摘要
Enriched B-10 (94.14 atom %) was supplied to coffee plantlets for three months. Then boron isotope ratios were determined in the leaf cell compartments, cell wall, nuclei and chloroplast, after a sub-cellular fractionation procedure. The isotopic measurements were performed by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) provided with a direct injection nebulizer (DIN), introducing a sample volume of 50 muL. Isotopic ratios from 1.002 to 1.326 were determined with precision characterized by RSD lower than 1.5% for the enriched cell fractions with B concentrations ranging from 3.3 to 10.8 mug g(-1). The detection limit (3sigma) was 0.5 ng B mL(-1). The average enrichments in B-10 atom % found in the cell walls, nuclei and chloroplasts were 46.7, 44.5 and 48.8, respectively.
引用
收藏
页码:269 / 273
页数:5
相关论文
共 19 条
[1]   Elimination of boron memory effect in inductively coupled plasma-mass spectrometry by addition of ammonia [J].
Al-Ammar, A ;
Gupta, RK ;
Barnes, RM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (07) :1077-1084
[2]   Improving boron isotope ratio measurement precision with quadrupole inductively coupled plasma-mass spectrometry [J].
Al-Ammar, A ;
Reitznerová, E ;
Barnes, RM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (12) :1861-1867
[3]   Boron isotope ratios in plants enriched in 10B as determined by direct injection nebulization inductively coupled plasma mass spectrometry [J].
Bellato, ACS ;
Menegário, AA ;
Giné, MF .
COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS, 2001, 32 (11-12) :1981-1990
[4]   INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY - A REVIEW [J].
EVANS, EH ;
GIGLIO, JJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (01) :1-18
[5]   IMPROVED BORON DETERMINATION IN BIOLOGICAL-MATERIAL BY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
EVANS, S ;
KRAHENBUHL, U .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (11) :1249-1253
[7]   DETERMINATION OF BORON IN FRESH AND SALINE WATERS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
GREGOIRE, DC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1990, 5 (07) :623-626
[8]  
Heumann KG, 1998, J ANAL ATOM SPECTROM, V13, P1001
[9]   Measurement of total boron and 10B concentration and the detection and measurement of elevated 10B levels in biological samples by inductively coupled plasma mass spectrometry using the determination of 10B:11B ratios [J].
Moreton, JA ;
Delves, HT .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (10) :1545-1556
[10]   Boron determination in biological materials by inductively coupled plasma atomic emission and mass spectrometry: Effects of sample dissolution methods [J].
Nyomora, AMS ;
Sah, RN ;
Brown, PH ;
Miller, RO .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (08) :1185-1191