Comparative studies of groundwater vulnerability assessment

被引:20
作者
Maria, Rizka [1 ]
机构
[1] Res Ctr Geotechnol LIPI, Bandung, Indonesia
来源
GLOBAL COLLOQUIUM ON GEOSCIENCES AND ENGINEERING 2017 | 2018年 / 118卷
关键词
AQUIFER VULNERABILITY; DRASTIC MODEL;
D O I
10.1088/1755-1315/118/1/012018
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Pollution of groundwater is a primary issue because aquifers are susceptible to contamination from land use and anthropogenic impacts. Groundwater susceptibility is intrinsic and specific. Intrinsic vulnerability refers to an aquifer that is susceptible to pollution and to the geological and hydrogeological features. Vulnerability assessment is an essential step in assessing groundwater contamination. This approach provides a visual analysis for helping planners and decision makers to achieve the sustainable management of water resources. Comparative studies are applying different methodologies to result in the basic evaluation of the groundwater vulnerability. Based on the comparison of methods, there are several advantages and disadvantages. SI can be overlaid on DRASTIC and Pesticide DRASTIC to extract the divergence in sensitivity. DRASTIC identifies low susceptibility and underestimates the pollution risk while Pesticide DRASTIC and SI represents better risk and is recommended for the future. SINTACS method generates very high vulnerability zones with surface waters and aquifer interactions. GOD method could be adequate for vulnerability mapping in karstified carbonate aquifers at small-moderate scales, and EPIK method can be used for large scale. GOD method is suitable for designing large area such as land management while DRASTIC has good accuracy and more real use in geoenvironmental detailed studies.
引用
收藏
页数:6
相关论文
共 25 条
[1]  
Afonso M.J., 2008, GLOBAL GROUNDWATER R, P259
[2]   Intrinsic Vulnerability Assessment for the Alluvial Aquifer in the Northern Part of Jordan Valley [J].
Al-Amoush, Hani ;
Hammouri, Nezar Atalla ;
Zunic, Franz ;
Salameh, Elias .
WATER RESOURCES MANAGEMENT, 2010, 24 (13) :3461-3485
[3]  
Anane M, 2013, HYDROGEOL J, V21, P715, DOI 10.1007/s10040-013-0952-9
[4]  
[Anonymous], 1987, EPA 600/2-87-035, DOI DOI 10.1029/2011WR010747
[5]  
AWRC-National Water Quality Management Strategy, 1992, GUIDELINES PROTECTIO
[6]   A GIS-based DRASTIC model for assessing aquifer vulnerability in Kakamigahara Heights, Gifu Prefecture, central Japan [J].
Babiker, IS ;
Mohamed, MAA ;
Hiyama, T ;
Kato, K .
SCIENCE OF THE TOTAL ENVIRONMENT, 2005, 345 (1-3) :127-140
[7]  
Barber C., 1993, AGSO, V14, P147
[8]  
Civita M., 1994, AQUIFER VULNERABILIT
[9]  
Civita Massimo V., 2010, Journal of Water Resource and Protection, V2, P14, DOI 10.4236/jwarp.2010.21003
[10]  
Corniello A, 1997, ENGINEERING GEOLOGY AND THE ENVIRONMENT, VOLS 1-3, P1721