A Planning Comparison of IMRT vs. Pencil Beam Scanning for Deep Inspiration Breath Hold Lung Cancers

被引:4
作者
Mah, Dennis [1 ]
Yorke, Ellen [2 ]
Zemanaj, Entela [1 ]
Han, Zhiqiang [1 ]
Liu, Haoyang [1 ]
George, Jobin [1 ]
Lambiase, Jason [1 ]
Czmielewski, Christian [2 ]
Lovelock, D. Michael [2 ]
Rimner, Andreas [3 ]
Shepherd, Annemarie F. [3 ]
机构
[1] ProCure Proton Therapy Ctr, Dept Med Phys, Somerset, NJ 08873 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10065 USA
[3] Mem Sloan Kettering Canc Ctr, Dept Radiat Oncol, New York, NY 10065 USA
关键词
Proton therapy; Lung cancer; Deep inspiration breath hold; Planning comparison; PROTON THERAPY; MOTION MANAGEMENT; RADIOTHERAPY; VOLUME; INTERPLAY; TUMORS; IMMOBILIZATION; IRRADIATION; STRATEGIES; REDUCE;
D O I
10.1016/j.meddos.2021.07.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Deep inspiration breath hold (DIBH) has dosimetric advantages for lung cancer patients treated with external beam therapy, but is difficult for many patients to perform. Proton therapy permits sparing of the downstream organs at risk (OAR). We compared conventionally fractionated proton (p) and photon(x) plans on both free breathing (FB) and DIBH planning CTs to determine the effect of DIBH with proton therapy. We evaluated 24 plans from 6 lung cancer patients treated with photon DIBH on a prospective protocol. All patients were re-planned using pencil beam scanning (PBS) proton therapy. New plans were generated for FB datasets with both modalities. All plans were renormalized to 60 Gy. We evaluated dosimetric parameters for heart, lung and esophagus. We also compared FBp to DIBHx parameters to quantify how FBp plans compare to DIBHx plans. Significant differences were found for lung metrics V20 and mean lung dose between FB and DIBH plans regardless of treatment modality. Furthermore, lung metrics for FBp were comparable or superior to DIBHx, suggesting that FB protons may be a viable alternative for those patients that cannot perform DIBH with IMRT. The heart dose metrics were significantly different for the 5 out of 6 patients where the PTV overlapped the heart as DIBH moved heart out of the high dose volume. Heart dose metrics were further reduced by proton therapy. DIBH offers similar relative advantages for lung sparing for PBS as it does for IMRT but the magnitude of the DIBH related gains in OAR sparing were smaller for PBS than IMRT. FBp plans offer similar or better lung and heart sparing compared to DIBHx plans. For IMRT patients who have difficulty performing DIBH, FB protons may offer an alternative. (C) 2021 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:26 / 31
页数:6
相关论文
共 38 条
[1]   An effective method to reduce the interplay effects between respiratory motion and a uniform scanning proton beam irradiation for liver tumors: A case study [J].
Akino, Yuichi ;
Wu, Huanmei ;
Oh, Ryoong-Jin ;
Das, Indra J. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (01) :220-228
[2]  
Andersson Karin M, 2020, Tech Innov Patient Support Radiat Oncol, V13, P6, DOI 10.1016/j.tipsro.2019.11.006
[3]  
[Anonymous], SEER CANC STAT
[4]   Meta-Analysis of Concomitant Versus Sequential Radiochemotherapy in Locally Advanced Non-Small-Cell Lung Cancer [J].
Auperin, Anne ;
Le Pechoux, Cecile ;
Rolland, Estelle ;
Curran, Walter J. ;
Furuse, Kiyoyuki ;
Fournel, Pierre ;
Belderbos, Jose ;
Clamon, Gerald ;
Ulutin, Hakki Cuneyt ;
Paulus, Rebecca ;
Yamanaka, Takeharu ;
Bozonnat, Marie-Cecile ;
Uitterhoeve, Apollonia ;
Wang, Xiaofei ;
Stewart, Lesley ;
Arriagada, Rodrigo ;
Burdett, Sarah ;
Pignon, Jean-Pierre .
JOURNAL OF CLINICAL ONCOLOGY, 2010, 28 (13) :2181-2190
[5]   Dosimetric evaluation of lung tumor immobilization using breath hold at deep inspiration [J].
Barnes, EIA ;
Murray, BR ;
Robinson, DM ;
Underwood, LJ ;
Hanson, J ;
Roa, WHY .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (04) :1091-1098
[6]   Proton versus photon deep inspiration breath hold technique in patients with hodgkin lymphoma and mediastinal radiation A PLANNING COMPARISON OF DEEP INSPIRATION BREATH HOLD INTENSITY MODULATION RADIOTHERAPY AND INTENSITY MODULATED PROTON THERAPY [J].
Baues, Christian ;
Marnitz, Simone ;
Engert, Andreas ;
Baus, Wolfgang ;
Jablonska, Karolina ;
Fogliata, Antonella ;
Vasquez-Torres, Andres ;
Scorsetti, Marta ;
Cozzi, Luca .
RADIATION ONCOLOGY, 2018, 13
[7]   Randomized Trials of Proton Therapy: Why They Are at Risk, Proposed Solutions, and Implications for Evaluating Advanced Technologies to Diagnose and Treat Cancer [J].
Bekelman, Justin E. ;
Denicoff, Andrea ;
Buchsbaum, Jeffrey .
JOURNAL OF CLINICAL ONCOLOGY, 2018, 36 (24) :2461-+
[8]   Motion management strategies and technical issues associated with stereotactic body radiotherapy of thoracic and upper abdominal tumors: A review from NRG oncology [J].
Brandner, Edward D. ;
Chetty, Indrin J. ;
Giaddui, Tawfik G. ;
Xiao, Ying ;
Huq, M. Saiful .
MEDICAL PHYSICS, 2017, 44 (06) :2595-2612
[9]   Consensus Guidelines for Implementing Pencil-Beam Scanning Proton Therapy for Thoracic Malignancies on Behalf of the PTCOG Thoracic and Lymphoma Subcommittee [J].
Chang, Joe Y. ;
Zhang, Xiaodong ;
Knopf, Antje ;
Li, Heng ;
Mori, Shinichiro ;
Dong, Lei ;
Lu, Hsiao-Ming ;
Liu, Wei ;
Badiyan, Shahed N. ;
Both, Stephen ;
Meijers, Arturs ;
Lin, Liyong ;
Flampouri, Stella ;
Li, Zuofeng ;
Umegaki, Kikuo ;
Simone, Charles B., II ;
Zhu, Xiaorong R. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (01) :41-50
[10]   Motion Management for Radical Radiotherapy in Non-small Cell Lung Cancer [J].
Cole, A. J. ;
Hanna, G. G. ;
Jain, S. ;
O'Sullivan, J. M. .
CLINICAL ONCOLOGY, 2014, 26 (02) :67-80