Clinical and Radiographic Comparison between Platform-Shifted and Nonplatform-Shifted Implant: A One-Year Prospective Study

被引:13
作者
Glibert, Maarten [1 ]
Vervaeke, Stijn [1 ]
De Bruyn, Hugo [1 ,2 ]
Oestman, Paer-Olov [1 ]
机构
[1] Univ Ghent, Fac Med & Hlth Sci, Sch Dent, Dept Periodontol & Oral Implantol, B-9000 Ghent, Belgium
[2] Malmo Univ, Sch Dent, Dept Prosthodont, Malmo, Sweden
关键词
bone volume; dental implants; immediate loading; implant design; osseotite; 2; platform shifting; IMMEDIATELY LOADED IMPLANTS; DENTAL IMPLANTS; CRESTAL BONE; PERI-IMPLANTITIS; EDENTULOUS JAWS; MARGINAL BONE; SURFACE; SURVIVAL; RESTORATIONS; STABILITY;
D O I
10.1111/cid.12269
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundDevelopments in implant hardware and biologic understanding improved treatment predictability in terms of implant survival. Current research focuses on accelerated loading protocols and crestal bone preservation. PurposeThis prospective, monocenter study analyzed the clinical and radiographic outcome of a novel parallel-walled implant, with and without platform shift. Materials and MethodsForty-eight consecutively treated patients (30 women, 18 men) with crowns/bridges supported by 115 implants were included. Eighty-three percent of implants were nonocclusal, immediately loaded, and 17% were subjected to one-stage surgery and delayed loading after 10 weeks; 39.1% were of diameter 5.0mm, enabling platform shifting with a 4.0mm-wide prosthetic component; 60.9% were of diameter 4.0mm with a 4.0mm component. Radiographic crestal bone levels were assessed at baseline and 1 year. A multivariate statistical analysis was performed to determine factors affecting crestal bone loss after 1 year. ResultsAll implants survived and mean marginal bone loss was 0.73mm (SD: 0.13; range: -0.60 to 5.0mm). There was a statistically significant difference between platform-shifted (0.63mm; SD: 0.18) and nonplatform-shifted (1.02mm; SD: 0.14) implants. Implants in abundant bone volume lost significant less crestal bone (0.45mm; SD: 0.14) compared with implants in small volume (1.20mm; SD: 0.21). Implant diameter, loading time, anatomical position, smoking, and bone quality did not affect crestal bone loss. ConclusionAfter 1 year of loading, both implant-prosthetic features yield a high survival and limited crestal bone loss. Crestal bone loss is minimized using platform-shifted implants placed in sufficiently voluminous bone. To limit the crestal bone loss, an adopted implant diameter with platform shifting should be considered.
引用
收藏
页码:129 / 137
页数:9
相关论文
共 42 条
  • [21] Efficacy of Er: YAG Laser in the Decontamination of Peri-implant Disease: A One-Year Prospective Closed Cohort Study
    Norton, Michael R.
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2017, 37 (06) : 781 - 788
  • [22] Clinical Prospective Study of a Modified Technique to Extend the Keratinized Gingiva Around Implants in Combination with Ridge Augmentation: One-Year Results
    Stimmelmayr, Michael
    Stangl, Martin
    Edelhoff, Daniel
    Beuer, Florian
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (05) : 1094 - 1101
  • [23] Clinical Prospective Study of a Modified Technique to Extend the Keratinized Gingiva Around Implants in Combination with Ridge Augmentation: One-Year Results
    Stimmelmayr, Michael
    Stangl, Martin
    Edelhoff, Daniel
    Beuer, Florian
    IMPLANTOLOGIE, 2012, 20 (03): : 311 - 321
  • [24] Comparison of clinical and radiographic peri-implant parameters among obese and non-obese patients: A 5-year study
    Alkhudhairy, Fahad
    Vohra, Fahim
    Al-Kheraif, Abdulaziz A.
    Akram, Zohaib
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (05) : 756 - 762
  • [25] Immediate implant placement for a single anterior maxillary tooth with a facial bone wall defect: A prospective clinical study with a one-year follow-up period
    Liu, Renzhang
    Yang, Zhen
    Tan, Jianguo
    Chen, Li
    Liu, Hanqing
    Yang, Jianjun
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (06) : 1164 - 1174
  • [26] Effect of Implant Position on Clinical and Radiographic Outcomes of Locator-Retained Mandibular Overdentures: A 1-Year Prospective Study
    ELsyad, Moustafa Abdou
    Maryod, Waleed Hamed
    Mostafa, Aisha Zakaria
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (02): : E699 - E704
  • [27] Radiographic and Clinical Evaluation of Implant Prosthetic Treatment with One Piece versus Two Piece Dental Implants: A Comparative Prospective Study
    Liji, Balakrishnan
    Padmasree, Sankaranarayanan
    Ajitha, Suresh K.
    Ramya, Duraisamy
    Ranukumari, Attavar
    Shakila, Rajaraman
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2023, 15 : S481 - S485
  • [28] One-Year Prospective Study of 7-mm-Long Implants in the Mandible: Installation Technique and Crown/Implant Ratio of 1.5 or Less
    Kim, Young-Kyun
    Yun, Pil-Young
    Yi, Yang-Jin
    Bae, Ji-Hyun
    Kim, Sung-Beom
    Ahn, Gyo-Jin
    Journal of Oral Implantology, 2015, 41 (02) : E30 - E35
  • [29] Comparison of functional outcomes and patient-reported satisfaction between titanium and absorbable plates and screws for fixation of mandibular fractures: A one-year prospective study
    Leno, Maria Belen
    Liu, Stanley Yung
    Chen, Chien-Tzung
    Liao, Han-Tsung
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2017, 45 (05) : 704 - 709
  • [30] Comparison of implant-retained mandibular overdentures and conventional complete dentures: A 10-year prospective study of clinical aspects and patient satisfaction
    Meijer, HJA
    Raghoebar, GM
    Van't Hof, MA
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2003, 18 (06) : 879 - 885