Advances in trace element analysis of silicon wafer surfaces by vapor phase decomposition (VPD) and inductively coupled plasma mass spectrometry (ICP-MS)

被引:20
|
作者
Krushevska, A [1 ]
Tan, S [1 ]
Passer, M [1 ]
Liu, XR [1 ]
机构
[1] ChemTrace Corp, Hayward, CA 94545 USA
关键词
D O I
10.1039/b001578o
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The vapor phase decomposition (VPD) technique is used to dissolve the silicon oxide layer on a Si wafer surface by exposing the wafer to HF vapor. After VPD, the hydrophobic Si wafer surface is scanned with an acidic droplet of solution to extract the surface trace metals. ICP-MS is applied for the determination of metals in the droplet of solution. Matrix effects resulting from the formation of polyatomic species are investigated. The molecular interferences from the presence of different levels of Si concentration left after VPD are investigated. The interference of F on Co-59 is found to be negligible and controllable. They are also insignificant for the isotopes of Ga, Cu, Ge and Ni. However, for Ti-47, Zn-68 and Ca-44, pronounced matrix effects are observed. A procedure for reducing Si concentration resulting from thick oxide films is carried out and optimum ICP-MS parameters are chosen for the measurement of these samples. Instrumental and method detection limits for 35 elements of interest are determined and provided in this study. Spike recovery for these 35 elements is also performed and the accuracy of the method is confirmed for 34 elements. Silver recovery is poor due to the reduction of this element on the silicon surface. An alternative extraction solution containing HNO3 and HCl is used to collect Ag from the Si wafer surface.
引用
收藏
页码:1211 / 1216
页数:6
相关论文
共 50 条
  • [1] Improving the detection limits for vapor phase decomposition-inductively coupled plasma mass spectrometry (VPD-ICP-MS) analysis
    Ferrero, EJ
    Posey, D
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (09) : 1194 - 1201
  • [2] Minor and Trace Element Analysis in Breast Milk Using Inductively Coupled Plasma Mass Spectrometry (ICP-MS)
    Liuchun Yang
    Meng Zhang
    Shen Lin
    Dengyun Chen
    Minghui Zheng
    Microchimica Acta, 2003, 142 : 85 - 88
  • [3] Minor and trace element analysis in breast milk using Inductively Coupled Plasma Mass Spectrometry (ICP-MS)
    Yang, LC
    Zhang, M
    Lin, S
    Chen, DY
    Zheng, MH
    MICROCHIMICA ACTA, 2003, 142 (1-2) : 85 - 88
  • [4] Trace metal analysis using inductively coupled plasma-mass spectrometry (ICP-MS).
    Lee, S
    Oh, H
    Choi, Y
    Kim, J
    Kim, S
    CLINICAL CHEMISTRY, 2004, 50 (06) : A58 - A58
  • [5] APPLICATION OF VAPOR-PHASE DECOMPOSITION TECHNIQUES (VPD/AAS AND ICP-MS) FOR TRACE-ELEMENT ANALYSIS IN OXIDE COATINGS ON SILICON
    TAN, SH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 99 (1-4): : 458 - 461
  • [6] Trace element concentrations in chylous pleural effusions - Determination by inductively coupled plasma mass spectrometry (ICP-MS)
    Domei, W
    Gossler, W
    Krachler, M
    Irgolic, KJ
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (03) : A388 - A388
  • [7] MULTIELEMENT TRACE ANALYSIS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY (ICP-MS) - CAPABILITIES AND LIMITATIONS
    GRAY, AL
    CHEMIA ANALITYCZNA, 1990, 35 (1-3): : 59 - 70
  • [8] Trace element analysis in some Salvia species by inductively coupled plasma-mass spectrometry (ICP-MS) and chemometric approach
    Tunay, Zeki
    Yener, Ismail
    Oral, Elif Varhan
    Demirkoz, Asli Barla
    Tokul-Olmez, Ozge
    Firat, Mehmet
    Ozturk, Mehmet
    Aydin, Isil
    Aydin, Firat
    Ertas, Abdulselam
    JOURNAL OF RESEARCH IN PHARMACY, 2020, 24 (02): : 297 - 309
  • [9] Using VPD ICP-MS to monitor trace metals on unpatterned wafer surfaces
    Settembre, G
    Debrah, E
    MICRO, 1998, 16 (06): : 79 - +
  • [10] Determination of trace elements in marine plankton by inductively coupled plasma mass spectrometry (ICP-MS)
    Z. Arslan
    N. Ertas
    J. F. Tyson
    P. C. Uden
    E. R. Denoyer
    Fresenius' Journal of Analytical Chemistry, 2000, 366 : 273 - 282