共 50 条
Late intraocular lens exchange in dissatisfied patients with multifocal intraocular lens implantation
被引:2
|作者:
Kuo, Yu-Wei
[1
]
Hou, Yu-Chih
[1
,2
,3
]
机构:
[1] Cathay Gen Hosp, Dept Ophthalmol, 280,Ren Ai Rd,Sect 4, Taipei, Taiwan
[2] Natl Taiwan Univ, Natl Taiwan Univ Hosp, Coll Med, Dept Ophthalmol, Taipei, Taiwan
[3] Fu Jen Catholic Univ, Coll Med, Dept Ophthalmol, New Taipei, Taiwan
关键词:
Capsulotomy;
intraocular lens exchange;
multifocal intraocular lenses;
optic capture;
COMPLICATIONS;
OUTCOMES;
D O I:
10.4103/tjo.tjo_55_20
中图分类号:
R77 [眼科学];
学科分类号:
100212 ;
摘要:
Intraocular lens (IOL) exchange may be required after multifocal IOL implantation due to dissatisfaction. Late IOL exchange is more challenging when it is done with capsulotomy. We presented a retrospective case series study enrolling four consecutive eyes reviewing late IOL exchange due to decreased vision and dysphotopsia. High residual hyperopia, astigmatism, and IOL tilt occurred in 3 eyes, respectively. The mean time to the IOL exchange was 15.8 +/- 10.63 months. After separation of the adhesions by visco-dissection assisted with a 27-gaze needle and sinskey hook, IOL was explanted. One-piece IOL was implanted in the bag in two eyes without posterior capsulotomy, whereas three-piece IOL was implanted in the sulcus after viscoelastic tamponade in the other 2 eyes with capsulotomy. No complication occurred and dysphotopsia disappeared. The mean logarithm of the minimum angle of resolution best-corrected visual acuity significantly improved from 0.33 +/- 0.12 preoperatively to 0.11 +/- 0.13 postoperatively. In conclusion, late IOL exchange could be safely performed with proper technique and achieve good results.
引用
收藏
页码:109 / 112
页数:4
相关论文