Left Ventricular Assist Device Flow Pattern Analysis Using a Novel Model Incorporating Left Ventricular Pulsatility

被引:14
作者
Grinstein, Jonathan [1 ]
Torii, Ryo [2 ]
Bourantas, Christos V. [3 ]
Garcia-Garcia, Hector M. [4 ]
机构
[1] Univ Chicago, Dept Med, Cardiol Sect, Chicago, IL 60637 USA
[2] UCL, Dept Mech Engn, London, England
[3] Barts Heart Ctr, Dept Cardiol, London, England
[4] MedStar Cardiovasc Res Network, Washington, DC USA
关键词
computational fluid dynamics; LVAD flow; Programable flow algorithms; shear stress; shear rate; COMPUTATIONAL FLUID-DYNAMICS; HEARTMATE II; BLOOD-FLOW; SUPPORT; THROMBOSIS; STRESS; SYSTEM;
D O I
10.1097/MAT.0000000000001341
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Our current understanding of flow through the circuit of left ventricular assist device (LVAD), left ventricle and ascending aorta remains incompletely understood. Computational fluid dynamics, which allow for analysis of flow in the cardiovascular system, have been used for this purpose, although current simulation models have failed to fully incorporate the interplay between the pulsatile left ventricle and continuous-flow generated by the LVAD. Flow-through the LVAD is dependent on the interaction between device and patient-specific factors with suboptimal flow patterns evoking increased risk of LVAD-related complications. Computational fluid dynamics can be used to analyze how different pump and patient factors affect flow patterns in the left ventricle and the aorta. Computational fluid dynamics simulations were carried out on a patient with a HeartMate II. Simulations were also conducted for theoretical scenarios substituting HeartWare HVAD, HeartMate 3 (HM3) in continuous mode and HM3 with Artificial Pulse. An anatomical model of the patient was reconstructed from computed tomography (CT) images, and the LVAD outflow was used as the inflow boundary condition. The LVAD outflow was calculated separately using a lumped-parameter-model of the systemic circulation, which was calibrated to the patient based on the patient-specific ventricular volume change reconstructed from 4 dimensional computed tomography and pulmonary capillary wedge pressure tracings. The LVADs were implemented in the lumped-parameter-model via published pressure head versus flow (H-Q) curves. To quantify the flushing effect, virtual contrast agent was released in the ascending aorta and its flushing over the cycles was quantified. Shear stress acting on the aortic endothelium and shear rate in the bloodstream were also quantified as indicators of normal/abnormal blood flow, especially the latter being a biomarker of platelet activation and hemolysis. LVAD speeds for the HVAD and HM3 were selected to match flow rates for the patient's HMII (9,000 RPM for HMII, 5,500 RPM for HM3, and 2,200 RPM for HVAD), the cardiac outputs were 5.81 L/min, 5.83 L/min, and 5.92 L/min, respectively. The velocity of blood flow in the outflow cannula was higher in the HVAD than in the two HeartMate pumps with a cycle average (range) of 0.92 m/s (0.78-1.19 m/s), 0.91 m/s (0.86-1.00 m/s), and 1.74 m/s (1.40-2.24 m/s) for HMII, HM3, and HVAD, respectively. Artificial pulse increased the peak flow rate to 9.84 L/min for the HM3 but the overall cardiac output was 5.96 L/min, which was similar to the continuous mode. Artificial pulse markedly decreased blood stagnation in the ascending aorta; after six cardiac cycles, 48% of the blood was flushed out from the ascending aorta under the continuous operation mode while 60% was flushed under artificial pulse. Shear stress and shear rate in the aortic arch were higher with the HVAD compared to the HMII and HM3, respectively (shear stress: 1.76 vs. 1.33 vs. 1.33 Pa, shear rate: 136 vs. 91.5 vs. 89.4 s(-1)). Pump-specific factors such as LVAD type and programmed flow algorithms lead to unique flow patterns which influence blood stagnation, shear stress, and platelet activation. The pump-patient interaction can be studied using a novel computational fluid dynamics model to better understand and potentially mitigate the risk of downstream LVAD complications.
引用
收藏
页码:724 / 732
页数:9
相关论文
共 50 条
  • [21] Microparticles and left ventricular assist device complications: A causal association?
    Shah, Keyur B.
    Kontos, Michael. C.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (05) : 468 - 469
  • [22] Pulmonary Artery Pulsatility Index Is Associated With Right Ventricular Failure After Left Ventricular Assist Device Surgery
    Morine, Kevin J.
    Kiernan, Michael S.
    Duc Thinh Pham
    Paruchuri, Vikram
    Denofrio, David
    Kapur, Navin K.
    JOURNAL OF CARDIAC FAILURE, 2016, 22 (02) : 110 - 116
  • [23] Pulmonary artery pulsatility index predicts right ventricular failure after left ventricular assist device implantation
    Kang, Guson
    Ha, Richard
    Banerjee, Dipanjan
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (01) : 67 - 73
  • [24] Rotational speed modulation used with continuous-flow left ventricular assist device provides good pulsatility
    Naito, Noritsugu
    Nishimura, Takashi
    Iizuka, Kei
    Takewa, Yoshiaki
    Umeki, Akihide
    Ando, Masahiko
    Ono, Minoru
    Tatsumi, Eisuke
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2018, 26 (01) : 119 - 123
  • [25] Evaluation of a Novel Left Ventricular Assist Device for Resuscitation in an Animal Model of Ventricular Fibrillation Cardiac Arrest
    Wang, Zongtao
    Yu, Huiming
    Yan, Shiping
    Yan, Hong
    Chen, Danhong
    Dai, Yining
    Xu, Qichun
    Zeng, Zhihuan
    Zhang, Wei
    Jin, Lijun
    IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2022, 10
  • [26] The impact of right ventricular hemodynamics on the performance of a left ventricular assist device in a numerical simulation model
    Thut, Titus L. Z.
    Petrou, Anastasios
    Meboldt, Mirko
    Daners, Marianne Schmid
    Wilhelm, Markus J.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2023, 68 (05): : 503 - 510
  • [27] Further Peripheral Vascular Dysfunction in Heart Failure Patients With a Continuous-Flow Left Ventricular Assist Device The Role of Pulsatility
    Witman, Melissa A. H.
    Garten, Ryan S.
    Gifford, Jayson R.
    Groot, H. Jonathan
    Trinity, Joel D.
    Stehlik, Josef
    Nativi, Jose N.
    Selzman, Craig H.
    Drakos, Stavros G.
    Richardson, Russell S.
    JACC-HEART FAILURE, 2015, 3 (09) : 703 - 711
  • [28] Ventricular Arrhythmias in Patients With Left Ventricular Assist Device (LVAD)
    Ahmed, Azza
    Amin, Mustapha
    Boilson, Barry A.
    Killu, Ammar M.
    Madhavan, Malini
    CURRENT TREATMENT OPTIONS IN CARDIOVASCULAR MEDICINE, 2019, 21 (11)
  • [29] Computational fluid dynamics of left ventricular assist device under unsteady flow
    BUMRUNGPETCH J
    TAN AC
    排灌机械工程学报, 2016, 34 (02) : 93 - 98
  • [30] Early Assistance With Left Ventricular Assist Device Limits Left Ventricular Remodeling After Acute Myocardial Infarction in a Swine Model
    Sun, Xiaotian
    Li, Jun
    Zhao, Weipeng
    Lu, Shuyang
    Guo, Changfa
    Lai, Hao
    Wang, Chunsheng
    ARTIFICIAL ORGANS, 2016, 40 (03) : 243 - 251