In vitro corrosion resistance and cytocompatibility of nano-hydroxyapatite reinforced Mg-Zn-Zr composites

被引:133
作者
Ye, Xinyu [2 ]
Chen, Minfang [1 ,2 ]
Yang, Meng [2 ]
Wei, Jun [3 ]
Liu, Debao [2 ,4 ]
机构
[1] Tianjin Key Lab Photoelectr Mat & Devices, Tianjin 300384, Peoples R China
[2] Tianjin Univ Technol, Sch Mat Sci & Engn, Tianjin 300384, Peoples R China
[3] Singapore Inst Mfg Technol, Singapore 638075, Singapore
[4] Tianjin Univ Technol, Key Lab Display Mat & Photoelectr Devices, Minist Educ, Tianjin 300384, Peoples R China
关键词
MAGNESIUM; ALLOYS; BIOCOMPATIBILITY;
D O I
10.1007/s10856-009-3954-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Due to good biocompatibility and mechanical properties, magnesium (Mg) and its alloys are considered promising degradable materials for orthopedic applications. In this work, a Mg metal matrix composite (MMC) was fabricated using Mg-2.9Zn-0.7Zr alloy as the matrix and 1 wt% nano-hydroxyapatite (n-HA) particles as reinforcements. In vitro corrosion behavior and cytocompatibility of a Mg-Zn-Zr/n-HA composite and a Mg-Zn-Zr alloy were investigated. In contrast with the Mg-Zn-Zr alloy, the MMC has better properties. The average corrosion rate of MMC is 0.75 mm/yr after immersion in simulated body fluid (SBF) for 20 days, and the surface of MMC is covered with white Ca-P precipitates. The electrochemical test results show that the corrosion potential (E (corr)) of MMC increases to -1.615 V and its polarization resistance (R (p)) is 2.56 K Omega with the addition of n-HA particles. The co-cultivation of MMC with osteoblasts results in the adhesion and proliferation of cells on the surface of the composite. The maximum cell density is calculated to be (1.85 +/- 0.15) x 10(4)/l after 5 days of co-culture with osteoblasts. The average cell numbers for two groups after culturing for 3 and 5 days (P < 0.05) are significantly different. All the results demonstrate that the Mg-Zn-Zr/n-HA composite can be potentially used as biodegradable bone fixation material.
引用
收藏
页码:1321 / 1328
页数:8
相关论文
共 23 条
[1]   Neuropathology of aluminum toxicity in rats (glutamate and GABA impairment) [J].
Abd El-Rahman, SS .
PHARMACOLOGICAL RESEARCH, 2003, 47 (03) :189-194
[2]   Characterization and corrosion studies of fluoride conversion coating on degradable Mg implants [J].
Chiu, K. Y. ;
Wong, M. H. ;
Cheng, F. T. ;
Man, H. C. .
SURFACE & COATINGS TECHNOLOGY, 2007, 202 (03) :590-598
[3]  
CUI X, 2006, CHIN J ORTHOP, V14, P1159
[4]   Organic-inorganic surface modifications for titanium implant surfaces [J].
de Jonge, Lise T. ;
Leeuwenburgh, Sander C. G. ;
Wolke, Joop G. C. ;
Jansen, John A. .
PHARMACEUTICAL RESEARCH, 2008, 25 (10) :2357-2369
[5]  
[高惠敏 Gao Huimin], 2004, [功能高分子学报, Journal of Functional Polymer], V17, P281
[6]   In vitro corrosion and biocompatibility of binary magnesium alloys [J].
Gu, Xuenan ;
Zheng, Yufeng ;
Cheng, Yan ;
Zhong, Shengping ;
Xi, Tingfei .
BIOMATERIALS, 2009, 30 (04) :484-498
[7]  
Gurrappa I, 2001, CORROS PREVENT CONTR, V48, P23
[8]  
[黄晶晶 HUANG Jingjing], 2006, [材料导报, Materials Review], V20, P67
[9]   How useful is SBF in predicting in vivo bone bioactivity? [J].
Kokubo, T ;
Takadama, H .
BIOMATERIALS, 2006, 27 (15) :2907-2915
[10]  
Kong Li-Jun, 2007, Sheng Wu Gong Cheng Xue Bao, V23, P262, DOI 10.1016/S1872-2075(07)60023-5