Impact of chilled ceiling on indoor air distribution in a room with mixing ventilation

被引:12
作者
Wu, Xiaozhou [1 ]
Gao, Jie [2 ]
Lv, Pin [1 ]
Wang, Haichao [1 ]
Wang, Shugang [1 ]
Wang, Fenghao [3 ]
机构
[1] Dalian Univ Technol, Sch Civil Engn, Dalian, Peoples R China
[2] Dalian Univ, Coll Civil Engn & Architecture, Dalian, Peoples R China
[3] Xi An Jiao Tong Univ, Sch Human Settlements & Civil Engn, Xian, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
RADIANT COOLING SYSTEMS; THERMAL ENVIRONMENT; MIXED CONVECTION; OFFICE; DISPERSION; PARTICLES; QUALITY; COMFORT;
D O I
10.1080/23744731.2019.1691421
中图分类号
O414.1 [热力学];
学科分类号
摘要
A mixing ventilation (MV) system integrated with a chilled ceiling (CC) cooling system will be a potential advanced heating, ventilation and air conditioning (HVAC) system in the modern buildings. This paper presented an experimental study concerning the effect of CC on the indoor air distribution with MV when the internal and external sensible cooling loads changed. The vertical distributions of indoor air temperature, air velocity and contaminant (CO2) concentration were evaluated by the vertical air temperature difference, turbulence intensity and contaminant removal effectiveness, respectively. The results showed that when chilled ceiling surface temperature ranged from 17.0 degrees C to 26.0 degrees C, the average vertical air temperature difference, turbulence intensity and contaminant removal effectiveness were 0.2 degrees C-0.4 degrees C, 30%-36% and 0.6-0.84 when both internal and external sensible cooling loads were 41.5 W/m(2). Moreover, the ranges of these evaluation indices varied slightly when the internal or external sensible cooling load increased from 41.5 W/m(2) to 69.5 W/m(2). Hence, the chilled ceiling had a slight impact on the indoor air distribution in a room with mixing ventilation. It is interestingly found that the small vertical air temperature difference coincided with the large turbulence intensity and contaminant removal effectiveness with different internal or external cooling loads.
引用
收藏
页码:366 / 376
页数:11
相关论文
共 30 条
  • [1] [Anonymous], 7730 ISO
  • [2] Indoor air quality in rooms with cooled ceilings. Mixing ventilation or rather displacement ventilation?
    Behne, M
    [J]. ENERGY AND BUILDINGS, 1999, 30 (02) : 155 - 166
  • [3] Ventilation control strategy using low-dimensional linear ventilation models and artificial neural network
    Cao, Shi-Jie
    Ren, Chen
    [J]. BUILDING AND ENVIRONMENT, 2018, 144 : 316 - 333
  • [4] Study on the impacts of human walking on indoor particles dispersion using momentum theory method
    Cao, Shi-Jie
    Cen, Dongdong
    Zhang, Weirong
    Feng, Zhuangbo
    [J]. BUILDING AND ENVIRONMENT, 2017, 126 : 195 - 206
  • [5] Influence of turbulent boundary conditions on RANS simulations of pollutant dispersion in mechanically ventilated enclosures with transitional slot Reynolds number
    Cao, Shi-Jie
    Meyers, Johan
    [J]. BUILDING AND ENVIRONMENT, 2013, 59 : 397 - 407
  • [6] Experimental and numerical analysis of air and radiant cooling systems in offices
    Corgnati, S. P.
    Perino, M.
    Fracastoro, G. V.
    Nielsen, P. V.
    [J]. BUILDING AND ENVIRONMENT, 2009, 44 (04) : 801 - 806
  • [7] Influence of air change rates on indoor CO2 stratification in terms of Richardson number and vorticity
    Deng, Hua-Yan
    Feng, Zhuangbo
    Cao, Shi-Jie
    [J]. BUILDING AND ENVIRONMENT, 2018, 129 : 74 - 84
  • [8] Energy Efficiency Economics and Policy
    Gillingham, Kenneth
    Newell, Richard G.
    Palmer, Karen
    [J]. ANNUAL REVIEW OF RESOURCE ECONOMICS, 2009, 1 : 597 - 619
  • [9] An experimental investigation into stratum ventilation for the cooling of an office with asymmetrically distributed heat gains
    Huan, C.
    Wang, F. H.
    Lin, Zhang
    Wu, X. Z.
    Ma, Z. J.
    Wang, Z. H.
    Zhang, L. H.
    [J]. BUILDING AND ENVIRONMENT, 2016, 110 : 76 - 88
  • [10] Impact of mixed convection on ceiling radiant cooling panel capacity
    Jeong, JW
    Mumma, SA