Adaptation of the strain measurement in textile reinforced cementitious matrix composites by distributed optical fibre and 2D digital image correlation

被引:21
作者
Saidi, M. [1 ]
Gabor, A. [1 ]
机构
[1] Claude Bernard Univ Lyon 1, Lab Composite Mat Construct LMC2, 82 Bd Niels Bohr, F-69622 Lyon, France
关键词
digital image correlation (DIC); optical fibre; out-of-plane parasitic displacements; sensor calibration; strain sensors; textile reinforced concrete (TRC); CONCRETE; BEHAVIOR; SENSORS; MORTAR; INTERPOLATION; CALIBRATION; ERRORS; TRC;
D O I
10.1111/str.12335
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The study presented in this paper aims to adapt and calibrate two strain measurement techniques used for textile reinforced cementitious matrix composites (TRCMCs): distributed optical fibres and 2D digital image correlation (DIC). These composites exhibit tensile behaviour characterised by a succession of transverse cracks along specimens. During the tensile test, out-of-plane parasitic displacements may occur due to the geometry of specimens and possible imperfections of the test method. These phenomena interfere with the measurement of the strain sensors, leading to loss of results and parasitic strain. In order to eliminate them and to finely analyse the complex behaviour of TRCMCs, a test methodology and experimental approach are proposed for optical fibres, and a practical and simple solution is proposed to quantify the parasitic strains of the 2D DIC. For optical fibres, Rayleigh backscatter is used, allowing a millimetric spatial resolution and a high recording frequency. For the DIC, required equipment is used, and the results are processed through existing commercial software.
引用
收藏
页数:18
相关论文
共 40 条
[1]   Monitoring of the concrete curing process using plastic optical fibers [J].
Andre, P. S. ;
Varum, Humberto ;
Antunes, Paulo ;
Ferreira, Licinio ;
Sousa, M. G. .
MEASUREMENT, 2012, 45 (03) :556-560
[2]  
[Anonymous], 2013, APPROCHE METHODOLOGI
[3]  
[Anonymous], COMPORTEMENTS CAPTEU
[4]   Optical fiber sensors for static and dynamic health monitoring of civil engineering infrastructures: Abode wall case study [J].
Antunes, Paulo ;
Lima, Hugo ;
Varum, Humberto ;
Andre, Paulo .
MEASUREMENT, 2012, 45 (07) :1695-1705
[5]   Experimental Analysis of the Errors due to Polynomial Interpolation in Digital Image Correlation [J].
Baldi, A. ;
Bertolino, F. .
STRAIN, 2015, 51 (03) :248-263
[6]   Experimental study on effective bond length of basalt textile reinforced mortar strengthening system: Contributions of digital image correlation [J].
Caggegi, Carmelo ;
Sciuto, Denise ;
Cuomo, Massimo .
MEASUREMENT, 2018, 129 :119-127
[7]   Tensile behaviour of a basalt TRM strengthening system: Influence of mortar and reinforcing textile ratios [J].
Caggegi, Carmelo ;
Lanoye, Emma ;
Djama, Khaled ;
Bassil, Antoine ;
Gabor, Aron .
COMPOSITES PART B-ENGINEERING, 2017, 130 :90-102
[8]   Contribution to direct tensile testing of textile reinforced concrete (TRC) composites [J].
Contamine, R. ;
Larbi, A. Si ;
Hamelin, P. .
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2011, 528 (29-30) :8589-8598
[9]   Measuring Strain Using Optical Fibres [J].
Culshaw, B. .
STRAIN, 2000, 36 (03) :105-113
[10]   On the feasibility of optical fibre sensors for strain monitoring in thermoplastic composites under fatigue loading conditions [J].
De Baere, I. ;
Luyckx, G. ;
Voet, E. ;
Van Paepegem, W. ;
Degrieck, J. .
OPTICS AND LASERS IN ENGINEERING, 2009, 47 (3-4) :403-411