A UPLC-MS/MS method for analysis of vancomycin in human cerebrospinal fluid and comparison with the chemiluminescence immunoassay

被引:4
|
作者
Mei, Shenghui [1 ,2 ]
Wang, Jiaqing [1 ]
Zhu, Leting [1 ]
Chen, Ruiling [1 ,2 ]
Li, Xingang [1 ,2 ]
Chen, Kai [3 ]
Chen, Guangqiang [3 ]
Zhou, Jianxin [3 ]
Wang, Qiang [3 ]
Zhao, Zhigang [1 ,2 ]
机构
[1] Capital Med Univ, Beijing Tiantan Hosp, Dept Pharm, 6 Tiantan Xili, Beijing 100050, Peoples R China
[2] Capital Med Univ, Dept Clin Pharmacol, Coll Pharmaceut Sci, Beijing, Peoples R China
[3] Capital Med Univ, Beijing Tiantan Hosp, Intens Care Unit, 6 Tiantan Xili, Beijing 100050, Peoples R China
关键词
cerebrospinal fluid; chemiluminescence immunoassay; method comparison; method development and validation; UPLC-MS/MS; vancomycin; PERFORMANCE LIQUID-CHROMATOGRAPHY; TANDEM MASS-SPECTROMETRY; LC-MS/MS; PLASMA; SERUM; QUANTIFICATION; EXTRACTION; AGREEMENT;
D O I
10.1002/bmc.3939
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Vancomycin (VCM) is clinically used in treating patients with postoperative intracranial infections. The cerebrospinal fluid (CSF) concentration of VCM varies greatly among patients. To guide the dosage regimens, monitoring of VCM in CSF is needed. However a method for analysis of VCM in human CSF is lacking. An ultraperformance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) was developed and validated for analysis of VCM in human CSF, and the agreement of UPLC-MS/MS and chemiluminescence immunoassay (CLIA) in the analysis of CSF VCM was evaluated. The ion transitions were m/z 725.5>144.1 for VCM and m/z 455.2>308.2 for methotrexate (internal standard). The agreement between UPLC-MS/MS and CLIA was evaluated by Bland-Altman plot in 179 samples. The calibration range of the UPLC-MS/MS method was 1-400mg/L. The inaccuracy and imprecision were -0.69-10.80% and <4.95%. The internal standard normalized recovery and matrix factor were 86.14-99.31 and 85.84-92.07%, respectively. The measurements of CLIA and UPLC-MS/MS were strongly correlated (r>0.98). The 95% limit of agreement of the ratio of CLIA to UPLC-MS/MS was 61.66-107.40%. Further studies are warranted to confirm the results.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] UPLC-MS/MS determination of voriconazole in human plasma and its application to a pharmacokinetic study
    Wang, Zhe
    Huang, Cheng-ke
    Sun, Wei
    Xiao, Cui
    Wang, Zeng-shou
    BIOMEDICAL CHROMATOGRAPHY, 2015, 29 (02) : 188 - 193
  • [32] Pharmacokinetic Study and UPLC-MS/MS Method Development of Ibrutinib in Mouse
    Liu, Wei-feng
    Zheng, Xiao-kang
    Chen, Ke-li
    Jiao, Yang
    Wang, Xin-shuai
    LATIN AMERICAN JOURNAL OF PHARMACY, 2016, 35 (08): : 1877 - 1882
  • [33] Validated UPLC-MS/MS Method for the Determination of Sunitinib in Rat Plasma
    Zhang, Yu
    Yuan, Rong-rong
    Zheng, Xiao-kang
    Hua, Chang-lin
    Wang, Ya-qiang
    LATIN AMERICAN JOURNAL OF PHARMACY, 2016, 35 (06): : 1304 - 1308
  • [34] Development and Validation of an UPLC-MS/MS Method for the Determination of Enalapril in Human Plasma
    Zhao, Jian-long
    Zheng, Xiao-kang
    Yin, Shi
    Wei, Jia-nan
    Yi, Xiao-wen
    Qiu, Xiang-jun
    LATIN AMERICAN JOURNAL OF PHARMACY, 2016, 35 (05): : 945 - 949
  • [35] Determination of vancomycin and meropenem in serum and synovial fluid of patients with prosthetic joint infections using UPLC-MS/MS
    He, Jiawei
    Wang, Jing
    Cao, Li
    Zhang, Xiaogang
    Li, Guoqing
    Xu, Boyong
    Ji, Baochao
    Zhao, Jun
    Huang, Junjie
    Yang, Jianhua
    JOURNAL OF MASS SPECTROMETRY, 2024, 59 (06):
  • [36] Development and Validation of UPLC-MS/MS Method for the Determination of Andrographolide in Human Plasma
    Yuan, Hongchang
    Feng, Jianfang
    Zhang, Dongtao
    Zhang, Jie
    Wang, Yajun
    Qiu, Xiangjun
    LATIN AMERICAN JOURNAL OF PHARMACY, 2015, 34 (06): : 1205 - 1210
  • [37] UPLC-MS/MS determination of 71 neuropsychotropic drugs in human serum
    Jin, Weifeng
    Wang, Jianhua
    Chen, Shuzi
    Chen, Qing
    Li, Dan
    Zhu, Mengyuan
    Fu, Xiaomei
    Huang, Yingyu
    Lin, Ping
    HELIYON, 2024, 10 (12)
  • [38] Validation of Simultaneous Quantitative Method of HIV Protease Inhibitors Atazanavir, Darunavir and Ritonavir in Human Plasma by UPLC-MS/MS
    Mishra, Tulsidas
    Shrivastav, Pranav S.
    SCIENTIFIC WORLD JOURNAL, 2014,
  • [39] Simultaneous determination of benzodiazepines, Z-drugs and metabolite concentrations in human whole blood by UPLC-MS/MS
    Xu, Duoqi
    Sun, Lirui
    Wang, Jifen
    Zhao, Yanjun
    Zhang, Leiping
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2019, 12 (11): : 13135 - 13146
  • [40] Quantification of seven β-lactam antibiotics and two β-lactamase inhibitors in human plasma using a validated UPLC-MS/MS method
    Carlier, Mieke
    Stove, Veronique
    Roberts, Jason A.
    Van de Velde, Eric
    De Waele, Jan J.
    Verstraete, Alain G.
    INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2012, 40 (05) : 416 - 422