design and Construction, P17