Instrument for near infrared emission spectroscopic probing of human fingertips in vivo

被引:30
作者
Chaiken, J. [1 ,2 ]
Deng, Bin [1 ,2 ]
Bussjager, Rebecca J. [3 ]
Shaheen, George [3 ]
Rice, David [4 ]
Stehlik, Dave [4 ]
Fayos, John [4 ]
机构
[1] Syracuse Univ, Dept Chem, Ctr Sci & Technol, Syracuse, NY 13244 USA
[2] Syracuse Univ, Dept Biomed Engn, Ctr Sci & Technol, Syracuse, NY 13244 USA
[3] LighTouch Med Inc, Syracuse, NY 13201 USA
[4] Crit Link LLC, Syracuse, NY 13211 USA
关键词
biomedical optical imaging; bio-optics; blood; fluorescence; infrared spectroscopy; Mie scattering; Raman spectra; Rayleigh scattering; skin; RAMAN-SPECTROSCOPY;
D O I
10.1063/1.3314290
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We present instrumentation for probing of volar side fingertip capillary beds with free space coupled near infrared light while collecting Raman, Rayleigh, and Mie scattered light as well as fluorescence. Fingertip skin capillary beds are highly vascularized relative to other tissues and present a desirable target for noninvasive probing of blood. But human hands and fingers in particular are also highly idiosyncratic body parts requiring specific apparatus to allow careful and methodical spectoscopic probing. The apparatus includes means for precise and reproducible placement of the tissues relative to the optical aperture. Appropriate means are provided for applying and maintaining pressure to keep surface tissues immobile during experiments while obtaining the desired blood content and flow. Soft matter, e.g., skin, extrudes into the aperture in response to any applied pressure, e.g., to keep the tissue in registration with the optical system, so the position, contact area, pressure, and force are continuously measured and recorded to produce feedback for an actuator applying force and to discern the compliance of the test subject. The compliance strongly affects the reliability of the measurement and human factors must be adequately managed in the case of in vivo probing. The apparatus produces reproducible observations and measurements that allow consistent probing of the tissues of a wide range of skin types.
引用
收藏
页数:11
相关论文
共 22 条
[1]  
[Anonymous], 2005, Raman spectroscopy for chemical analysis M
[2]  
Ashbaugh David R., Quantitative-Qualitative Friction Ridge Analysis, V1st
[3]   Turbidity-Corrected Raman Spectroscopy for Blood Analyte Detection [J].
Barman, Ishan ;
Singh, Gajendra P. ;
Dasari, Ramachandra R. ;
Feld, Michael S. .
ANALYTICAL CHEMISTRY, 2009, 81 (11) :4233-4240
[4]  
Brandis K., FLUID PHYSL
[5]  
Burmeister JJ, 1999, CLIN CHEM, V45, P1621
[6]   Effect of hemoglobin concentration variation on the accuracy and precision of glucose analysis using tissue modulated, noninvasive, in vivo Raman spectroscopy of human blood:: a small clinical study -: art. no. 031111 [J].
Chaiken, J ;
Finney, W ;
Knudson, PE ;
Weinstock, RS ;
Khan, M ;
Bussjager, RJ ;
Hagrman, D ;
Hagrman, P ;
Zhao, YW ;
Peterson, CM ;
Peterson, K .
JOURNAL OF BIOMEDICAL OPTICS, 2005, 10 (03)
[7]   Progress in the noninvasive, in-vivo, tissue modulated Raman spectroscopy of human blood [J].
Chaiken, J ;
Finney, WF ;
Yang, XK ;
Knudson, PE ;
Peterson, KP ;
Peterson, CM ;
Weinstock, RS ;
Hagrman, D .
BIOMEDICAL DIAGNOSTIC, GUIDANCE, AND SURGICAL-ASSIST SYSTEMS III, 2001, 4254 :216-227
[8]   Noninvasive, in vivo, tissue modulated near infrared vibrational spectroscopic study of mobile and static tissues: blood chemistry [J].
Chaiken, J ;
Finney, WF ;
Peterson, CM ;
Peterson, KP ;
Knudson, PE ;
Weinstock, RS ;
Lein, P .
BIOMEDICAL SPECTROSCOPY: VIBRATIONAL SPECTROSCOPY AND OTHER NOVEL TECHNIQUES, 2000, 3918 :135-143
[9]  
CHAIKEN J, J BIOMED OPT UNPUB
[10]  
CHAIKEN J, 2001, Patent No. 6223063