The New Approach to a Pattern Recognition of Volatile Compounds: The Inflammation Markers in Nasal Mucus Swabs from Calves Using the Gas Sensor Array

被引:7
|
作者
Kuchmenko, Tatiana [1 ]
Shuba, Anastasiia [1 ]
Umarkhanov, Ruslan [1 ]
Lvova, Larisa [2 ]
机构
[1] Voronezh State Univ Engn Technol VSUET, Dept Phys & Analyt Chem, Revolutsii Ave 19, Voronezh 394036, Russia
[2] Univ Tor Vergata, Dept Chem Sci & Technol, Via Ric Sci 1, I-00133 Rome, Italy
基金
俄罗斯科学基金会;
关键词
gas sensor array; principal component analysis; volatile metabolites; nasal swabs; pattern recognition; TUBE MASS-SPECTROMETRY; ORGANIC-COMPOUNDS; HEALTHY-VOLUNTEERS; EXHALED BREATH; COLORECTAL-CANCER; NOSE; CHROMATOGRAPHY; SYSTEM;
D O I
10.3390/chemosensors9060116
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper discusses the application of two approaches (direct and inverse) to the identification of volatile substances by means of a gas sensor array in a headspace over nasal mucus swab samples taken from calves with differing degrees of respiratory damage. We propose a unique method to visualize sensor array data for quality analysis, based on the spectra of cross mass sensitivity parameters. The traditional method, which requires an initial sensor array trained on the vapors of the individual substances (database accumulation)-with their further identification in the analyzed bio-samples through the comparison of the analysis results to the database-has shown unsatisfactory performance. The proposed inverse approach is more informative for the pattern recognition of volatile substances in the headspace of mucus samples. The projection of the calculated parameters of the sensor array for individual substances in the principal component space, acquired while processing the sensor array output from nasal swab samples, has allowed us to divide animals into groups according to the clinical diagnosis of their lung condition (healthy respiratory system, bronchitis, or bronchopneumonia). The substances detected in the gas phase of the nasal swab samples (cyclohexanone, butanone-2,4-methyl-2-pentanone) were correlated with the clinical state of the animals, and were consistent with the reference data on disease markers in exhaled air established for destructive organism processes.
引用
收藏
页数:16
相关论文
共 12 条
  • [1] Pattern recognition of gas sensor array using characteristics of impedance
    Joo, BS
    Choi, NJ
    Lee, YS
    Lim, JW
    Kang, BH
    Lee, DD
    SENSORS AND ACTUATORS B-CHEMICAL, 2001, 77 (1-2) : 209 - 214
  • [2] Gas identification using micro gas sensor array and neural-network pattern recognition
    Hong, HK
    Shin, HW
    Park, HS
    Yun, DH
    Kwon, CH
    Lee, KC
    Kim, ST
    Moriizumi, T
    SENSORS AND ACTUATORS B-CHEMICAL, 1996, 33 (1-3) : 68 - 71
  • [3] Combustible Gas Discrimination by Pattern Recognition Analysis of Responses from Semiconductor Gas Sensor Array
    Sun, Ping
    Ou, Zhonghua
    Feng, Xing
    SENSORS, MEASUREMENT AND INTELLIGENT MATERIALS, PTS 1-4, 2013, 303-306 : 876 - +
  • [4] DISCRIMINATION OF LIQUOR AROMAS BY PATTERN-RECOGNITION ANALYSIS OF RESPONSES FROM A GAS SENSOR ARRAY
    AISHIMA, T
    ANALYTICA CHIMICA ACTA, 1991, 243 (02) : 293 - 300
  • [5] Identification of plastic toys contaminated with volatile organic compounds using QCM gas sensor array
    Oleneva, E.
    Kuchmenko, T.
    Drozdova, E.
    Legin, A.
    Kirsanov, D.
    TALANTA, 2020, 211
  • [6] Study on volatile markers of pasta quality using GC-MS and a peptide based gas sensor array
    Gaggiotti, Sara
    Shkembi, Blerina
    Sacchetti, Giampiero
    Compagnone, Dario
    LWT-FOOD SCIENCE AND TECHNOLOGY, 2019, 114
  • [7] Detection of volatile organic compounds (VOCs) using SnO2 gas-sensor array and artificial neural network
    Srivastava, AK
    SENSORS AND ACTUATORS B-CHEMICAL, 2003, 96 (1-2) : 24 - 37
  • [8] A New Supervised Learning Approach for Visual Pattern Recognition Using Discrete Circuit Elements and Memristor Array
    Sarkar, Mrinmoy
    Chowdhury, Anik
    Arka, Aqeeb Iqbal
    Rashid, A. B. M. Harun-ur
    TENCON 2017 - 2017 IEEE REGION 10 CONFERENCE, 2017, : 223 - 228
  • [9] Qualitative and quantitative analysis of volatile organic compounds using transient and steady-state responses of a thick-film tin oxide gas sensor array
    Llobet, E
    Brezmes, J
    Vilanova, X
    Sueiras, JE
    Correig, X
    SENSORS AND ACTUATORS B-CHEMICAL, 1997, 41 (1-3) : 13 - 21
  • [10] A study on volatile organic compounds emitted by in-vitro lung cancer cultured cells using gas sensor array and SPME-GCMS
    Thriumani, Reena
    Zakaria, Ammar
    Hashim, Yumi Zuhanis Has-Yun
    Jeffree, Amanina Iymia
    Helmy, Khaled Mohamed
    Kamarudin, Latifah Munirah
    Omar, Mohammad Iqbal
    Shakaff, Ali Yeon Md
    Adom, Abdul Hamid
    Persaud, Krishna C.
    BMC CANCER, 2018, 18