Chemically modified carbon-based electrodes for the determination of paracetamol in drugs and biological samples

被引:62
作者
Boumya, Wafaa [1 ,2 ]
Taoufik, Nawal [1 ]
Achak, Mounia [2 ,3 ]
Barka, Noureddine [3 ]
机构
[1] Sultan Moulay Slimane Univ Beni Mellal, Res Grp Environm Sci & Appl Mat SEMA, BP 145, Khouribga 25000, Morocco
[2] Chouaib Doukkali Univ, Lab Sci Ingn Energie, Ecole Natl Sci Appl, El Jadida, Morocco
[3] Mohammed VI Polytech Univ, Chem & Biochem Sci, CBS, Green Proc Engn, Ben Guerir, Morocco
关键词
Paracetamol; Electrochemical sensors; Modified electrodes; Pharmaceutical samples; SIMULTANEOUS VOLTAMMETRIC DETERMINATION; REDUCED GRAPHENE OXIDE; SIMULTANEOUS ELECTROCHEMICAL DETERMINATION; NANOCOMPOSITE MODIFIED ELECTRODE; DOPED DIAMOND ELECTRODE; PASTE ELECTRODE; ASCORBIC-ACID; SENSITIVE DETERMINATION; CERAMIC ELECTRODE; PHARMACEUTICAL FORMULATIONS;
D O I
10.1016/j.jpha.2020.11.003
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Paracetamol is a non-steroidal, anti-inflammatory drug widely used in pharmaceutical applications for its sturdy, antipyretic and analgesic action. However, an overdose of paracetamol can cause fulminant hepatic necrosis and other toxic effects. Thus, the development of advantageous analytical tools to detect and determine paracetamol is required. Due to simplicity, higher sensitivity and selectivity as well as costefficiency, electrochemical sensors were fully investigated in last decades. This review describes the advancements made in the development of electrochemical sensors for the paracetamol detection and quantification in pharmaceutical and biological samples. The progress made in electrochemical sensors for the selective detection of paracetamol in the last 10 years was examined, with a special focus on highly innovative features introduced by nanotechnology. As the literature is rather extensive, we tried to simplify this work by summarizing and grouping electrochemical sensors according to the by which manner their substrates were chemically modified and the analytical performances obtained. ? 2020 Xi'an Jiaotong University. Production and hosting by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:138 / 154
页数:17
相关论文
共 134 条
[1]   CARBON PASTE ELECTRODES [J].
ADAMS, RN .
ANALYTICAL CHEMISTRY, 1958, 30 (09) :1576-1576
[2]   Sensitive Detection of Acetaminophen with Graphene-Based Electrochemical Sensor [J].
Adhikari, Bal-Ram ;
Govindhan, Maduraiveeran ;
Chen, Aicheng .
ELECTROCHIMICA ACTA, 2015, 162 :198-204
[3]   Facile simultaneous electrochemical determination of codeine and acetaminophen in pharmaceutical samples and biological fluids by graphene CoFe2O4 nancomposite modified carbon paste electrode [J].
Afkhami, Abbas ;
Khoshsafar, Hosein ;
Bagheri, Hasan ;
Madrakian, Tayyebeh .
SENSORS AND ACTUATORS B-CHEMICAL, 2014, 203 :909-918
[4]   Preparation of NiFe2O4/graphene nanocomposite and its application as a modifier for the fabrication of an electrochemical sensor for the simultaneous determination of tramadol and acetaminophen [J].
Afkhami, Abbas ;
Khoshsafar, Hosein ;
Bagheri, Hasan ;
Madrakian, Tayyebeh .
ANALYTICA CHIMICA ACTA, 2014, 831 :50-59
[5]   Deposition of nanomaterials: A crucial step in biosensor fabrication [J].
Ahmad, Rafiq ;
Wolfbeis, Otto S. ;
Hahn, Yoon-Bong ;
Alshareef, Husam N. ;
Torsi, Luisa ;
Salama, Khaled N. .
MATERIALS TODAY COMMUNICATIONS, 2018, 17 :289-321
[6]   Enhanced amperometric detection of paracetamol by immobilized cobalt ion on functionalized MWCNTs - Chitosan thin film [J].
Akhter, Shamima ;
Basirun, Wan Jefrey ;
Alias, Yatimah ;
Johan, Mohd Rafie ;
Bagheri, Samira ;
Shalauddin, Md ;
Ladan, Magaji ;
Anuar, Nadzirah Sofia .
ANALYTICAL BIOCHEMISTRY, 2018, 551 :29-36
[7]   Amperometric Determination of Acetaminophen (paracetamol) Using Graphene Oxide Modified Glassy Carbon Electrode [J].
Alagarsamy, Periyalagan ;
Settu, Ramki ;
Chen, Shen-Ming ;
Chen, Tse-Wei ;
Hong, In-Seok ;
Rao, Mettu Mallikarjuna .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (08) :7930-7938
[8]   Simultaneous electrochemical determination of dopamine and acetaminophen using multiwall carbon nanotubes modified glassy carbon electrode [J].
Alothman, Zeid Abdullah ;
Bukhari, Nausheen ;
Wabaidur, Saikh Mohammad ;
Haider, Sajjad .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 146 (01) :314-320
[9]   Fabrication of platinum nitrogen-doped graphene nanocomposite modified electrode for the electrochemical detection of acetaminophen [J].
Anuar, Nadzirah Sofia ;
Basirun, Wan Jeffrey ;
Ladan, Magaji ;
Shalauddin, Md. ;
Mehmood, Muhammad Shahid .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 266 :375-383
[10]   Development of a microcomposite with single-walled carbon nanotubes and Nd2O3 for determination of paracetamol in pharmaceutical dosage by adsorptive voltammetry [J].
Arancibia, Veronica ;
Penagos-Llanos, Johisner ;
Nagles, Edgar ;
Garcia-Beltran, Olimpo ;
Hurtado, John J. .
JOURNAL OF PHARMACEUTICAL ANALYSIS, 2019, 9 (01) :62-69