A fault tolerant operating system in a doubly fed induction machine under inverter short-circuit faults

被引:0
作者
El Khil, Sejir Khojet [1 ]
Slama-Belkhodja, Ilhem [1 ]
Pietrzak-David, Maria [2 ]
de Fornel, Bernard [2 ]
机构
[1] Ecole Natl Ingenieurs Tunis, Lab Syst Elect, BP 37-1002 Tunis le Belvedere, Tunis, Tunisia
[2] INPT ENSEEIHT, UMR N5828, LEEI, F-31701 Toulouse, France
来源
IECON 2006 - 32ND ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS, VOLS 1-11 | 2006年
关键词
doubly Fed Induction Machine; short-circuit fault; inverter topology and field oriented control reconfiguration;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents an original strategy of fault tolerant operating in case of doubly fed induction machine (DFIM). The considered fault is short-circuit of inverters leg (T-1 and T-2). The proposed strategy permits the reconfiguration management of both inverter topology and DFIM field oriented control. Consequently, the drive continuous operation is guaranteed in the presence of the damaged inverter. Simulation results are presented to emphasize the effectiveness of the proposed method.
引用
收藏
页码:4364 / +
页数:2
相关论文
共 15 条
[1]  
ARANTXA T, 10 MED EL C MELECON, V3
[2]  
BENDL J, ICREPQ 2004
[3]  
ELKHIL SK, 2004, EPE PEMC 04
[4]  
GHOSN R, 2001, THESIS INP ENSHEEIHT
[5]  
HADJIMINAGLOU JR, EPE 1997, P2567
[6]  
KHOJET S, 2005, ELECTRIMACS05
[7]  
LECOCQ D, EPE 1995, P3405
[8]  
MENDES AMS, 2004, ICEM
[9]  
MOREL M, 1998, IEE P ELECT POWER AP, V145
[10]  
RIBEIRO RLA, 2004, IEEE T IND ELECT, V51