Diagnostic accuracy of fine needle aspiration cytology in parotid gland lesions

被引:1
作者
Hajiioannou, J. [1 ,4 ]
Gkrinia, E. [1 ]
Brotis, G. A. [2 ]
Saratziotis, A. [1 ]
Nepka, C. [3 ]
Korais, C. [1 ]
Skoulakis, C. [1 ]
机构
[1] Univ Hosp Larissa, Dept Head & Neck Surg, Larisa, Greece
[2] Univ Hosp Larissa, Dept Neurosurg, Larisa, Greece
[3] Univ Hosp Larissa, Histopathol Dept, Larisa, Greece
[4] Univ Thessaly, Univ Hosp Larissa, ENT Dept, Biopolis,Otorhinolaryngol Head & Neck Surg,Fac Med, Larisa 41110, Greece
关键词
Fine needle aspiration cytology; FNAC; diagnostic accuracy; sensitivity; specificity; parotid gland; salivary gland tumors; malignant parotid tumors; salivary gland surgery;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: This study aimed to estimate the fine needle aspiration cytology's (FNAC) diagnostic accuracy in differ-entiating neoplastic from inflammatory lesions (Q1) and malignant from their benign counterparts (Q2).Methods: We present a retrospective case series covering a single University Hospital and six attending head and neck surgeons over eight years (January 2011 to July 2017). We concentrated on adults with clinically suspected parotid gland lesions. We offered all patients FNAC biopsy preoperatively, and the final diagnosis was established based on the find-ings of the final histology. The FNAC and histology results were cross-tabulated in a 2 x 2 contingency table, from which we calculated the diagnostic accuracy, sensitivity, specificity, and positive and negative predictive values.Results: From 212 consecutive patients reviewed, and after excluding thirteen cases (8 %) of valid but non-diagnostic FNAC, 161 cases (50 females and 111 males) fulfilled set eligibility criteria. The most common diagnosis was Warthin tumors (53 patients, 34 %), followed by pleomorphic adenomas (52 patients, 33.5 %). The sensitivity and specificity of FNAC in differentiating neoplastic from non-neoplastic lesions and in segregating malignant from benign conditions were estimated to be as high as 50 % and 97 %, and 98 % and 93 %, respectively.Conclusion: FNAC is moderately effective in differentiating non-neoplastic from neoplastic disease and highly accurate in selecting malignant lesions from benign ones. Although the lack of FNAC sensitivity can occasionally be problematic, it still comprises a valuable tool in salivary gland surgery. HIPPOKRATIA 2022, 26 (1):25-31.
引用
收藏
页码:25 / 31
页数:7
相关论文
共 50 条
[21]   Fine-needle aspiration cytology of lymphangioma of the parotid gland in an adult [J].
Henke, AC ;
Cooley, ML ;
Hughes, JH ;
Timmerman, TG .
DIAGNOSTIC CYTOPATHOLOGY, 2001, 24 (02) :126-128
[22]   Diagnostic accuracy of fine-needle aspiration cytology and frozen section in primary parotid carcinoma [J].
Zbären, P ;
Nuyens, M ;
Loosli, H ;
Stauffer, E .
CANCER, 2004, 100 (09) :1876-1883
[23]   Value of fine-needle aspiration cytology of parotid gland masses [J].
Zbären, P ;
Schär, C ;
Hotz, MA ;
Loosli, H .
LARYNGOSCOPE, 2001, 111 (11) :1989-1992
[24]   DIAGNOSTIC ACCURACY OF FINE-NEEDLE ASPIRATION CYTOLOGY IN WARTHIN TUMORS [J].
Veder, Laura L. ;
Kerrebijn, Jeroen D. F. ;
Smedts, Frank M. ;
den Bakker, Michael A. .
HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2010, 32 (12) :1635-1640
[25]   Surgery of benign tumors of the parotid gland. The value of fine needle aspiration cytology [J].
Gehrking, E. ;
Gehrking, I. ;
Moubayed, P. .
HNO, 2007, 55 (03) :195-201
[26]   Diagnostic accuracy of ultrasonography versus fine-needle-aspiration cytology for predicting benign thyroid lesions [J].
Alshoabi, Sultan Abdulwadoud ;
Binnuhaid, Abdulkhaleq Ayedh .
PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2019, 35 (03) :630-635
[27]   Diagnostic accuracy of fine needle aspiration cytology in breast lump [J].
Hassan, Tariq Ch ;
Jamil, Munawar ;
Jamil, Huma ;
Ali, Asghar ;
Sobia, Humaira .
RAWAL MEDICAL JOURNAL, 2012, 37 (02) :168-171
[28]   Diagnostic Accuracy of Fine Needle Aspiration Cytology for High-Grade Salivary Gland Tumors [J].
Bo Young Kim ;
Jiyeon Hyeon ;
Gwanghui Ryu ;
Nayeon Choi ;
Chung-Hwan Baek ;
Young-Hyeh Ko ;
Han-Sin Jeong .
Annals of Surgical Oncology, 2013, 20 :2380-2387
[29]   Diagnostic Accuracy of Fine Needle Aspiration Cytology for High-Grade Salivary Gland Tumors [J].
Kim, Bo Young ;
Hyeon, Jiyeon ;
Ryu, Gwanghui ;
Choi, Nayeon ;
Baek, Chung-Hwan ;
Ko, Young-Hyeh ;
Jeong, Han-Sin .
ANNALS OF SURGICAL ONCOLOGY, 2013, 20 (07) :2380-2387
[30]   Diagnostic accuracy of fine needle aspiration cytology of thyroid nodules [J].
Erkinuresin, Taskin ;
Demirci, Hakan .
DIAGNOSIS, 2020, 7 (01) :61-66