Monitoring the Quality of Robot-Assisted Pedicle Screw Fixation in the Lumbar Spine by Using a Cumulative Summation Test

被引:103
|
作者
Kim, Ho-Joong [1 ,2 ,3 ]
Lee, Seung Hoo [1 ,2 ,3 ]
Chang, Bong-Soon [2 ,4 ]
Lee, Choon-Ki [2 ,4 ]
Lim, Teck Onn [5 ]
Hoo, Ling Ping [6 ]
Yi, Je-Min [7 ]
Yeom, Jin S. [1 ,2 ,3 ]
机构
[1] Seoul Natl Univ, Coll Med, Spine Ctr, Songnam 463707, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Orthopaed Surg, Songnam 463707, South Korea
[3] Seoul Natl Univ, Bundang Hosp, Songnam 463707, South Korea
[4] Seoul Natl Univ Hosp, Seoul 110744, South Korea
[5] ClinRes Sdn Bhd, Petaling Jaya, Selangor, Malaysia
[6] Stats Consulting Sdn Bhd, Petaling Jaya, Selangor, Malaysia
[7] Kangwon Natl Univ Hosp, Dept Orthopaed Surg, Gangwon Do, South Korea
关键词
robot-assisted pedicle screw fixation; cumulative summation; freehand technique; posterior lumbar interbody fusion; PLACEMENT ACCURACY; LEARNING-CURVE; RISK; PERFORMANCE; NAVIGATION; INSERTION; SURGERY; SYSTEM;
D O I
10.1097/BRS.0000000000000680
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Prospective randomized controlled trial. Objective. The aim of this study was to monitor the quality control of robot-assisted pedicle screw fixation accuracy by using a cumulative summation (CUSUM) test at the initial stage of its application. Summary of Background Data. Although robot-assisted pedicle screw fixation reduces screw misplacement rates and provides critical support for minimally invasive surgical procedures, there have been no reports relating to the monitoring of quality control of the accuracy of this robot-assisted pedicle screw fixation procedure. Methods. Patients with lumbar spinal stenosis scheduled to undergo surgery were randomly and equally assigned through 1:1 allocation to a robot-assisted minimally invasive posterior lumbar interbody fusion (Rom-PLIF) group or a conventional open posterior PLIF using freehand technique group. The accuracy of pedicle screw placement was evaluated using postoperative computed tomography. The primary outcome was the CUSUM analysis for monitoring the quality control of the accuracy of pedicle screw insertion between the Rom-PLIF and conventional open posterior PLIF using freehand technique groups. Results. Of the 80 pedicle screws inserted in each group, 4 screws in the Rom-PLIF group, and 7 in the conventional open PLIF group, breached the pedicle. Of these 11 offending screws, 4 cases were categorized as grade B in the Rom-PLIF group, whereas 6 were grade B and 1 case was grade C in the Com-PLIF group, using the Gertzbein and Robbins classification. Throughout the monitoring period, there was no CUSUM test-derived indication that the quality of performance of the pedicle screw fixation procedure was inadequate in either group. Conclusion. First, this study demonstrates the adequacy of quality control of robot-assisted pedicle screw fixation even early in the application period based on the CUSUM analysis. Second, the CUSUM test can be a useful tool for monitoring of the quality of procedures related with spine surgery.
引用
收藏
页码:87 / 94
页数:8
相关论文
共 50 条
  • [31] Influence of Hydroxyapatite Stick on Pedicle Screw Fixation in Degenerative Lumbar Spine Biomechanical and Radiologic Study
    Shin, Sung Joon
    Lee, Ji-Ho
    Lee, Jae Hyup
    CLINICAL SPINE SURGERY, 2017, 30 (06): : E819 - E826
  • [32] Comparison of the accuracy between robot-assisted and conventional freehand pedicle screw placement: a systematic review and meta-analysis
    Liu, Hao
    Chen, Weikai
    Wang, Zongyi
    Lin, Jun
    Meng, Bin
    Yang, Huilin
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2016, 11 (12) : 2273 - 2281
  • [33] Vibration-Based Milling Condition Monitoring in Robot-Assisted Spine Surgery
    Dai, Yu
    Xue, Yuan
    Zhang, Jianxun
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2015, 20 (06) : 3028 - 3039
  • [34] Ultrasound-Based Robot-Assisted Drilling for Minimally Invasive Pedicle Screw Placement
    Li, Ruixuan
    Davoodi, Ayoob
    Timmermans, Maikel
    Van Assche, Kaat
    Taylan, Orcun
    Scheys, Lennart
    Tummers, Matthias
    Borghesan, Gianni
    Poorten, Emmanuel Vander
    IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS, 2024, 6 (03): : 818 - 828
  • [35] Factors Affecting the Accuracy of Pedicle Screw Placement in Robot-Assisted Surgery A Multicenter Study
    Toossi, Nader
    Vardiman, Arnold B.
    Benech, Carlo A.
    Kanaly, Charles W.
    Maltenfort, Mitchell G.
    Backes, Danielle M.
    Bucklen, Brandon
    SPINE, 2022, 47 (23) : 1613 - 1619
  • [36] Radiographic and clinical outcomes of robot-assisted pedicle screw instrumentation for adolescent idiopathic scoliosis
    Chen, Yuan-Shao
    Lin, Yu-Hsien
    Wu, Yun-Che
    Shih, Cheng-Min
    Chen, Kun-Huei
    Lee, Cheng-Hung
    Lu, Wen-Hsien
    Pan, Chien-Chou
    FRONTIERS IN SURGERY, 2024, 11
  • [37] Robot-assisted Percutaneous Cannulated Screw Fixation of Femoral Neck Fractures: Preliminary Clinical Results
    Duan, Sheng-jun
    Liu, Hua-shui
    Wu, Wen-cheng
    Yang, Kun
    Zhang, Zhen
    Liu, Shi-dong
    ORTHOPAEDIC SURGERY, 2019, 11 (01) : 34 - 41
  • [38] Comparison of rostral facet joint violations in robotic- and navigation-assisted pedicle screw placement for adult lumbar spine instrumentation
    Nilssen, Paal K.
    Narendran, Nakul
    Skaggs, David L.
    Tuchman, Alexander
    Walker, Corey T.
    Perry, Tiffany G.
    SPINE JOURNAL, 2024, 24 (11) : 2102 - 2109
  • [39] Robot-assisted Percutaneous Pedicle Screw Placement Using Three-dimensional Fluoroscopy: A Preliminary Clinical Study
    Tian, Wei
    Fan, Ming-Xing
    Liu, Ya-Jun
    CHINESE MEDICAL JOURNAL, 2017, 130 (13) : 1617 - 1618
  • [40] Robot-assisted Percutaneous Pedicle Screw Placement Using Three-dimensional Fluoroscopy: A Preliminary Clinical Study
    Tian Wei
    Fan Ming-Xing
    Liu Ya-Jun
    中华医学杂志英文版, 2017, 130 (13) : 1617 - 1618