Coronary artery calcium: A multi-institutional, multimanufacturer international standard for quantification at cardiac CT

被引:250
作者
McCollough, Cynthia H.
Ulzheimer, Stefan
Halliburton, Sandra S.
Shanneik, Kaiss
White, Richard D.
Kalender, Willi A.
机构
[1] Mayo Clin, Dept Radiol, Coll Med, Rochester, MN 55905 USA
[2] Univ Erlangen Nurnberg, Inst Med Phys, Erlangen, Germany
[3] Cleveland Clin, Div Radiol, Cleveland, OH USA
关键词
D O I
10.1148/radiol.2432050808
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a consensus standard for quantification of coronary artery calcium (CAC). Materials and Methods: A standard for CAC quantification was developed by a multi-institutional, multimanufacturer international consortium of cardiac radiologists, medical physicists, and industry representatives. This report specifically describes the standardization of scan acquisition and reconstruction parameters, the use of patient size-specific tube current values to achieve a prescribed image noise, and the use of the calcium mass score to eliminate scanner- and patient size-based variations. An anthropomorphic phantom containing calibration inserts and additional phantom rings were used to simulate small, medium-size, and large patients. The three phantoms were scanned by using the recommended protocols for various computed tomography (CT) systems to determine the calibration factors that relate measured CT numbers to calcium hydroxyapatite density and to determine the tube current values that yield comparable noise values. Calculation of the calcium mass score was standardized, and the variance in Agatston, volume, and mass scores was compared among CT systems. Results: Use of the recommended scanning parameters resulted in similar noise for small, medium-size, and large phantoms with all multi-detector row CT scanners. Volume scores had greater interscanner variance than did Agatston and calcium mass scores. Use of a fixed calcium hydroxyapatite density threshold (100 mg/ cm(3)), as compared with use of a fixed CT number threshold (130 HU), reduced interscanner variability in Agatston and calcium mass scores. With use of a density segmentation threshold, the calcium mass score had the smallest variance as a function of patient size. Conclusion: Standardized quantification of CAC yielded comparable image noise, spatial resolution, and mass scores among different patient sizes and different CT systems and facilitated reduced radiation dose for small and medium-size patients. (c) RSNA, 2007.
引用
收藏
页码:527 / 538
页数:12
相关论文
共 32 条
[1]   QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY [J].
AGATSTON, AS ;
JANOWITZ, WR ;
HILDNER, FJ ;
ZUSMER, NR ;
VIAMONTE, M ;
DETRANO, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) :827-832
[2]   Prediction of coronary events with electron beam computed tomography [J].
Arad, Y ;
Spadaro, LA ;
Goodman, K ;
Newstein, D ;
Guerci, AD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (04) :1253-1260
[3]   Coronary artery disease: Improved reproducibility of calcium scoring with an electron-beam CT volumetric method [J].
Callister, TQ ;
Cooil, B ;
Raya, SP ;
Lippolis, NJ ;
Russo, DJ ;
Raggi, P .
RADIOLOGY, 1998, 208 (03) :807-814
[4]  
DAS M, 2004, EUROPEAN RADIOLOGY S, V14, P539
[5]   REPRODUCIBILITY OF THE MEASUREMENT OF CORONARY CALCIUM WITH ULTRAFAST COMPUTED-TOMOGRAPHY [J].
DEVRIES, S ;
WOLFKIEL, C ;
SHAH, V ;
CHOMKA, E ;
RICH, S .
AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (14) :973-975
[6]  
Fishman EK, 2004, MULTIDETECTOR CT PRI
[7]   Image reconstruction and performance evaluation for ECG-gated spiral scanning with a 16-slice CT system [J].
Flohr, T ;
Ohnesorge, B ;
Bruder, H ;
Stierstorfer, K ;
Simon, J ;
Suess, C ;
Schaller, S .
MEDICAL PHYSICS, 2003, 30 (10) :2650-2662
[8]  
FURUHASHI S, 2003, RAD SOC N AM SCI ASS, P631
[9]   Electron-beam CT: The effect of using a correction function on coronary artery calcium quantitation [J].
Greaser, LE ;
Yoon, HC ;
Mather, RT ;
McNitt-Gray, M ;
Goldin, JG .
ACADEMIC RADIOLOGY, 1999, 6 (01) :40-48
[10]   Potential clinical impact of variability in the measurement of coronary artery calcification with sequential MDCT [J].
Halliburton, SS ;
Stillman, AE ;
Lieber, M ;
Kasper, JM ;
Kuzmiak, SA ;
White, RD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (02) :643-648