Performance of Four Respiratory Rate Counters to Support Community Health Workers to Detect the Symptoms of Pneumonia in Children in Low Resource Settings: A Prospective, Multicentre, Hospital-Based, Single-Blinded, Comparative Trial

被引:21
作者
Baker, Kevin [1 ,2 ]
Alfven, Tobias [2 ,3 ]
Mucunguzi, Akasiima [4 ]
Wharton-Smith, Alexandra [5 ]
Dantzer, Emily [5 ]
Habte, Tedila [6 ]
Matata, Lena [7 ]
Nanyumba, Diana [4 ]
Okwir, Morris [7 ]
Posada, Monica [5 ]
Sebsibe, Anteneh [6 ]
Nicholson, Jill [1 ]
Marasciulo, Madeleine [8 ]
Izadnegahdar, Rasa [9 ]
Petzold, Max [10 ,11 ]
Kallander, Karin [1 ,2 ]
机构
[1] Malaria Consortium, Green House,244-254 Cambridge Heath Rd, London E2 9DA, England
[2] Karolinska Inst, Dept Publ Hlth Sci, Stockholm, Sweden
[3] Sachs Children & Youth Hosp, Stockholm, Sweden
[4] Malaria Consortium, Kampala, Uganda
[5] Malaria Consortium, Phnom Penh, Cambodia
[6] Malaria Consortium, Addis Ababa, Ethiopia
[7] Malaria Consortium, Juba, South Sudan
[8] Malaria Consortium, Raleigh, NC USA
[9] Bill & Melinda Gates Fdn, Seattle, WA USA
[10] Gothenburg Univ, Gothenburg, Sweden
[11] Univ Witwatersrand, Johannesburg, South Africa
关键词
Childhood pneumonia; Low-income country; Diagnostic tools; Respiratory rate counting; Health worker performance; CHILDHOOD ILLNESS; CASE-MANAGEMENT; INTEGRATED MANAGEMENT; CARE-SEEKING; CALL; VARIABILITY; INFECTIONS; AGREEMENT; MALARIA; ACCESS;
D O I
10.1016/j.eclinm.2019.05.013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Pneumonia is one of the leading causes of death in children under-five globally. The current diagnostic criteria for pneumonia are based on increased respiratory rate (RR) or chest in-drawing in children with cough and/or difficulty breathing. Accurately counting RR is difficult for community health workers (CHWs). Current RR counting devices are frequently inadequate or unavailable. This study analysed the performance of improved RR timers for detection of pneumonia symptoms in low-resource settings. Methods: Four RR timers were evaluated on 454 children, aged from 0 to 59 months with cough and/or difficulty breathing, over three months, by CHWs in hospital settings in Cambodia, Ethiopia, South Sudan and Uganda. The devices were the Mark Two ARI timer (MK2 ARI), counting beads with ARI timer, Rrate Android phone and the Respirometer feature phone applications. Performance was evaluated for agreement with an automated RR reference standard (Masimo Root patient monitoring and connectivity platform with ISA CO2 capnography). This study is registered with ANZCTR [ACTRN12615000348550]. Findings: While most CHWs managed to achieve a RR count with the four devices, the agreement was low for all; the mean difference of RR measurements from the reference standard for the four devices ranged from 0.5 (95% C.I.- 2.2 to 1.2) for the respirometer to 5.5 (95% C.I. 3.2 to 7.8) for Rrate. Performance was consistently lower for young infants (0 to <2 months) than for older children (2 to <= 59 months). Agreement of RR classification into fast and normal breathing was moderate across all four devices, with Cohen's Kappa statistics ranging from 0.41 (SE 0.04) to 0.49 (SE 0.05). Interpretation: None of the four devices evaluated performed well based on agreement with the reference standard. The ARI timer currently recommended for use by CHWs should only be replaced by more expensive, equally performing, automated RR devices when aspects such as usability and duration of the device significantly improve the patient-provider experience. Funding: Bill & Melinda Gates Foundation [OPP1054367]. (C) 2019 The Author(s). Published by Elsevier Ltd.
引用
收藏
页码:20 / 30
页数:11
相关论文
共 54 条
  • [1] Community health workers: A crucial role in newborn health care and survival
    Aboubaker, Samira
    Qazi, Shamim
    Wolfheim, Cathy
    Oyegoke, Adebowale
    Bahl, Rajiv
    [J]. JOURNAL OF GLOBAL HEALTH, 2014, 4 (02) : 32 - 36
  • [2] Poor Agreement and Imprecision of Respiratory Rate Measurements in Children in a Low-Income Setting
    Amirav, Israel
    Masumbuko, Claude Kasereka
    Hawkes, Michael T.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 198 (11) : 1462 - 1463
  • [3] [Anonymous], 2008, COUNTD 2015 TRACK PR
  • [4] Baker Kevin, 2018, JMIR Res Protoc, V7, pe10191, DOI 10.2196/10191
  • [5] Banoo S, 2006, NAT REV MICROBIOL, pS21, DOI [10.1038/nrmicro1523, 10.1038/nrmico1523]
  • [6] RESPIRATORY RATE AND PNEUMONIA IN INFANCY
    BERMAN, S
    SIMOES, EAF
    LANATA, C
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD, 1991, 66 (01) : 81 - 84
  • [7] Childhood Pneumonia and Diarrhoea 2 Interventions to address deaths from childhood pneumonia and diarrhoea equitably: what works and at what cost?
    Bhutta, Zulfiqar A.
    Das, Jai K.
    Walker, Neff
    Rizvi, Arjumand
    Campbell, Harry
    Rudan, Igor
    Black, Robert E.
    [J]. LANCET, 2013, 381 (9875) : 1417 - 1429
  • [8] Can simple mobile phone applications provide reliable counts of respiratory rates in sick infants and children? An initial evaluation of three new applications
    Black, James
    Gerdtz, Marie
    Nicholson, Pat
    Crellin, Dianne
    Browning, Laura
    Simpson, Julie
    Bell, Lauren
    Santamaria, Nick
    [J]. INTERNATIONAL JOURNAL OF NURSING STUDIES, 2015, 52 (05) : 963 - 969
  • [9] Agreement between methods of measurement with multiple observations per individual
    Bland, J. Martin
    Altman, Douglas G.
    [J]. JOURNAL OF BIOPHARMACEUTICAL STATISTICS, 2007, 17 (04) : 571 - 582
  • [10] Agreed Statistics Measurement Method Comparison
    Bland, J. Martin
    Altman, Douglas G.
    [J]. ANESTHESIOLOGY, 2012, 116 (01) : 182 - 185