Monitoring the Quality of Robot-Assisted Pedicle Screw Fixation in the Lumbar Spine by Using a Cumulative Summation Test

被引:104
作者
Kim, Ho-Joong [1 ,2 ,3 ]
Lee, Seung Hoo [1 ,2 ,3 ]
Chang, Bong-Soon [2 ,4 ]
Lee, Choon-Ki [2 ,4 ]
Lim, Teck Onn [5 ]
Hoo, Ling Ping [6 ]
Yi, Je-Min [7 ]
Yeom, Jin S. [1 ,2 ,3 ]
机构
[1] Seoul Natl Univ, Coll Med, Spine Ctr, Songnam 463707, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Orthopaed Surg, Songnam 463707, South Korea
[3] Seoul Natl Univ, Bundang Hosp, Songnam 463707, South Korea
[4] Seoul Natl Univ Hosp, Seoul 110744, South Korea
[5] ClinRes Sdn Bhd, Petaling Jaya, Selangor, Malaysia
[6] Stats Consulting Sdn Bhd, Petaling Jaya, Selangor, Malaysia
[7] Kangwon Natl Univ Hosp, Dept Orthopaed Surg, Gangwon Do, South Korea
关键词
robot-assisted pedicle screw fixation; cumulative summation; freehand technique; posterior lumbar interbody fusion; PLACEMENT ACCURACY; LEARNING-CURVE; RISK; PERFORMANCE; NAVIGATION; INSERTION; SURGERY; SYSTEM;
D O I
10.1097/BRS.0000000000000680
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Prospective randomized controlled trial. Objective. The aim of this study was to monitor the quality control of robot-assisted pedicle screw fixation accuracy by using a cumulative summation (CUSUM) test at the initial stage of its application. Summary of Background Data. Although robot-assisted pedicle screw fixation reduces screw misplacement rates and provides critical support for minimally invasive surgical procedures, there have been no reports relating to the monitoring of quality control of the accuracy of this robot-assisted pedicle screw fixation procedure. Methods. Patients with lumbar spinal stenosis scheduled to undergo surgery were randomly and equally assigned through 1:1 allocation to a robot-assisted minimally invasive posterior lumbar interbody fusion (Rom-PLIF) group or a conventional open posterior PLIF using freehand technique group. The accuracy of pedicle screw placement was evaluated using postoperative computed tomography. The primary outcome was the CUSUM analysis for monitoring the quality control of the accuracy of pedicle screw insertion between the Rom-PLIF and conventional open posterior PLIF using freehand technique groups. Results. Of the 80 pedicle screws inserted in each group, 4 screws in the Rom-PLIF group, and 7 in the conventional open PLIF group, breached the pedicle. Of these 11 offending screws, 4 cases were categorized as grade B in the Rom-PLIF group, whereas 6 were grade B and 1 case was grade C in the Com-PLIF group, using the Gertzbein and Robbins classification. Throughout the monitoring period, there was no CUSUM test-derived indication that the quality of performance of the pedicle screw fixation procedure was inadequate in either group. Conclusion. First, this study demonstrates the adequacy of quality control of robot-assisted pedicle screw fixation even early in the application period based on the CUSUM analysis. Second, the CUSUM test can be a useful tool for monitoring of the quality of procedures related with spine surgery.
引用
收藏
页码:87 / 94
页数:8
相关论文
共 33 条
[1]   Transplant center quality assessment using a continuously updatable, risk-adjusted technique (CUSUM) [J].
Axelrod, DA ;
Guidinger, MK ;
Metzger, RA ;
Wiesner, RH ;
Webb, RL ;
Merion, RM .
AMERICAN JOURNAL OF TRANSPLANTATION, 2006, 6 (02) :313-323
[2]   Quantitative and individualized assessment of the learning curve using LC-CUSUM [J].
Biau, D. J. ;
Williams, S. M. ;
Schlup, M. M. ;
Nizard, R. S. ;
Porcher, R. .
BRITISH JOURNAL OF SURGERY, 2008, 95 (07) :925-929
[3]   Monitoring the quality of total hip replacement in a tertiary care department using a cumulative summation statistical method (CUSUM) [J].
Biau, D. J. ;
Meziane, M. ;
Bhumbra, R. S. ;
Dumaine, V. ;
Babinet, A. ;
Anract, P. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (09) :1183-1188
[4]   Using the CUSUM Test to Control the Proportion of Inadequate Open Biopsies of Musculoskeletal Tumors [J].
Biau, David J. ;
Weiss, Kurt R. ;
Bhumbra, Rej S. ;
Davidson, Darin ;
Brown, Chris ;
Wunder, Jay S. ;
Ferguson, Peter C. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (03) :905-914
[5]   Monitoring the one year postoperative infection rate after primary total hip replacement [J].
Biau, David J. ;
Leclerc, Philippe ;
Marmor, Simon ;
Zeller, Valerie ;
Graff, Wilfrid ;
Lhotellier, Luc ;
Leonard, Philippe ;
Mamoudy, Patrick .
INTERNATIONAL ORTHOPAEDICS, 2012, 36 (06) :1155-1161
[6]   Monitoring surgical performance: an application to total hip replacement [J].
Biau, David J. ;
Milet, Alexandre ;
Thevenin, Fabrice ;
Anract, Philippe ;
Porcher, Raphael .
JOURNAL OF EVALUATION IN CLINICAL PRACTICE, 2009, 15 (03) :420-424
[7]   ACCURACY OF PEDICULAR SCREW PLACEMENT INVIVO [J].
GERTZBEIN, SD ;
ROBBINS, SE .
SPINE, 1990, 15 (01) :11-14
[8]   The Learning Curve of Pedicle Screw Placement How Many Screws Are Enough? [J].
Gonzalvo, Augusto ;
Fitt, Gregory ;
Liew, Susan ;
de la Harpe, David ;
Turner, Peter ;
Ton, Lu ;
Rogers, Myron A. ;
Wilde, Peter H. .
SPINE, 2009, 34 (21) :E761-E765
[9]  
Hardoon SL, 2006, J BONE JOINT SURG BR, V88B, P716, DOI 10.1302/0301-620X.88B6
[10]  
Hawkins D. M., 1998, STAT ENGN PHYS SCI