VISUALIZATION OF ANTERIOR SKULL BASE DEFECTS WITH INTRAOPERATIVE CONE-BEAM CT

被引:8
|
作者
Bachar, Gideon [1 ]
Barker, Emma [1 ]
Chan, Harley [2 ]
Daly, Michael J. [2 ]
Nithiananthan, Sajendra [2 ,3 ]
Vescan, Al [4 ]
Irish, Jonathan C. [1 ]
Siewerdsen, Jeffrey H. [2 ,3 ,5 ]
机构
[1] Princess Margaret Hosp, Dept Surg Oncol, Dept Otolaryngol Head & Neck Surg, Toronto, ON M4X 1K9, Canada
[2] Univ Toronto, Inst Med Sci, Univ Hlth Network, Ontario Canc Inst,Princess Margaret Hosp, Toronto, ON M5S 1A1, Canada
[3] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
[4] Mt Sinai Hosp, Dept Otolaryngol Head & Neck Surg, Toronto, ON M5G 1X5, Canada
[5] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD USA
来源
HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK | 2010年 / 32卷 / 04期
基金
美国国家卫生研究院;
关键词
cone-beam CT; sinus; skull base; surgery; intraoperative; imaging; cerebrospinal fluid (CSF); CEREBROSPINAL-FLUID RHINORRHEA; HIGH-RESOLUTION CT; COMPUTED-TOMOGRAPHY; MR CISTERNOGRAPHY; DIAGNOSIS; SURGERY; FISTULA; GUIDANCE; PANEL; ARM;
D O I
10.1002/hed.21219
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Background. The role of cone-beam CT (CBCT) in demonstrating anterior skull base defects (ASBDs), differing in size and location, was investigated. The study was designed to describe the potential advantage of CBCT in the setting of an intraoperative cerebrospinal fluid (CSF) leak. Methods. In all, 120 ASBD were evaluated in 5 cadaver heads. Orthogonal and oblique slices were reconstructed. Observer studies assessed the visibility of ASBD in each location as a function of defect size. Results. For 1-, 2-, and 4-mm defects, the percentage that were undetectable ranged from 20% to 33%, 0% to 14%, and 0% to 5%, respectively. Confident breach detection increased with defect size and was most challenging in the lateral lamella and cribriform. CBCT permitted confident detection of ASBD as small as about 2 mm in the fovea ethmoidalis and planum. Oblique views were found to be superior to orthogonal planes. Conclusions. The ability to identify ASBD depended on the size and location of defect. Oblique viewing planes were optimal for ASBD visualization. (C) 2009 Wiley Periodicals, Inc. Head Neck 32: 504-512, 2010
引用
收藏
页码:504 / 512
页数:9
相关论文
共 50 条
  • [21] Recent Advances in Cone-beam CT in Oral Medicine
    Maret, Delphine
    Vergnes, Jean-Noel
    Peters, Ove A.
    Peters, Christine
    Nasr, Karim
    Monsarrat, Paul
    CURRENT MEDICAL IMAGING, 2020, 16 (05) : 553 - 564
  • [22] Intraoperative imaging and navigation with mobile cone-beam CT in maxillofacial surgery
    Quentin Goguet
    Sang Hwy Lee
    Julie Longis
    Pierre Corre
    Hélios Bertin
    Oral and Maxillofacial Surgery, 2019, 23 : 487 - 491
  • [23] Anterior Skull Base Defects - Algorithm for Reconstruction
    Hoffmann, T. K.
    Scheithauer, M.
    Koenig, R.
    Schuler, P. J.
    LARYNGO-RHINO-OTOLOGIE, 2014, 93 (11) : 768 - 777
  • [24] Cone-Beam CT Assessment of the Position of the Medial Lingual Foramen for Dental Implant Placement in the Anterior Symphysis
    Sanchez-Perez, Arturo
    Boix-Garcia, Paula
    Lopez-Jornet, Pia
    IMPLANT DENTISTRY, 2018, 27 (01) : 43 - 48
  • [25] Real-time tracking and virtual endoscopy in cone-beam CT-guided surgery of the sinuses and skull base in a cadaver model
    Prisman, Eitan
    Daly, Michael J.
    Chan, Harley
    Siewerdsen, Jeffrey H.
    Vescan, Allan
    Irish, Jonathan C.
    INTERNATIONAL FORUM OF ALLERGY & RHINOLOGY, 2011, 1 (01) : 70 - 77
  • [26] Demons deformable registration of CT and cone-beam CT using an iterative intensity matching approach
    Nithiananthan, Sajendra
    Schafer, Sebastian
    Uneri, Ali
    Mirota, Daniel J.
    Stayman, J. Webster
    Zbijewski, Wojciech
    Brock, Kristy K.
    Daly, Michael J.
    Chan, Harley
    Irish, Jonathan C.
    Siewerdsen, Jeffrey H.
    MEDICAL PHYSICS, 2011, 38 (04) : 1785 - 1798
  • [27] Comparative evaluation of cone-beam CT equipment with micro-CT in the visualization of root canal system
    Szabo, Bence Tamas
    Pataky, Levente
    Mikusi, Regina
    Fejerdy, Pal
    Dobo-Nagy, Csaba
    ANNALI DELL ISTITUTO SUPERIORE DI SANITA, 2012, 48 (01): : 49 - 52
  • [28] Intraoperative Endodontic Applications of Cone-Beam Computed Tomography
    Ball, Randy L.
    Barbizam, Joao V.
    Cohenca, Nestor
    JOURNAL OF ENDODONTICS, 2013, 39 (04) : 548 - 557
  • [29] Cone-beam CT to assess bony fusion following anterior cervical interbody fusion
    Vandevenne, Jan Erik
    Peuskens, Dieter
    Wijnen, Leen
    Wuyts, Jan
    EUROPEAN SPINE JOURNAL, 2016, 25 : S134 - S139
  • [30] Antiscatter grids in mobile C-arm cone-beam CT: Effect on image quality and dose
    Schafer, S.
    Stayman, J. W.
    Zbijewski, W.
    Schmidgunst, C.
    Kleinszig, G.
    Siewerdsen, J. H.
    MEDICAL PHYSICS, 2012, 39 (01) : 153 - 159