Simultaneous Quantitative Analysis of Six Isothiazolinones in Water-Based Adhesive Used for Food Contact Materials by High-Performance Liquid Chromatography-Tandem Mass Spectrometry (HPLC-MS/MS)

被引:13
|
作者
Zhong, Huaining [1 ,2 ]
Li, Zicheng [1 ,2 ]
Chen, Sheng [1 ,2 ]
Zeng, Ying [1 ,2 ]
Zheng, Jianguo [1 ,2 ]
Zeng, You [3 ]
Li, Dan [1 ,2 ]
机构
[1] Guangdong Prov Key Lab Import & Export Tech Measu, Guangzhou 510623, Guangdong, Peoples R China
[2] Guangzhou Customs Dist Technol Ctr, Guangzhou 510623, Guangdong, Peoples R China
[3] Guangzhou Inst Food Inspect, Guangzhou 511400, Guangdong, Peoples R China
来源
MOLECULES | 2019年 / 24卷 / 21期
关键词
analysis; isothiazolinones; water-based adhesive; food contact materials; HPLC-MS/MS; PRODUCTS; METHYLISOTHIAZOLINONE; PRESERVATIVES; COSMETICS; BIOCIDES; ALLERGY; EPIDEMIC; PAINTS; AGENTS;
D O I
10.3390/molecules24213894
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In this study, a target analytical approach using high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was developed to simultaneously determine six isothiazolinones containing 2-Methylisothiazol-3(2H)-one (MI), 5-Chloro-2-methyl-4-isothiazolin-3-one (CMI), 1,2-benzisothiazolin-3-one (BIT), 2-Octyl-3(2H)-isothiazolinone (OIT), Dichlorooctylisothiazolinone (DCOIT), and 2-methyl-1,2-benzisothiazolin-3-one (MBIT) in water-based adhesive used for food contact materials. The main factors affecting extraction efficiency such as extraction method, extraction time, extraction solvent, and solid-liquid ratio have been evaluated by using real adhesive samples. Multiple-reaction monitoring (MRM) was used for the qualitative and quantitative analyses of targeted isothiazolinones. This method was demonstrated as an effective and reliable technique for detecting multiple isothiazolinones with satisfactory recoveries (81.5 similar to 107.3%), and the limits of detection (LOD) and quantification (LOQ) were obtained at a low level. This method was validated and applied to the determination of six isothiazolinones in commercial water-based adhesives. The present results revealed that these adhesives contained a combination of isothiazolinones (BIT, MI, CMI, and MBIT) with the concentration ranging from 2.27 to 123.5 mg/kg. To our knowledge, it is the first time it has been reported that MBIT was detected in water-based adhesives used for food contact materials, which requires a further investigation for its migration to food and the risk to human health.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] The Effect of Dihydromyricetin on the Pharmacokinetics of Fluconazole in Sprague-Dawley Rat Plasma, Based on High-Performance Liquid Chromatography-Tandem Mass Spectrometry
    Liu, Hongchuan
    Dong, Huaihuai
    Guo, Liangjun
    Jin, Yongsheng
    Liu, Lihong
    DRUG DESIGN DEVELOPMENT AND THERAPY, 2023, 17 : 2657 - 2667
  • [42] Optimization of an extraction procedure for the simultaneous quantification of riboflavin, nicotinamide and nicotinic acid in anchovies (Engraulis enrasicolus) by high-performance liquid chromatography-tandem mass spectrometry
    Caprioli, Giovanni
    Sagratini, Gianni
    Vittori, Sauro
    Torregiani, Elisabetta
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2018, 66 : 23 - 29
  • [43] Simultaneous quantitation of azole antifungals, antibiotics, imatinib, and raltegravir in human plasma by two-dimensional high-performance liquid chromatography-tandem mass spectrometry
    Jourdil, Jean-Francois
    Tonini, Julia
    Stanke-Labesque, Francoise
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 919 : 1 - 9
  • [44] Comparison of the efficiency of different extraction methods for the simultaneous determination of mycotoxins and pesticides in milk samples by ultra high-performance liquid chromatography-tandem mass spectrometry
    Aguilera-Luiz, M. M.
    Plaza-Bolanos, P.
    Romero-Gonzalez, R.
    Martinez Vidal, J. L.
    Garrido Frenich, A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 399 (08) : 2863 - 2875
  • [45] Comparison of the efficiency of different extraction methods for the simultaneous determination of mycotoxins and pesticides in milk samples by ultra high-performance liquid chromatography-tandem mass spectrometry
    M. M. Aguilera-Luiz
    P. Plaza-Bolaños
    R. Romero-González
    J. L. Martínez Vidal
    A. Garrido Frenich
    Analytical and Bioanalytical Chemistry, 2011, 399 : 2863 - 2875
  • [46] Analysis of Protein Composition of Red Wine in Comparison with Rose and White Wines by Electrophoresis and High-Pressure Liquid Chromatography-Mass Spectrometry (HPLC-MS)
    Wigand, Petra
    Tenzer, Stefan
    Schild, Hansjoerg
    Decker, Heinz
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2009, 57 (10) : 4328 - 4333
  • [47] A validated high-performance liquid chromatography-tandem mass spectrometry method for simultaneous determination of irinotecan and two major metabolites in rat plasma: Application for the pharmacokinetics study
    Jiang, Liangzhu
    Gu, Nan
    Peng, Yuzhi
    Liao, Yuxin
    Zhou, Limin
    Sun, Yongbing
    SEPARATION SCIENCE PLUS, 2024, 7 (07):
  • [48] Low transition temperature mixture-based extraction of 14 pesticides from tomato samples and their high-performance liquid chromatography-tandem mass spectrometry analysis
    Della Posta, Susanna
    Gallo, Valeria
    Gentili, Alessandra
    Gherardi, Monica
    De Gara, Laura
    Fanali, Chiara
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1717
  • [49] Analysis of sphingolipids in potatoes (Solanum tuberosum L.) and sweet potatoes (Ipomoea batatas (L.) Lam.) by reversed phase high-performance liquid chromatography electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS)
    Bartke, Nana
    Fischbeck, Anne
    Humpf, Hans-Ulrich
    MOLECULAR NUTRITION & FOOD RESEARCH, 2006, 50 (12) : 1201 - 1211
  • [50] Thiol radical-based chemical isotope labelling for sterols quantitation through high performance liquid chromatography-tandem mass spectrometry analysis
    Yu, Yanxin
    Li, Guoliang
    Wu, Di
    Liu, Jianghua
    Chen, Jian
    Hu, Na
    Wang, Honglun
    Wang, Panxue
    Wu, Yongning
    ANALYTICA CHIMICA ACTA, 2020, 1097 : 110 - 119