NuMED Covered Cheatham- Platinum Stent™ for the Treatment or Prevention of Right Ventricular Outflow Tract Conduit Disruption During Transcatheter Pulmonary Valve Replacement

被引:30
作者
Bishnoi, Ram N. [1 ]
Jones, Thomas K. [2 ]
Kreutzer, Jacqueline [3 ]
Ringel, Richard E. [1 ]
机构
[1] Bloomberg Childrens Ctr, Johns Hopkins Sch Med, Div Pediat Cardiol, Baltimore, MD 21287 USA
[2] Univ Washington, Sch Med, Seattle Childrens Hosp, Div Pediat Cardiol, Seattle, WA USA
[3] Univ Pittsburgh, Childrens Hosp Pittsburgh, Sch Med, Div Pediat Cardiol,UPMC, Pittsburgh, PA USA
关键词
covered cheatham-platinum stent; melody TPV (R); right ventricular outflow tract conduit; transcatheter pulmonary valve replacement; AORTIC COARCTATION; IMPLANTATION; TRIAL; DYSFUNCTION;
D O I
10.1002/ccd.25682
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ObjectiveRetrospectively assess the frequency of right ventricular outflow tract (RVOT) conduit disruption during transcatheter pulmonary valve replacement (TPVR) and the effectiveness and safety of NuMED Covered Cheatham-Platinum Stents (CCPS) for its prevention or treatment. BackgroundThere have been no published reports to date describing the safety and effectiveness of covered stents to prevent or treat RVOT conduit disruption during TPVR. MethodsData regarding 251 TPVR procedures performed at multiple US investigational sites were retrospectively reviewed to explore the incidence and potential predictors of conduit disruption. In addition, data on the use of 69 CCPS implanted in 50 patients during TPVR was reviewed. ResultsThe overall incidence of conduit disruption requiring intervention was 6%. The only predictor identified was a very elevated RVOT conduit systolic pressure gradient. A pre-existing conduit tear was present in nine, while 31 developed tears after conduit dilation and three, after TPVR. The CCPS was used prophylactically in seven. Conduit tears were prevented or repaired in 49/50 patients. No CCPS-related acute complications were reported. At 6-month follow-up, no patient had more than mild pulmonary regurgitation and the mean Doppler RVOT gradient (12.75.8 mm Hg) comparing favorably with that reported in the Melody TPV (R) IDE trial (20.0 +/- 8.6 mm Hg). ConclusionCCPS implantation can successfully treat RVOT conduit disruption without negative impact on the TPV function. This retrospective analysis suggests high RVOT conduit systolic pressure gradient is a risk factor for conduit tears during TPVR. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:421 / 427
页数:7
相关论文
共 13 条
[1]   Percutaneous replacement of pulmonary valve in a right-ventricle to pulmonary-artery prosthetic conduit with valve dysfunction [J].
Bonhoeffer, P ;
Boudjemline, Y ;
Saliba, Z ;
Merckx, J ;
Aggoun, Y ;
Bonnet, D ;
Acar, P ;
Le Bidois, J ;
Sidi, D ;
Kachaner, J .
LANCET, 2000, 356 (9239) :1403-1405
[2]   Transcatheter implantation of a bovine valve in pulmonary position - A lamb study [J].
Bonhoeffer, P ;
Boudjemline, Y ;
Saliba, Z ;
Hausse, AO ;
Aggoun, Y ;
Bonnet, D ;
Sidi, D ;
Kachaner, J .
CIRCULATION, 2000, 102 (07) :813-816
[3]   The CP stent - short, long, covered - for the treatment of aortic coarctation, stenosis of pulmonary arteries and caval veins, and Fontan anastomosis in children and adults: an evaluation of 60 stents in 53 patients [J].
Ewert, P ;
Schubert, S ;
Peters, B ;
Abdul-Khaliq, H ;
Nagdyman, N ;
Lange, PE .
HEART, 2005, 91 (07) :948-953
[4]   Self-expanding and balloon expandable covered stents in the treatment of aortic coarctation with or without aneurysm formation [J].
Kenny, Damien ;
Margey, Ronan ;
Turner, Mark S. ;
Tometzki, Andrew J. ;
Walsh, Kevin P. ;
Martin, Robin P. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 72 (01) :65-71
[5]   Percutaneous pulmonary valve implantation impact of evolving technology and learning curve on clinical outcome [J].
Lurz, Philipp ;
Coats, Louise ;
Khambadkone, Sachin ;
Nordmeyer, Johannes ;
Boudjemline, Younes ;
Schievano, Silvia ;
Muthurangu, Vivek ;
Lee, Twin Yen ;
Parenzan, Giovanni ;
Derrick, Graham ;
Cullen, Seamus ;
Walker, Fiona ;
Tsang, Victor ;
Deanfield, John ;
Taylor, Andrew M. ;
Bonhoeffer, Philipp .
CIRCULATION, 2008, 117 (15) :1964-1972
[6]   Use of the melody™ transcatheter pulmonary valve as a "Covered stent" to repair conduit perforation during pulmonary valve implantation [J].
Mahgerefteh, Joseph ;
Sutton, Nicole J. ;
Pass, Robert H. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (06) :980-984
[7]  
McElhinney DB, 2011, CIRC-CARDIOVASC INTE, V4, P1
[8]   Stent Fracture, Valve Dysfunction, and Right Ventricular Outflow Tract Reintervention After Transcatheter Pulmonary Valve Implantation Patient-Related and Procedural Risk Factors in the US Melody Valve Trial [J].
McElhinney, Doff B. ;
Cheatham, John P. ;
Jones, Thomas K. ;
Lock, James E. ;
Vincent, Julie A. ;
Zahn, Evan M. ;
Hellenbrand, William E. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (06) :602-U130
[9]   Short- and Medium-Term Outcomes After Transcatheter Pulmonary Valve Placement in the Expanded Multicenter US Melody Valve Trial [J].
McElhinney, Doff B. ;
Hellenbrand, William E. ;
Zahn, Evan M. ;
Jones, Thomas K. ;
Cheatham, John P. ;
Lock, James E. ;
Vincent, Julie A. .
CIRCULATION, 2010, 122 (05) :507-U132
[10]   Endovascular stenting of obstructed right ventricle-to-pulmonary artery conduits - A 15-year experience [J].
Peng, Lynn F. ;
McElhinney, Doff B. ;
Nugent, Alan W. ;
Powell, Andrew J. ;
Marshall, Audrey C. ;
Bacha, Emile A. ;
Lock, James E. .
CIRCULATION, 2006, 113 (22) :2598-2605