The quantification of human chorionic gonadotropin by two isotope dilution mass spectrometry methods

被引:5
作者
Huang, Ting [1 ]
Zhang, Xiaoguang [2 ]
Song, Dewei [1 ]
Wu, Liqing [3 ]
Li, Xiaomin [1 ]
Yang, Yi [2 ]
Quan, Can [1 ]
Li, Hongmei [1 ]
机构
[1] Natl Inst Metrol, Div Chem Metrol & Analyt Sci, Beijing 100013, Peoples R China
[2] Beijing Univ Chem Technol, Coll Sci, Beijing 100029, Peoples R China
[3] Natl Inst Metrol, Div Med & Biol Measurement, Beijing 100013, Peoples R China
基金
中国国家自然科学基金;
关键词
CLINICAL PROTEOMICS;
D O I
10.1039/c4ay01488j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two isotope dilution mass spectrometry (IDMS) methods were established and compared for absolute quantification of the mass fraction of an important clinical diagnostic marker, i.e. human chorionic gonadotropin (hCG), by employing hydrolysis and enzymatic digestion. In the first method, after hydrolysis of the protein, amino acids were separated by high-performance liquid chromatography (HPLC) and then detected by tandem mass spectrometry (MS) with multiple reaction monitoring (MRM) for phenylalanine, proline, valine and the internal standards (C-13(9)-phenylalanine, C-13(5)-proline and C-13(5)-valine). In the second method, after enzyme digestion, the signature peptide (VLQGVLPALPQVVCNYR, m/z = 964 -> 1036) and the internal standard (d(10)-VLQGVL*PALPQVVCNYR, m/z = 970 -> 1317) were separated by HPLC, and then detected by MS with MRM. By optimizing the key factors of hydrolysis and enzymatic digestion, the mass fractions of hCG detected by these two methods are consistent. The mass fraction of hCG by hydrolysis is 0.6150 g g(-1) (expanded uncertainty = 0.016 g g(-1), k = 2), the mass fraction of hCG by enzyme digestion is 0.5810 g g(-1) (expanded uncertainty - 0.072 g g(-1), k - 2), and the weighted average mass fraction is 0.6126 g g(-1) (expanded uncertainty = 0.016 g g(-1), k = 2). This study would benefit the absolute quantification of clinical marker proteins, and underpin the development of relative certified reference materials of clinical diagnostic markers to ensure the accuracy, comparability and traceability of medical laboratory testing.
引用
收藏
页码:8690 / 8697
页数:8
相关论文
共 21 条
[1]   Multi-site assessment of the precision and reproducibility of multiple reaction monitoring-based measurements of proteins in plasma [J].
Addona, Terri A. ;
Abbatiello, Susan E. ;
Schilling, Birgit ;
Skates, Steven J. ;
Mani, D. R. ;
Bunk, David M. ;
Spiegelman, Clifford H. ;
Zimmerman, Lisa J. ;
Ham, Amy-Joan L. ;
Keshishian, Hasmik ;
Hall, Steven C. ;
Allen, Simon ;
Blackman, Ronald K. ;
Borchers, Christoph H. ;
Buck, Charles ;
Cardasis, Helene L. ;
Cusack, Michael P. ;
Dodder, Nathan G. ;
Gibson, Bradford W. ;
Held, Jason M. ;
Hiltke, Tara ;
Jackson, Angela ;
Johansen, Eric B. ;
Kinsinger, Christopher R. ;
Li, Jing ;
Mesri, Mehdi ;
Neubert, Thomas A. ;
Niles, Richard K. ;
Pulsipher, Trenton C. ;
Ransohoff, David ;
Rodriguez, Henry ;
Rudnick, Paul A. ;
Smith, Derek ;
Tabb, David L. ;
Tegeler, Tony J. ;
Variyath, Asokan M. ;
Vega-Montoto, Lorenzo J. ;
Wahlander, Asa ;
Waldemarson, Sofia ;
Wang, Mu ;
Whiteaker, Jeffrey R. ;
Zhao, Lei ;
Anderson, N. Leigh ;
Fisher, Susan J. ;
Liebler, Daniel C. ;
Paulovich, Amanda G. ;
Regnier, Fred E. ;
Tempst, Paul ;
Carr, Steven A. .
NATURE BIOTECHNOLOGY, 2009, 27 (07) :633-U85
[2]   Development of hemoglobin A1c certified reference material by liquid chromatography isotope dilution mass spectrometry [J].
Bi, Jiaming ;
Wu, Liqing ;
Yang, Bin ;
Yang, Yi ;
Wang, Jing .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 403 (02) :549-554
[3]   PREPARATION AND CHARACTERIZATION OF AN IMPROVED BETA-COOH-TERMINAL IMMUNOGEN FOR GENERATION OF SPECIFIC AND SENSITIVE ANTISERA TO HUMAN CHORIONIC-GONADOTROPIN [J].
BIRKEN, S ;
CANFIELD, R ;
AGOSTO, G ;
LEWIS, J .
ENDOCRINOLOGY, 1982, 110 (05) :1555-1563
[4]  
Butler SA, 2001, CLIN CHEM, V47, P2131
[5]  
Canfield R., 1976, Peptide Hormones, P299
[6]   A biochemical perspective on the use of tandem mass spectrometry for newborn screening and clinical testing [J].
Chace, DH ;
Kalas, TA .
CLINICAL BIOCHEMISTRY, 2005, 38 (04) :296-309
[7]   Hyperglycosylated hCG (Invasive Trophoblast Antigen, ITA) a key antigen for early pregnancy detection [J].
Cole, LA ;
Khanlian, SA ;
Sutton, JM ;
Davies, S ;
Stephens, ND .
CLINICAL BIOCHEMISTRY, 2003, 36 (08) :647-655
[8]   Immunoaffinity extraction and tandem mass spectrometric analysis of human chorionic gonadotropin in doping analysis [J].
Gam, LH ;
Tham, SY ;
Latiff, A .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 792 (02) :187-196
[9]   Differential expression of human chorionic gonadotropin (hCG) glycosylation isoforms in failing and continuing pregnancies: preliminary characterization of the hyperglycosylated hCG epitope [J].
Kovalevskaya, G ;
Birken, S ;
Kakuma, T ;
Ozaki, N ;
Sauer, M ;
Lindheim, S ;
Cohen, M ;
Kelly, A ;
Schlatterer, J ;
O'Connor, JF .
JOURNAL OF ENDOCRINOLOGY, 2002, 172 (03) :497-506
[10]  
Laidler P., 1996, P 14 COL WORKSH DOP, P285