Intra-oral storage phosphor and conventional radiography in the assessment of alveolar bone structures

被引:18
作者
Kaeppler, G [1 ]
Vogel, A [1 ]
Axmann-Krcmar, D [1 ]
机构
[1] Univ Tubingen, Sch Dent Med, Dept Oral Radiol, D-72074 Tubingen, Germany
关键词
radiography; dental; digital radiography; diagnostic errors; observer variation;
D O I
10.1038/sj.dmfr.4600556
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To compare storage phosphor (SP) with conventional film radiography for accuracy of linear measurements of the marginal alveolar bone and visibility of anatomical structures. Methods: Linear measurements were made in paired SP and conventional images of dried human mandibles with a metal pin fixed 10 mm below the alveolar crest. One observer measured the distance from the alveolar crest to the reference point on the radiographs, The difference between the measured and the true distance was calculated, Two observers rated the visibility of bony structures (periodontal ligament space, periapical bone tissue, alveolar crest) in 51 paired digital and conventional images of 21 patients on a 3-point scale. Overall agreement and Kappa index were calculated. Results: Accuracy of linear measurements was higher in digital radiography (mean difference 0.17 mm) than in conventional radiography (mean difference 0.59 mm). Overall, the two observers rated visibility higher in conventional radiographs. The Kappa indices for the periodontal ligament space and periapical bone indicated fair to almost perfect agreement (kappa = 0.38 and 0.5; kappa = 0.39 and 0.54) while for the alveolar crest there was only poor or moderate agreement (kappa = 0,2 and 0,5), Conclusions: The small differences in Linear measurements indicate that the Digora(R) system is suitable for clinical assessment of periodontal and peri-implant bone loss. The visibility of dental structures depends as much on the individual features assessed, as the radiographic system.
引用
收藏
页码:362 / 367
页数:6
相关论文
共 37 条
[1]   Detectability of artificial periapical lesions using direct digital and conventional radiography [J].
Barbat, J ;
Messer, HH .
JOURNAL OF ENDODONTICS, 1998, 24 (12) :837-842
[2]  
Borg E, 1996, ENDOD DENT TRAUMATOL, V12, P20
[3]   Marginal bone level buccal to mandibular molars in digital radiographs from charge-coupled device and storage phosphor systems - An in vitro study [J].
Borg, E ;
Grondahl, K ;
Grondahl, HG .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1997, 24 (05) :306-312
[4]   A comparison of the diagnostic utility of two image receptors for panoramic radiography [J].
Carmichael, FA ;
Hirschmann, PN ;
Scaife, B ;
Sheard, L ;
Mackenzie, A .
DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (01) :57-60
[5]   Endodontic working length assessment - Comparison of storage phosphor digital imaging and radiographic film [J].
Cederberg, RA ;
Tidwell, E ;
Frederiksen, NL ;
Benson, BW .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1998, 85 (03) :325-328
[6]   Comparison of linear measurements made from storage phosphor and dental radiographs [J].
Conover, GL ;
Hildebolt, CF ;
YokoyamaCrothers, N .
DENTOMAXILLOFACIAL RADIOLOGY, 1996, 25 (05) :268-273
[7]  
Farman TT, 1996, INT CONGR SER, V1124, P957
[8]   Observers' use of image enhancement in assessing caries in radiographs taken by four intra-oral digital systems [J].
Gotfredsen, E ;
Wenzel, A ;
Grondahl, HG .
DENTOMAXILLOFACIAL RADIOLOGY, 1996, 25 (01) :34-38
[9]   EXAMINER AGREEMENT IN ESTIMATING CHANGES IN PERIODONTAL BONE FROM CONVENTIONAL AND SUBTRACTION RADIOGRAPHS [J].
GRONDAHL, K ;
GRONDAHL, HG ;
WENNSTROM, J ;
HEIJL, L .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1987, 14 (02) :74-79
[10]   Intraoral radiographic storage phosphor image mean pixel values and signal-to-noise ratio - Effects of calibration [J].
Hayakawa, Y ;
Farman, AG ;
Kelly, MS ;
Kuroyanagi, K .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1998, 86 (05) :601-605