A UPLC-MS/MS method for analysis of vancomycin in human cerebrospinal fluid and comparison with the chemiluminescence immunoassay

被引:4
|
作者
Mei, Shenghui [1 ,2 ]
Wang, Jiaqing [1 ]
Zhu, Leting [1 ]
Chen, Ruiling [1 ,2 ]
Li, Xingang [1 ,2 ]
Chen, Kai [3 ]
Chen, Guangqiang [3 ]
Zhou, Jianxin [3 ]
Wang, Qiang [3 ]
Zhao, Zhigang [1 ,2 ]
机构
[1] Capital Med Univ, Beijing Tiantan Hosp, Dept Pharm, 6 Tiantan Xili, Beijing 100050, Peoples R China
[2] Capital Med Univ, Dept Clin Pharmacol, Coll Pharmaceut Sci, Beijing, Peoples R China
[3] Capital Med Univ, Beijing Tiantan Hosp, Intens Care Unit, 6 Tiantan Xili, Beijing 100050, Peoples R China
关键词
cerebrospinal fluid; chemiluminescence immunoassay; method comparison; method development and validation; UPLC-MS/MS; vancomycin; PERFORMANCE LIQUID-CHROMATOGRAPHY; TANDEM MASS-SPECTROMETRY; LC-MS/MS; PLASMA; SERUM; QUANTIFICATION; EXTRACTION; AGREEMENT;
D O I
10.1002/bmc.3939
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Vancomycin (VCM) is clinically used in treating patients with postoperative intracranial infections. The cerebrospinal fluid (CSF) concentration of VCM varies greatly among patients. To guide the dosage regimens, monitoring of VCM in CSF is needed. However a method for analysis of VCM in human CSF is lacking. An ultraperformance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) was developed and validated for analysis of VCM in human CSF, and the agreement of UPLC-MS/MS and chemiluminescence immunoassay (CLIA) in the analysis of CSF VCM was evaluated. The ion transitions were m/z 725.5>144.1 for VCM and m/z 455.2>308.2 for methotrexate (internal standard). The agreement between UPLC-MS/MS and CLIA was evaluated by Bland-Altman plot in 179 samples. The calibration range of the UPLC-MS/MS method was 1-400mg/L. The inaccuracy and imprecision were -0.69-10.80% and <4.95%. The internal standard normalized recovery and matrix factor were 86.14-99.31 and 85.84-92.07%, respectively. The measurements of CLIA and UPLC-MS/MS were strongly correlated (r>0.98). The 95% limit of agreement of the ratio of CLIA to UPLC-MS/MS was 61.66-107.40%. Further studies are warranted to confirm the results.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] UPLC-MS/MS Analysis of Methotrexate in Human Plasma and Comparison with the Fluorescence Polarization Immunoassay
    Mei, Shenghui
    Zhu, Leting
    Li, Xingang
    Wang, Jiaqing
    Jiang, Xueyun
    Chen, Haiyan
    Huo, Jiping
    Yang, Li
    Lin, Song
    Zhao, Zhigang
    ANALYTICAL SCIENCES, 2017, 33 (06) : 665 - 670
  • [2] UPLC-MS/MS Analysis of Methotrexate in Human Plasma and Comparison with the Fluorescence Polarization Immunoassay
    Shenghui Mei
    Leting Zhu
    Xingang Li
    Jiaqing Wang
    Xueyun Jiang
    Haiyan Chen
    Jiping Huo
    Li Yang
    Song Lin
    Zhigang Zhao
    Analytical Sciences, 2017, 33 : 665 - 670
  • [3] Quantitation of osimertinib, alectinib and lorlatinib in human cerebrospinal fluid by UPLC-MS/MS
    de Leeuw, Simon P.
    de Bruijn, Peter
    Koolen, Stijn L. W.
    Dingemans, Anne-Marie C.
    Mathijssen, Ron H. J.
    Veerman, G. D. Marijn
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2023, 225
  • [4] An UPLC-MS/MS method for the analysis of glimepiride and fluoxetine in human plasma
    Qiu, Xiangjun
    Wang, Hong-wei
    Yuan, Ye
    Wang, Ying-fei
    Sun, Ming
    Huang, Xue-sun
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 980 : 16 - 19
  • [5] A sensitive and robust UPLC-MS/MS method for quantitation of estrogens and progestogens in human serum
    Zhang, Junmei
    Tang, Chenxiao
    Oberly, Patrick J.
    Minnigh, Margaret B.
    Achilles, Sharon L.
    Poloyac, Samuel M.
    CONTRACEPTION, 2019, 99 (04) : 244 - 250
  • [6] Development and validation of a rapid, simple, and reliable UPLC-MS/MS method for the quantification of vancomycin in human plasma
    Vinh, Tho Do Chau Minh
    Thanh, Sil Nguyen
    Bich, Tram To
    Diem, Tien Le Thi
    Anh, Thi Huynh Huynh
    Do, Tuyen Ngoc
    PHARMACIA, 2024, 71
  • [7] Simultaneous analysis of losartan, its active metabolite, and hydrochlorothiazide in human plasma by a UPLC-MS/MS method
    Shah, Priyanka A.
    Sharma, Primal
    Shaw, Jaivik V.
    Sanyal, Mallika
    Shrivastav, Pranav S.
    TURKISH JOURNAL OF CHEMISTRY, 2015, 39 (04) : 714 - 733
  • [8] Validation of a method for the targeted analysis of 96 drugs in hair by UPLC-MS/MS
    Montesano, Camilla
    Johansen, Sys Stybe
    Nielsen, Marie Katrine Klose
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 88 : 295 - 306
  • [9] Development of a UPLC-MS/MS Method for Determination of Tacrolimus and Cyclosporine A in Human Whole Blood
    Wang, Shuanghu
    Ding, Ting
    Chen, Jianmiao
    Geng, Peiwu
    Wei, Miaohua
    Wang, Xianqin
    Zhou, Yunfang
    LATIN AMERICAN JOURNAL OF PHARMACY, 2015, 34 (02): : 253 - 258
  • [10] Application of UPLC-MS/MS Method for Analyzing B-vitamins in Human Milk
    Ren Xiang Nan
    Yin Shi An
    Yang Zhen Yu
    Yang Xiao Guang
    Shao Bing
    Ren Yi Ping
    Zhang Jing
    BIOMEDICAL AND ENVIRONMENTAL SCIENCES, 2015, 28 (10) : 738 - 750