Treatment of small coronary arteries with a paclitaxel-coated balloon catheter

被引:197
作者
Unverdorben, Martin [2 ]
Kleber, Franz X. [3 ]
Heuer, Hubertus [4 ]
Figulla, Hans-Reiner [5 ]
Vallbracht, Christian [6 ]
Leschke, Matthias [7 ]
Cremers, Bodo [1 ]
Hardt, Stefan [8 ]
Buerke, Michael [9 ]
Ackermann, Hanns [10 ]
Boxberger, Michael [11 ]
Degenhardt, Ralf [2 ]
Scheller, Bruno [1 ]
机构
[1] Univ Klinikum Saarlandes, Innere Med Klin 3, Homburg, Germany
[2] Herz & Kreislaufzentrum, Inst Klin Forsch, Rotenburg, Germany
[3] Charite, Innere Med Klin, Unfallkrankenhaus Berlin, D-13353 Berlin, Germany
[4] St Johannes Hosp, Med Klin, Dortmund, Germany
[5] Univ Klinikum Jena, Innere Med Klin, Jena, Germany
[6] Herz & Kreislaufzentrum, Kardiol Klin, Rotenburg, Germany
[7] Klinikum Esslingen, Klin Kardiol Pneumol & Angiol, Esslingen, Germany
[8] Univ Klinikum Heidelberg, Heidelberg, Germany
[9] Univ Klin & Poliklin Innere Med 2, Halle, Germany
[10] Goethe Univ Frankfurt, Zentrum Med Informat, Abt Biomath, Frankfurt, Germany
[11] B Braun Melsungen AG, Vasc Syst, Berlin, Germany
关键词
Drug-coated balloon; Coronary small vessel; Paclitaxel; Restenosis; SIROLIMUS-ELUTING STENTS; RANDOMIZED-TRIAL; SMALL VESSELS; RESTENOSIS; ANGIOPLASTY; PREVENTION; LESIONS; THROMBOSIS; DELIVERY; METAANALYSIS;
D O I
10.1007/s00392-009-0101-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Treatment of lesions in small coronary arteries by percutaneous transluminal coronary intervention is limited by a high recurrence rate. We assessed the use of a paclitaxel-coated balloon in this indication. One-hundred eighteen patients with stenoses in small coronary vessels were treated by a paclitaxel-coated balloon (3 mu g/mm(2)). The main inclusion criteria encompassed diameter stenosis of a parts per thousand yen70% and a parts per thousand currency sign22 mm in length with a vessel diameter of 2.25-2.8 mm. Follow-up angiography was performed at scheduled 6-month post-intervention or whenever driven by clinical or electrocardiographic signs of ischemia. The primary endpoint was angiographic in-segment late lumen loss. Eighty-two of 118 patients (70%) with a vessel diameter of 2.35 +/- A 0.19 mm were treated with the drug-coated balloon only, while 32 patients required additional stent deployment. The mean in-segment late lumen loss was 0.28 +/- A 0.53 mm. In patients treated with the drug-coated balloon only, the in-segment late lumen loss was 0.16 +/- A 0.38 mm. At 12 months, the rate of major adverse cardiac events was 15% which was primarily due to the need for target lesion revascularization in 14 patients (12%). In those with additional bare metal stent implantation geographical mismatch between coated-balloon dilatation and stent implantation was significantly associated with the occurrence of restenosis. Treatment of coronary stenosis in small coronary vessels with the paclitaxel-coated balloon was well tolerated. It may offer an alternative to the implantation of a drug-eluting stent (ClinicalTrials.gov Identifier: NCT00404144).
引用
收藏
页码:165 / 174
页数:10
相关论文
共 34 条
[31]   Endoluminal beta-radiation therapy for the prevention of coronary restenosis after balloon angioplasty. [J].
Verin, V ;
Popowski, Y ;
de Bruyne, B ;
Baumgart, D ;
Sauerwein, W ;
Lins, M ;
Kovacs, G ;
Thomas, M ;
Calman, F ;
Disco, C ;
Serruys, PW ;
Wijns, W .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 344 (04) :243-249
[32]   Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent should we be cautious? [J].
Virmani, R ;
Guagliumi, G ;
Farb, A ;
Musumeci, G ;
Grieco, N ;
Motta, T ;
Mihalcsik, L ;
Tespili, M ;
Valsecchi, O ;
Kolodgie, FD .
CIRCULATION, 2004, 109 (06) :701-705
[33]   Late thrombosis after radiation - Sitting on a time bomb [J].
Waksman, R .
CIRCULATION, 1999, 100 (08) :780-782
[34]   Inhibition of restenosis in femoropopliteal arteries - Paclitaxel-coated versus uncoated balloon: Femoral paclitaxel randomized pilot trial [J].
Werk, Michael ;
Langner, Soenke ;
Reinkensmeier, Bianka ;
Boettcher, Hans-Frank ;
Tepe, Gunnar ;
Dietz, Ulrich ;
Hosten, Norbert ;
Hamm, Bernd ;
Speck, Ulrich ;
Ricke, Jens .
CIRCULATION, 2008, 118 (13) :1358-1365