High performance liquid chromatography coupled with atmospheric pressure chemical ionization mass spectrometry for sensitive determination of bioactive amines in donkey milk

被引:34
作者
La Torre, Giovanna Loredana [1 ]
Saitta, Marcello [1 ]
Potorti, Angela Giorgia [1 ]
Di Bella, Giuseppa [1 ]
Dugo, Giacomo [1 ]
机构
[1] Univ Messina, Fac Sci MM FF NN, Dipartimento Sci Alimenti & Ambiente Prof Gugliel, I-98166 Messina, Italy
关键词
Bioactive amines; Dansyl chloride; HPLC-MS; Milk; Donkey; PULSED AMPEROMETRIC DETECTION; BIOGENIC-AMINES; COWS MILK; FLUORESCENCE DETECTION; FLUOROMETRIC DETECTION; DERIVATIZING REAGENT; ALCOHOLIC BEVERAGES; DANSYL DERIVATIVES; INFANT FORMULAS; HUMAN HEALTH;
D O I
10.1016/j.chroma.2010.06.022
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the present study we report on the optimization and validation of a sensitive high performance liquid chromatography atmospheric pressure chemical ionization mass spectrometry (HPLC-APCI-MS) method for the determination of 8 bioactive amines (histamine, tyramine, tryptamine, 2-phenylethylamine, cadaverine, putrescine, spermidine and spermine) in donkey milk samples. The method involves donkey milk pre-treatment to remove proteins and pre-column dansylation of the amines. HPLC in reversed phase mode has been used for bioactive amines separation and the operating condition of the APCI-MS system proved to be powerful and very efficient for peak assignment. The separation was accomplished in a short time with an excellent resolution for all the amine peaks. Quantification was carried out by monitoring the characteristic [M+H](+) ion of each amine derivative. The method sensitivity, linearity and repeatability were assayed with satisfactory results. The detection limits of the analysed amines ranged from 0.5 mu g L-1 to 15 mu g L-1; the highest LOD was for spermine. Also remarkably good recovery values were obtained; at the lowest spiking level (1 mu g L-1) the percent mean recoveries ranged from 77.7 to 109.7. Furthermore, as the investigations relate to a complex matrix as donkey milk, suitable studies on matrix effect were performed. Finally, the developed and validated method was applied to analyse 13 donkey milk samples. Among the identified bioactive amines, putrescine, spermine and spermidine proved to be the main amines in donkey milk. Their concentration levels in the present study were lower than the values determined in mature human, cow and sow milk. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:5215 / 5224
页数:10
相关论文
共 66 条
[1]  
ABE F, 1977, ANAL BIOCHEM, V67, P109
[2]   Determination of biogenic diamines with a vaporisation derivatisation approach using solid-phase microextraction gas chromatography-mass spectrometry [J].
Awan, M. Ali ;
Fleet, I. ;
Thomas, C. L. Paul .
FOOD CHEMISTRY, 2008, 111 (02) :462-468
[4]   POLYAMINES IN FOOD - IMPLICATIONS FOR GROWTH AND HEALTH [J].
BARDOCZ, S ;
GRANT, G ;
BROWN, DS ;
RALPH, A ;
PUSZTAI, A .
JOURNAL OF NUTRITIONAL BIOCHEMISTRY, 1993, 4 (02) :66-71
[5]   High-performance liquid chromatographic determination of polyamines in milk as their 9-fluorenylmethoxycarbonyl derivatives using a column-switching technique [J].
Bellagamba, F ;
Moretti, VM ;
Mentasti, T ;
Albertini, A ;
Luzzana, U ;
Valfrè, F .
JOURNAL OF CHROMATOGRAPHY A, 1997, 791 (1-2) :79-84
[6]   Determination of biogenic amines by RP HPLC of the dabsyl derivates [J].
Bockhardt, A ;
Krause, I ;
Klostermeyer, H .
ZEITSCHRIFT FUR LEBENSMITTEL-UNTERSUCHUNG UND-FORSCHUNG, 1996, 203 (01) :65-70
[7]   GAS CHROMATOGRAPHIC ANALYSIS OF AMINES AND OTHER COMPOUNDS PRODUCED BY SEVERAL SPECIES OF CLOSTRIDIUM [J].
BROOKS, JB ;
MOORE, WEC .
CANADIAN JOURNAL OF MICROBIOLOGY, 1969, 15 (12) :1433-&
[8]   POLYAMINE PROFILES IN HUMAN-MILK, INFANT ARTIFICIAL FORMULAS, AND SEMIELEMENTAL DIETS [J].
BUTS, JP ;
DEKEYSER, N ;
DERAEDEMAEKER, L ;
COLLETTE, E ;
SOKAL, EM .
JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 1995, 21 (01) :44-49
[9]   An interference free amperometric biosensor for the detection of biogenic amines in food products [J].
Carelli, Donatella ;
Centonze, Diego ;
Palermo, Carmen ;
Quinto, Maurizio ;
Rotunno, Taddeo .
BIOSENSORS & BIOELECTRONICS, 2007, 23 (05) :640-647
[10]  
Carroccio A, 2000, CLIN EXP ALLERGY, V30, P1597, DOI 10.1046/j.1365-2222.2000.00925.x