共 50 条
Development of microwave-enhanced spark-induced breakdown spectroscopy
被引:45
作者:
Ikeda, Yuji
[1
]
Moon, Ahsa
[1
]
Kaneko, Masashi
[1
]
机构:
[1] Imagineering Inc, Nada Ku, Kobe, Hyogo 6570038, Japan
关键词:
LASER-INDUCED PLASMA;
HEAVY-METALS;
PULSE LASER;
AIR;
RATIO;
FLAMES;
LIBS;
D O I:
10.1364/AO.49.000C95
中图分类号:
O43 [光学];
学科分类号:
070207 ;
0803 ;
摘要:
We propose microwave-enhanced spark-induced breakdown spectroscopy with the same measurement and analysis processes as in laser-induced breakdown spectroscopy, but with a different plasma generation mechanism. The size and lifetime of the plasma generated can contribute to increased measurement accuracy and expand its applicability to industrial measurement, such as an exhaust gas analyzer for automobile engine development and its regulation, which has been hard to operate by laser at an engineering evaluation site. The use of microwaves in this application helps lower the cost, reduce the system size, and increase the ease of operation to make it commercially viable. A microwave frequency of 2: 45 GHz was used to enhance the volume and lifetime of the plasma at atmospheric condition even at elevated pressure. (C) 2010 Optical Society of America
引用
收藏
页码:C95 / C100
页数:6
相关论文
共 50 条