Vaginal vault brachytherapy: the effect of varying bladder volumes on normal tissue dosimetry

被引:22
作者
Hoskin, PJ [1 ]
Vidler, K [1 ]
机构
[1] Mt Vernon Hosp, Mt Vernon Ctr Canc Treatment, Northwood HA6 2RN, Middx, England
关键词
D O I
10.1259/bjr.73.872.11026862
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study was designed to assess the impact of bladder volume on dosimetry to critical normal structures in vaginal vault brachytherapy using a single line source vaginal applicator. 30 consecutive patients undergoing vaginal vault brachytherapy were studied by CT scanning with the applicator in situ and the bladder empty and then with the bladder containing either 35 ml of water (10 patients), 70 ml of water (10 patients) or 100 ml of water (10 patients). The scans were then analysed with isodose distributions overlayed to determine changes in dosimetry. No effect on bladder dose was seen with increasing volume compared with the empty bladder; however, there was a reduction in amount of small bowel within the high dose treatment region as bladder volume increased. With 100 ml bladder volume, the reduction reached 57.5% compared with the empty bladder. We conclude that vaginal vault brachytherapy should be undertaken with a bladder volume of at least 100 ml, which will considerably reduce the amount of small bowel ill the irradiation volume with no increase in bladder dose.
引用
收藏
页码:864 / 866
页数:3
相关论文
共 11 条
[1]  
AALDERS J, 1980, OBSTET GYNECOL, V56, P419
[2]  
Bliss P, 1992, Clin Oncol (R Coll Radiol), V4, P373, DOI 10.1016/S0936-6555(05)81130-6
[3]  
HOSKIN PJ, 1998, J BRACHYTHER INT, V14, P1
[4]   RESULTS OF INTRACAVITARY RADIUM TREATMENT FOR ADENOCARCINOMA OF THE BODY OF THE UTERUS [J].
JONES, DA ;
STOUT, R .
CLINICAL RADIOLOGY, 1986, 37 (02) :169-171
[5]   ENDOMETRIAL CARCINOMA - HIGH DOSE-RATE BRACHYTHERAPY IN COMBINATION WITH EXTERNAL IRRADIATION - A MULTIVARIATE-ANALYSIS OF RELAPSES [J].
LYBEERT, MLM ;
VANPUTTEN, WLJ ;
RIBOT, JG ;
CROMMELIN, MA .
RADIOTHERAPY AND ONCOLOGY, 1989, 16 (04) :245-252
[6]   SYSTEMATIC IRRADIATION OF THE VAGINAL VAULT IN STAGE-I ENDOMETRIAL CARCINOMA [J].
NGUYEN, TD ;
FROISSART, D ;
PANIS, X .
RADIOTHERAPY AND ONCOLOGY, 1988, 12 (03) :171-176
[7]   HDR - FORGET NOT TIME AND DISTANCE [J].
ORTON, CG .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (05) :1131-1132
[8]  
Palmer J, 1990, Med Dosim, V15, P193
[9]   EFFECT OF BLADDER DISTENSION ON DOSIMETRY IN GYNECOLOGICAL IMPLANTS [J].
PILEPICH, MV ;
PRASAD, S ;
MADOCJONES, H ;
BEDWINEK, JM .
RADIOLOGY, 1981, 140 (02) :516-518
[10]   TREATING THE VAGINAL VAULT IN CARCINOMA OF THE ENDOMETRIUM USING THE BUCHLER AFTERLOADING SYSTEM [J].
THOMAS, H ;
PICKERING, DGL ;
DUNN, P ;
KAM, KC ;
STEWART, JSW ;
LAMBERT, HE .
BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (767) :1044-1048