Assessment of thermal comfort in high-occupancy spaces with relevance to air distribution schemes: A case study of mosques

被引:22
作者
Samiuddin, S. [1 ]
Budaiwi, Ismail M. [2 ]
机构
[1] King Fahd Univ Petr & Minerals, Mech Engn Dept, PYP, Dhahran, Saudi Arabia
[2] King Fahd Univ Petr & Minerals, Architectural Engn Dept, Dhahran, Saudi Arabia
关键词
High-occupancy building; thermal comfort; ceiling-based air distribution system; predicted mean vote; air diffusion performance index; computational fluid dynamics; COMPUTATIONAL FLUID-DYNAMICS; VENTILATION SYSTEM; SIMULATION; THEATER; ENERGYPLUS; QUALITY;
D O I
10.1177/0143624418764769
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In high-occupancy intermittently operated buildings such as mosques and auditoriums, maintaining an acceptable thermal environment may present a challenging task. Variations in the operation and the thermal loads can result in variable and non-uniform thermal comfort conditions when the HVAC system is not properly designed. Non-uniformity of the thermal environment is greatly influenced by the design and scheme of the air distribution system. Mosques, with their distinctive five intermittent short occupancies and the non-fixed posture of occupants, present a unique case for investigation. In this study, the effect of air distribution of various schemes of a ceiling-based system on the thermal comfort in mosques is investigated. Air diffusion performance index and Fanger's PMV method are used to assess thermal comfort. Three air distribution schemes at four diffuser terminal velocities were studied using the EnergyPlus and computational fluid dynamics techniques. Results indicate major variations in air diffusion performance index with each air distribution scheme type and diffuser terminal velocity. The uniformity of the PMV was entirely dependent on the air diffusion performance index value and exhibited large variations when the air diffusion performance index value was low. In most cases, the space was overcooled with an average PMV of -0.66 or below. Practical application: The effect of air distribution system design on human thermal comfort has been very complex to understand, as it involves different schemes and different diffuser discharge velocities. This study will help engineers and designers in designing better thermal environment for the occupants.
引用
收藏
页码:572 / 589
页数:18
相关论文
共 28 条
[1]  
Abdou Al-Homoud A.A., 2005, ENG SCI J, V16, P165
[2]   Thermal comfort in air-conditioned mosques in the dry desert climate [J].
Al-ajmi, Farraj F. .
BUILDING AND ENVIRONMENT, 2010, 45 (11) :2407-2413
[3]   Assessment of monitored energy use and thermal comfort conditions in mosques in hot-humid climates [J].
Al-Homoud, Mohammad S. ;
Abdou, Adel A. ;
Budaiwi, Ismail M. .
ENERGY AND BUILDINGS, 2009, 41 (06) :607-614
[4]  
[Anonymous], 2013, ASHRAE
[5]   Envelope thermal design for energy savings in mosques in hot-humid climate [J].
Budaiwi, I. M. .
JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2011, 4 (01) :49-61
[6]   An approach to investigate and remedy thermal-comfort problems in buildings [J].
Budaiwi, Ismail M. .
BUILDING AND ENVIRONMENT, 2007, 42 (05) :2124-2131
[7]   Envelope retrofit and air-conditioning operational strategies for reduced energy consumption in mosques in hot climates [J].
Budaiwi, Ismail M. ;
Abdou, Adel A. ;
Al-Homoud, Mohammad S. .
BUILDING SIMULATION, 2013, 6 (01) :33-50
[8]   Thermal comfort study of an air-conditioned lecture theatre in the tropics [J].
Cheong, KWD ;
Djunaedy, E ;
Chua, YL ;
Tham, KW ;
Sekhar, SC ;
Wong, NH ;
Ullah, MB .
BUILDING AND ENVIRONMENT, 2003, 38 (01) :63-73
[9]  
Crawley DB, 2004, J ARCHIT PLAN RES, V21, P292
[10]  
Crawley DB, 2000, ASHRAE J, V42, P49