Broadband Impedance Spectroscopy For Locating and Detecting Various Type Of Degraded Portion Along with Polymeric Cable

被引:1
|
作者
Siswoyo, Agung [1 ,2 ]
Zhang, Guan-Jun [3 ]
Suwarno [1 ]
机构
[1] Inst Teknol Bandung, Sch Elect & Informat Engn, Bandung, Indonesia
[2] PT PLN Persero, Jakarta, Indonesia
[3] Xi An Jiao Tong Univ, Sch Elect Engn, Xian 710049, Shaanxi, Peoples R China
关键词
Diagnosis of the cable system; Nondestructive electrical test; Broadband Impedance Spectroscopy; degraded local portion; DIAGNOSIS;
D O I
10.1109/CPEEE51686.2021.9383355
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The problem that often occurs in the field is the occurrence of soft defects that occur when installing cables due to various factors such as being pinched, punctured, or peeled. Over last year, many methods are based on non-destructive tests such as Line Resonance Analysis (LIRA), Broadband Impedance Spectroscopy (BIS). Time Domain Reflectometry, Joint Time-Frequency Domain Reflectometry is carried out. Although some of these test methods have been able to detect local degradation but to interpret the type of defect is still infancy. This work uses the BIS method with RG 58 CU cable of 33.5 meters total length. The degraded portion is done by using several types, The first is to use mechanical damage by bending beyond the cable's tolerance limit damage, and the second is by connecting the resistance (100 Ohm) or capacitance (10nF) value using the T joint connector. The results are comparing by simulation with ANSYS Electronics Desktop. The results are the type of defect caused by the mechanical press, and the peeled parts have different characteristics. Besides, the IT transform method and IFFT method both of them can detect precisely the degraded portion at 18.5 meters long of 33.5 meters total length of the cable under test.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 13 条
  • [1] A method for locating and diagnosing cable abrasion based on broadband impedance spectroscopy
    Zhang, Haotian
    Mu, Haibao
    Lu, Xu
    Tian, Jie
    Zou, Xingyu
    Zhang, Guanjun
    ENERGY REPORTS, 2022, 8 : 1492 - 1499
  • [2] Comparison of Broadband Impedance Spectroscopy and Time Domain Reflectometry for Locating Cable Degradation
    Hirai, Naoshi
    Yamada, Takayuki
    Ohki, Yoshimichi
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 229 - 232
  • [3] Improvement in Sensitivity of Broadband Impedance Spectroscopy for Locating Degradation in Cable Insulation by Ascending the Measurement Frequency
    Yamada, Takayuki
    Hirai, Naoshi
    Ohki, Yoshimichi
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 677 - 680
  • [4] Diagnosis of Cable Aging by Broadband Impedance Spectroscopy
    Ohki, Yoshimichi
    Yamada, Takayuki
    Hirai, Naoshi
    2011 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS 1 AND 2, 2011, : 24 - 27
  • [5] Improved Locating Method for Local Defects in XLPE Cable Based on Broadband Impedance Spectrum
    Wei, Liqiang
    Pang, Xianhai
    Su, Jingang
    Han, Tao
    Yao, Yufei
    ENERGIES, 2022, 15 (21)
  • [6] Local Degradation Diagnosis for Cable Insulation based on Broadband Impedance Spectroscopy
    Zhou, Zhiqiang
    Zhang, Dandan
    He, Junjia
    Li, Menghu
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (04) : 2097 - 2107
  • [7] Locating Method for Electrical Tree Degradation in XLPE Cable Insulation Based on Broadband Impedance Spectrum
    Han, Tao
    Yao, Yufei
    Li, Qiang
    Huang, Youcong
    Zheng, Zhongnan
    Gao, Yu
    POLYMERS, 2022, 14 (18)
  • [8] Underground XLPE coaxial cable length calculation and fault detection based on broadband impedance spectroscopy
    Liu, Chunqi
    Chen, Dongsheng
    Hou, Yimin
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2025, 36 (01)
  • [9] Sensitivity Improvement in Cable Faults Location by Using Broadband Impedance Spectroscopy With Dolph-Chebyshev Window
    Mu, Hai-Bao
    Zhang, Hao-Tian
    Zou, Xing-Yu
    Zhang, Da-Ning
    Lu, Xu
    Zhang, Guan-Jun
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (05) : 3846 - 3854
  • [10] Broadband dielectric spectroscopy as an experimental alternative to calorimetric determination of the solubility of drugs into polymer matrix: Case of flutamide and various polymeric matrixes
    Chmiel, K.
    Knapik-Kowalczuk, J.
    Jachowicz, R.
    Paluch, M.
    EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2019, 136 : 231 - 239