A Simple, Cost-Effective Sensor for Detecting Lead Ions in Water Using Under-Potential Deposited Bismuth Sub-Layer with Differential Pulse Voltammetry (DPV)

被引:20
作者
Dai, Yifan
Liu, Chung Chiun [1 ]
机构
[1] Case Western Reserve Univ, Dept Chem & Biomol Engn, 10900 Euclid Ave, Cleveland, OH 44106 USA
关键词
under-potential deposition; bismuth sub-layer; lead ions; DPV; HEAVY-METAL IONS; ELECTROCHEMICAL DETECTION; UNDERPOTENTIAL DEPOSITION; OXYGEN REDUCTION; SINGLE-USE; ELECTRODES; MICROELECTRODE; MONOLAYERS; SURFACES; AU(111);
D O I
10.3390/s17050950
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This research has developed a simple to use, cost effective sensor system for the detection of lead ions in tap water. An under-potential deposited bismuth sub-layer on a thin gold film based electrochemical sensor was designed, manufactured, and evaluated. Differential pulse voltammetry (DPV) measurement technique was employed in this detection. Tap water from the Cleveland, OH, USA regional water district was the test medium. Concentrations of lead ion in the range of 8 x 10(-7) M to 5 x 10(-4) M were evaluated, showing a good sensitivity over this concentration range. The calibration curve for the DPV measurements of lead ions in tap water showed excellent reproducibility with R-2 value of 0.970. This DPV detection system required 3-6 min to complete the detection measurement. A longer measurement time of 6 min was used for the lower lead ion concentration. The selectivity of this lead ion sensor was very good, and Fe III, Cu II, Ni II, and Mg II at a concentration level of 5 x 10(-4) M did not interfere with the lead ion measurement.
引用
收藏
页数:11
相关论文
共 38 条
[1]   OXYGEN REDUCTION ON ELECTRODE SURFACES MODIFIED BY FOREIGN METAL AD-ATOMS - LEAD AD-ATOMS ON GOLD [J].
ADZIC, RR ;
TRIPKOVIC, AV ;
MARKOVIC, NM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1980, 114 (01) :37-51
[2]  
[Anonymous], 2004, Blood lead levels in residents of homes with elevated lead in tap water - district of Columbia 2004, V53, P268
[3]   Bismuth-modified electrodes for lead detection [J].
Arduini, Fabiana ;
Calvo, Josefina Quintana ;
Amine, Aziz ;
Palleschi, Giuseppe ;
Moscone, Danila .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2010, 29 (11) :1295-1304
[4]   Invertase inhibition based electrochemical sensor for the detection of heavy metal ions in aqueous system: Application of ultra-microlelectrode to enhance sucrose biosensor's sensitivity [J].
Bagal-Kestwal, Dipali ;
Karve, Meena S. ;
Kakade, Bhalchandra ;
Pillai, Vijayamohanan K. .
BIOSENSORS & BIOELECTRONICS, 2008, 24 (04) :657-664
[5]  
Bockris J. O. M., 2000, Modern Electrochemistry 2A: Fundamentals of Electrodics, V2nd
[6]   Preparation, characterization and application of alkanethiol self-assembled monolayers modified with tetrathiafulvalene and glucose oxidase at a gold disk electrode [J].
Campuzano, S ;
Gálvez, R ;
Pedero, M ;
de Villena, FJM ;
Pingarrón, JM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 526 (1-2) :92-100
[7]   Electrochemical detection of D-dimer as deep vein thrombosis marker using single-chain D-dimer antibody immobilized on functionalized polypyrrole [J].
Chebil, S. ;
Hafaiedh, I. ;
Sauriat-Dorizon, H. ;
Jaffrezic-Renault, N. ;
Errachid, A. ;
Ali, Z. ;
Korri-Youssoufi, H. .
BIOSENSORS & BIOELECTRONICS, 2010, 26 (02) :736-742
[8]   ELECTRODEPOSITED BISMUTH MONOLAYERS ON AU(111) ELECTRODES - COMPARISON OF SURFACE X-RAY-SCATTERING, SCANNING-TUNNELING-MICROSCOPY, AND ATOMIC-FORCE MICROSCOPY LATTICE STRUCTURES [J].
CHEN, CH ;
KEPLER, KD ;
GEWIRTH, AA ;
OCKO, BM ;
WANG, J .
JOURNAL OF PHYSICAL CHEMISTRY, 1993, 97 (28) :7290-7294
[9]   Electrochemical detection of lead ions via the covalent attachment of human angiotensin I to mercaptopropionic acid and thioctic acid self-assembled monolayers [J].
Chow, E ;
Hibbert, DB ;
Gooding, JJ .
ANALYTICA CHIMICA ACTA, 2005, 543 (1-2) :167-176
[10]   A Single-Use, In Vitro Biosensor for the Detection of T-Tau Protein, A Biomarker of Neuro-Degenerative Disorders, in PBS and Human Serum Using Differential Pulse Voltammetry (DPV) [J].
Dai, Yifan ;
Molazemhosseini, Alireza ;
Liu, Chung Chiun .
BIOSENSORS-BASEL, 2017, 7 (01)