A mitochondria-targetable fluorescent probe for detection of bisulfite in living cells

被引:8
|
作者
Guo, Xiao [1 ]
Zhu, Wei-Jin [1 ]
Wei, Xue-Rui [2 ]
Xu, Yu-Jie [2 ]
Sun, Ru [1 ]
Ge, Jian-Feng [1 ,3 ]
机构
[1] Soochow Univ, Coll Chem Chem Engn & Mat Sci, 199 RenAi Rd, Suzhou 215123, Peoples R China
[2] Soochow Univ, Jiangsu Higher Educ Inst, Collaborat Innovat Ctr Radiat Med, State Key Lab Radiat Med & Protect,Sch Radiat Med, Suzhou 215123, Peoples R China
[3] Chinese Acad Sci, Suzhou Inst Biomed Engn & Technol, Jiangsu Key Lab Med Opt, Suzhou 215163, Peoples R China
基金
中国国家自然科学基金;
关键词
SO2; DERIVATIVES; SELECTIVE DETECTION; RATIOMETRIC DETECTION; SULFUR-DIOXIDE; SULFITE; PLATFORM; SENSORS; SAMPLES; ANIONS; ESIPT;
D O I
10.1039/c8ay01543k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new colorimetric semi-cyanine fluorescent probe (3) based on benzo[g]indolium was designed and prepared. Probe 3 exhibited a clear OFF-ON fluorescence response at 460 nm toward HSO3- (0-8.0 eq.) within a short response time (3 min). In addition, probe 3 had good selectivity and competitiveness, with excellent sensitivity and a low detection limit (4.4 nM). The detection mechanism relied on nucleophilic HSO3- attacking the C?C double bond in a 1,4-nucleophilic addition reaction. Importantly, the confocal fluorescence results indicated that probe 3 targeted mitochondria and could detect HSO3- in living cells.
引用
收藏
页码:3872 / 3877
页数:6
相关论文
共 50 条
  • [41] A mitochondria-targeted fluorescent probe for ratiometric detection of hypochlorite in living cells
    Yahui Chen
    Tingwen Wei
    Zhijie Zhang
    Wei Zhang
    Jing Lv
    Tiantian Chen
    Bo Chi
    Fang Wang
    Xiaoqiang Chen
    Chinese Chemical Letters, 2017, 28 (10) : 1957 - 1960
  • [42] A mitochondria-targeted fluorescent probe for ratiometric detection of hypochlorite in living cells
    Chen, Yahui
    Wei, Tingwen
    Zhang, Zhijie
    Zhang, Wei
    Lv, Jing
    Chen, Tiantian
    Chi, Bo
    Wang, Fang
    Chen, Xiaoqiang
    CHINESE CHEMICAL LETTERS, 2017, 28 (10) : 1957 - 1960
  • [43] Mitochondria-Targetable Near-Infrared Fluorescent Probe for Visualization of Hydrogen Peroxide in Lung Injury, Liver Injury, and Tumor Models
    Zan, Qi
    Zhao, Kunyi
    Li, Ruijin
    Yang, Yongming
    Yang, Xihua
    Li, Wenzhong
    Zhang, Gangli
    Dong, Chuan
    Shuang, Shaomin
    Fan, Li
    ANALYTICAL CHEMISTRY, 2024, 96 (26) : 10488 - 10495
  • [44] Mitochondria-targetable carbon quantum dots for differentiating cancerous cells from normal cells
    Gao, Ge
    Jiang, Yao-Wen
    Yang, Jingjing
    Wu, Fu-Gen
    NANOSCALE, 2017, 9 (46) : 18368 - 18378
  • [45] Naphthalene dianhydride based selective detection targetable fluorescent probe for monitoring exogenous Iron in living cells
    Rohini, Gandhaveeti
    Ramaiah, Konakanchi
    Sreekanth, Anandaram
    TETRAHEDRON LETTERS, 2018, 59 (43) : 3858 - 3862
  • [46] Tetrahydro[5]helicene-based fluorescent probe for rapid and sensitive detection of bisulfite in living cells
    Wang, Kun-Peng
    Lei, Yang
    Sun, Ying
    Zhang, Qingyang
    Chen, Shaojin
    Zhang, Qi
    Hu, Hai-Yu
    Hu, Zhi-Qiang
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 273 : 1487 - 1494
  • [47] Mitochondria-Immobilized Fluorescent Probe for the Detection of Hypochlorite in Living Cells, Tissues, and Zebrafishes
    Li, Meng-Yang
    Li, Kun
    Liu, Yan-Hong
    Zhang, Hong
    Yu, Kang-Kang
    Liu, Xin
    Yu, Xiao-Qi
    ANALYTICAL CHEMISTRY, 2020, 92 (04) : 3262 - 3269
  • [48] A mitochondria-targeting ratiometric fluorescent probe for the detection of sulfur dioxide in living cells
    Lu, Yaru
    Dong, Baoli
    Song, Wenhui
    Sun, Yaru
    Mehmood, Abdul Hadi
    Lin, Weiying
    NEW JOURNAL OF CHEMISTRY, 2020, 44 (28) : 11988 - 11992
  • [49] A mitochondria-targeted turn-on fluorescent probe for the detection of glutathione in living cells
    Zhang, Jian
    Bao, Xiaolong
    Zhou, Junliang
    Peng, Fangfang
    Ren, Hang
    Dong, Xiaochun
    Zhao, Weili
    BIOSENSORS & BIOELECTRONICS, 2016, 85 : 164 - 170
  • [50] A colorimetric and ratiometric fluorescent probe for highly selective detection of glutathione in the mitochondria of living cells
    Qi, Sujie
    Liu, Weimin
    Zhang, Panpan
    Wu, Jiasheng
    Zhang, Hongyan
    Ren, Haohui
    Ge, Jiechao
    Wang, Pengfei
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 270 : 459 - 465