Measurement of the effective electric field radius on digital ion trap spectrometer

被引:3
|
作者
Xu, Fuxing [1 ]
Wang, Weimin [1 ]
Jin, Liuyu [1 ]
Qian, Bingjun [1 ]
Ding, Chuan-Fan [1 ]
机构
[1] Ningbo Univ, Sch Mat Sci & Chem Engn, Inst Mass Spectrometry, Key Lab Adv Mass Spectrometry & Mol Anal Zhejiang, Ningbo 315211, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
COLLISION-INDUCED-DISSOCIATION; MASS-SPECTROMETRY; ACTIVATION; PERFORMANCE; ANALYZER;
D O I
10.1039/d1an00468a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The effective electric field radius is a fundamental parameter of ion traps, and it has a significant influence on ion-trapping capability, signal intensity, mass range and some other properties of the ion trap. For a quadrupole ion trap built with ideal hyperbolic electrodes, its effective electric field radius can be obtained by its geometrical size, while it is very difficult to obtain the effective electric field radius for a non-hyperbolic ion trap. In this study, the effective electric field radius of a linear ion trap and some ceramic rectilinear ion traps (cRITs) were investigated via the digital ion trap technology. The dipole frequency of supplementary AC for excitation was locked at a certain value of the main RF trapping wave, and the characteristic q values for excitation could be determined accordingly. The q values could be further used to calculate the effective electric field radius through theoretical calculations. A linear equation had been fitted between the q values for excitation and the square of period T-2 through experiments subsequently. The relative deviation between the measured electric field radius and the simulative electric field radius is less than 2%. The simulation results and experimental validation show that the approach has predictive power for modeling and measuring the effective field radius of non-hyperbolic ion traps. It is certainly significant for further understanding the performances of non-hyperbolic quadrupole systems.
引用
收藏
页码:3810 / 3817
页数:8
相关论文
共 50 条
  • [1] A simulation study of the digital ion trap mass spectrometer
    Ding, L
    Sudakov, M
    Kumashiro, S
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 221 (02) : 117 - 138
  • [2] Ion motion in the rectangular wave quadrupole field and digital operation mode of a quadrupole ion trap mass spectrometer
    Ding, L.
    Kumashiro, S.
    Zhenkong Kexue yu Jishu Xuebao/Vacuum Science and Technology, 2001, 21 (03): : 176 - 181
  • [3] Ion motion in the rectangular wave quadrupole field and digital operation mode of a quadrupole ion trap mass spectrometer
    Ding, L
    Kumashiro, S
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (01) : 3 - 8
  • [4] Electron capture dissociation in a digital ion trap mass spectrometer
    Ding, L
    Brancia, FL
    ANALYTICAL CHEMISTRY, 2006, 78 (06) : 1995 - 2000
  • [5] Design and Performance of Digital Rectilinear Ion Trap Mass Spectrometer
    Li Xiao-Xu
    Jiang Gong-Yu
    Ding Li
    Wang Yuan-Yuan
    Ding Chuan-Fan
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (09) : 1397 - 1402
  • [6] A digital ion trap mass spectrometer coupled with atmospheric pressure ion sources
    Ding, L
    Sudakov, M
    Brancia, FL
    Giles, R
    Kumashiro, S
    JOURNAL OF MASS SPECTROMETRY, 2004, 39 (05): : 471 - 484
  • [7] A hand-portable digital linear ion trap mass spectrometer
    Xue, Bing
    Sun, Lulu
    Huang, Zhengxu
    Gao, Wei
    Fan, Rongrong
    Cheng, Ping
    Ding, Li
    Ma, Li
    Zhou, Zhen
    ANALYST, 2016, 141 (19) : 5535 - 5542
  • [8] The Effective Temperature of Ions Stored in a Linear Quadrupole Ion Trap Mass Spectrometer
    Donald, William A.
    Khairallah, George N.
    O'Hair, Richard A. J.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2013, 24 (06) : 811 - 815
  • [9] COLLISIONAL AND ELECTRIC-FIELD IONIZATION OF LASER-PREPARED RYDBERG STATES IN AN ION TRAP MASS-SPECTROMETER
    RAMSEY, JM
    WHITTEN, WB
    GOERINGER, DE
    BUCKLEY, BT
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1991, (114): : 301 - 306
  • [10] Effect of high voltage module performance on digital ion trap mass spectrometer
    Fan, Rong-Rong
    Xue, Bing
    Sun, Lu-Lu
    Dong, Jun-Guo
    Gao, Wei
    Huang, Zheng-Xu
    Cheng, Ping
    Zhou, Zhen
    Journal of Chinese Mass Spectrometry Society, 2015, 36 (02) : 97 - 103