机构:
Univ Sci & Technol China, Dept Modern Phys, Hefei 230026, Peoples R China
Chinese Acad Sci, Key Lab Technol Particle Detect & Elect, Hefei 230026, Peoples R ChinaUniv Sci & Technol China, Dept Modern Phys, Hefei 230026, Peoples R China
Liu, Shubin
[1
,2
]
Feng, Changqing
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sci & Technol China, Dept Modern Phys, Hefei 230026, Peoples R China
Chinese Acad Sci, Key Lab Technol Particle Detect & Elect, Hefei 230026, Peoples R ChinaUniv Sci & Technol China, Dept Modern Phys, Hefei 230026, Peoples R China
Feng, Changqing
[1
,2
]
An, Qi
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sci & Technol China, Dept Modern Phys, Hefei 230026, Peoples R China
Chinese Acad Sci, Key Lab Technol Particle Detect & Elect, Hefei 230026, Peoples R ChinaUniv Sci & Technol China, Dept Modern Phys, Hefei 230026, Peoples R China
An, Qi
[1
,2
]
Heng, Yuekun
论文数: 0引用数: 0
h-index: 0
机构:
Chinese Acad Sci, Expt Phys Ctr, Inst High Energy Phys, Beijing 100049, Peoples R China
Chinese Acad Sci, Key Lab Technol Particle Detect & Elect, Beijing 100049, Peoples R ChinaUniv Sci & Technol China, Dept Modern Phys, Hefei 230026, Peoples R China
Heng, Yuekun
[3
,4
]
Sun, Shengsen
论文数: 0引用数: 0
h-index: 0
机构:
Chinese Acad Sci, Expt Phys Ctr, Inst High Energy Phys, Beijing 100049, Peoples R China
Chinese Acad Sci, Key Lab Technol Particle Detect & Elect, Beijing 100049, Peoples R ChinaUniv Sci & Technol China, Dept Modern Phys, Hefei 230026, Peoples R China
Sun, Shengsen
[3
,4
]
机构:
[1] Univ Sci & Technol China, Dept Modern Phys, Hefei 230026, Peoples R China
[2] Chinese Acad Sci, Key Lab Technol Particle Detect & Elect, Hefei 230026, Peoples R China
[3] Chinese Acad Sci, Expt Phys Ctr, Inst High Energy Phys, Beijing 100049, Peoples R China
[4] Chinese Acad Sci, Key Lab Technol Particle Detect & Elect, Beijing 100049, Peoples R China
Charge measurement;
particle identification;
time measurement;
time-of-flight;
D O I:
10.1109/TNS.2009.2034520
中图分类号:
TM [电工技术];
TN [电子技术、通信技术];
学科分类号:
0808 ;
0809 ;
摘要:
A time-of-flight (TOF) readout system has been developed for a Beijing Spectrometer (BES III). This paper will present an overview of the entire TOF readout system design and its performance in the operation. In a BES III TOF detector, a total of 448 photomultiplier tubes (PMTs) have been installed in barrel and end-cap sections. The corresponding 448 channels' readout electronics aimed precisely to measure the arrival time of PMT signals from the TOF detector is mainly housed in two VME64xP crates, each crate containing 14 FEE modules, 14 FEE rear modules, one Fast Control module (FastCtrl), one Clock module, and one Power-PC interface module. Due to the structure of the spectrometer, the two VME crates with 448 channels of readout electronics are placed in two locations; each is 18 m away from the TOF detector. In order to increase the capability of noise immunization and achieve better signal-to-noise ratio, each channel has a preamplifier equipped to PMT base. The preamplifier drives the differential signals over 18 m of shielded twisted-pair cables to the VME crates. The readout system achieved a timing resolution of 25 ps after time-walk and INL corrections. The amplitude-dependent time-walk correction is accomplished by measuring corresponding pulse height. Achieved pulse-height resolution is better than 10 mV in a dynamic range 180-5000 mV. The whole TOF readout system was installed in the spectrometer and has been in operation steadily since then, with the performance well meeting the requirements of the physics experiments.