VISUALIZATION OF ANTERIOR SKULL BASE DEFECTS WITH INTRAOPERATIVE CONE-BEAM CT

被引:8
|
作者
Bachar, Gideon [1 ]
Barker, Emma [1 ]
Chan, Harley [2 ]
Daly, Michael J. [2 ]
Nithiananthan, Sajendra [2 ,3 ]
Vescan, Al [4 ]
Irish, Jonathan C. [1 ]
Siewerdsen, Jeffrey H. [2 ,3 ,5 ]
机构
[1] Princess Margaret Hosp, Dept Surg Oncol, Dept Otolaryngol Head & Neck Surg, Toronto, ON M4X 1K9, Canada
[2] Univ Toronto, Inst Med Sci, Univ Hlth Network, Ontario Canc Inst,Princess Margaret Hosp, Toronto, ON M5S 1A1, Canada
[3] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
[4] Mt Sinai Hosp, Dept Otolaryngol Head & Neck Surg, Toronto, ON M5G 1X5, Canada
[5] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD USA
来源
HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK | 2010年 / 32卷 / 04期
基金
美国国家卫生研究院;
关键词
cone-beam CT; sinus; skull base; surgery; intraoperative; imaging; cerebrospinal fluid (CSF); CEREBROSPINAL-FLUID RHINORRHEA; HIGH-RESOLUTION CT; COMPUTED-TOMOGRAPHY; MR CISTERNOGRAPHY; DIAGNOSIS; SURGERY; FISTULA; GUIDANCE; PANEL; ARM;
D O I
10.1002/hed.21219
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Background. The role of cone-beam CT (CBCT) in demonstrating anterior skull base defects (ASBDs), differing in size and location, was investigated. The study was designed to describe the potential advantage of CBCT in the setting of an intraoperative cerebrospinal fluid (CSF) leak. Methods. In all, 120 ASBD were evaluated in 5 cadaver heads. Orthogonal and oblique slices were reconstructed. Observer studies assessed the visibility of ASBD in each location as a function of defect size. Results. For 1-, 2-, and 4-mm defects, the percentage that were undetectable ranged from 20% to 33%, 0% to 14%, and 0% to 5%, respectively. Confident breach detection increased with defect size and was most challenging in the lateral lamella and cribriform. CBCT permitted confident detection of ASBD as small as about 2 mm in the fovea ethmoidalis and planum. Oblique views were found to be superior to orthogonal planes. Conclusions. The ability to identify ASBD depended on the size and location of defect. Oblique viewing planes were optimal for ASBD visualization. (C) 2009 Wiley Periodicals, Inc. Head Neck 32: 504-512, 2010
引用
收藏
页码:504 / 512
页数:9
相关论文
共 50 条
  • [31] Detection of simulated periodontal defects using cone-beam CT and digital intraoral radiography
    Bayat, Samaneh
    Talaeipour, Ahmad Reza
    Sarlati, Fatemeh
    DENTOMAXILLOFACIAL RADIOLOGY, 2016, 45 (06)
  • [32] Cone-beam CT reconstruction for planar object
    Liu, Tong
    NDT & E INTERNATIONAL, 2012, 45 (01) : 9 - 15
  • [33] Geometric calibration of a mobile C-arm for intraoperative cone-beam CT
    Daly, M. J.
    Siewerdsen, J. H.
    Cho, Y. B.
    Jaffray, D. A.
    Irish, J. C.
    MEDICAL PHYSICS, 2008, 35 (05) : 2124 - 2136
  • [34] Intraoperative verification of resection margins of maxillary malignancies by cone-beam computed tomography
    Ivashchenko, O.
    Pouw, B.
    de Witt, J. K.
    Koudounarakis, E.
    Nijkamp, J.
    van Veen, R. L. P.
    Ruers, T. J. M.
    Karakullukcu, B. M.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2019, 57 (02): : 174 - 181
  • [35] Dose and Image Quality Evaluation of a Dedicated Cone-Beam CT System for High-Contrast Neurologic Applications
    Yu, Lifeng
    Vrieze, Thomas J.
    Bruesewitz, Michael R.
    Kofler, James M.
    DeLone, David R.
    Pallanch, John F.
    Lindell, E. Paul
    McCollough, Cynthia H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (02) : W193 - W201
  • [36] Intraoperative CT and cone-beam CT imaging for minimally invasive evacuation of spontaneous intracerebral hemorrhage
    Nils Hecht
    Marcus Czabanka
    Paul Kendlbacher
    Julia-Helene Raff
    Georg Bohner
    Peter Vajkoczy
    Acta Neurochirurgica, 2020, 162 : 3167 - 3177
  • [37] Image Quality Optimization and Soft Tissue Visualization in Cone-Beam CT Imaging
    Castonguay-Henri, Aude
    Matenine, Dmitri
    Schmittbuhl, Matthieu
    de Guise, Jacques A.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 1, 2019, 68 (01): : 283 - 288
  • [38] Intraoperative navigation in the maxillofacial area based on 3D imaging obtained by a cone-beam device
    Mischkowski, R. A.
    Zinser, M. J.
    Ritter, L.
    Neugebauer, J.
    Keeve, E.
    Zoeller, J. E.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2007, 36 (08) : 687 - 694
  • [39] Navigated percutaneous versus open pedicle screw implantation using intraoperative CT and robotic cone-beam CT imaging
    Tkatschenko, Dimitri
    Kendlbacher, Paul
    Czabanka, Marcus
    Bohner, Georg
    Vajkoczy, Peter
    Hecht, Nils
    EUROPEAN SPINE JOURNAL, 2020, 29 (04) : 803 - 812
  • [40] Task-driven image acquisition and reconstruction in cone-beam CT
    Gang, Grace J.
    Stayman, J. Webster
    Ehtiati, Tina
    Siewerdsen, Jeffrey H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (08): : 3129 - 3150