Direct tensile behavior of amorphous metallic fiber-reinforced cementitious composites: Effect of fiber length, fiber volume fraction, and strain rate

被引:17
作者
Kim, Hongseop [1 ]
Kim, Gyuyong [2 ]
Lee, Sangkyu [2 ]
Choe, Gyeongcheol [2 ]
Noguchi, Takafumi [3 ]
Nam, Jeongsoo [2 ]
机构
[1] Korea Inst Civil Engn & Bldg Technol, Dept Living & Built Environm Res, Bldg Safety Res Ctr, 283 Goyang Daero, Goyang Si 10223, Gyeonggi Do, South Korea
[2] Chungnam Natl Univ, Dept Architectural Engn, 99 Daehak Ro, Daejeon 34134, South Korea
[3] Univ Tokyo, Grad Sch Engn, Dept Architecture, Bunkyo Ku, 7-3-1 Hongo, Tokyo 1138656, Japan
基金
新加坡国家研究基金会;
关键词
Amorphous metallic fiber; Direct tensile behavior; Fiber length; Fiber volume fraction; Strain rate; Dynamic increase factor; STEEL FIBER; MECHANICAL-PROPERTIES; PULL-OUT; PERFORMANCE; CONCRETE; RESISTANCE; STRENGTH; IMPACT;
D O I
10.1016/j.compositesb.2019.107430
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this study, the effects of the fiber length, fiber volume fraction, and strain rate on amorphous metallic fiber-reinforced cementitious composites (AFRCCs) were investigated. The experimental results showed that the amorphous metallic fibers with a 30 mm length had excellent bonding performance with the matrix because of the rough fiber surface, large specific surface area, and high aspect ratio under both static and high strain rate conditions. The fibers, however, were not pulled out from the matrix and were subjected to fracture because the thin-plate shape of the fibers was vulnerable to shear force. On the other hand, the amorphous metallic fibers with a 15 mm length exhibited decreased bonding efficiency with the matrix because of the low aspect ratio and the increased number of mixed fibers, and the fibers were pulled out from the matrix. As the fiber length increased, the tensile strength, strain capacity, and tensile toughness increased because the stress dispersion effect increased alongside the increase in the internal binding force and the crosslinking reaction range inside the matrix. As for the dynamic increase factor (DIF), the amorphous metallic fibers with a 30 mm length exhibited fracture without being pulled out from the matrix. The amorphous metallic fibers with a 15 mm length, however, were pulled out from the matrix, thereby increasing the bonding efficiency of the fiber-matrix interface that is affected by the strain rate. Therefore, it was found that AFRCC-L15 had a higher DIF for the tensile strength, strain capacity, and tensile toughness.
引用
收藏
页数:11
相关论文
共 41 条
[11]  
Fujikake K, 2001, J MAT CONCRETE STRUC, V669, P125
[12]   Response of ultra-high performance fiber reinforced concrete (UHPFRC) to impact and static loading [J].
Habel, Katrin ;
Gauvreau, Paul .
CEMENT & CONCRETE COMPOSITES, 2008, 30 (10) :938-946
[13]  
Hameed R, 2010, MAEJO INT J SCI TECH, V4, P169
[14]  
Jeong G.Y., 2018, J KOREA CONCR I, V30, P197, DOI [10.4334/JKCI.2018.30.2.197, DOI 10.4334/JKCI.2018.30.2.197]
[15]   Interface property and apparent strength of high-strength hydrophilic fiber in cement matrix [J].
Kanda, T ;
Li, VC .
JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 1998, 10 (01) :5-13
[16]   Effect of embedment length on pullout behavior of amorphous steel fiber in Portland cement composites [J].
Kim, Baek-Joong ;
Yi, Chongku ;
Ahn, Yu-ri .
CONSTRUCTION AND BUILDING MATERIALS, 2017, 143 :83-91
[17]   Strain rate effects on the compressive and tensile behavior of bundle-type polyamide fiber-reinforced cementitious composites [J].
Kim, Hongseop ;
Kim, Gyuyong ;
Lee, Sangkyu ;
Son, Minjae ;
Choe, Gyeongcheol ;
Nam, Jeongsoo .
COMPOSITES PART B-ENGINEERING, 2019, 160 :50-65
[18]   Static mechanical properties and impact resistance of amorphous metallic fiber-reinforced concrete [J].
Kim, Hongseop ;
Kim, Gyuyong ;
Nam, Jeongsoo ;
Kim, Junghyun ;
Han, Sanghyu ;
Lee, Sanggyu .
COMPOSITE STRUCTURES, 2015, 134 :831-844
[19]   High-rate tensile behavior of steel fiber-reinforced concrete for nuclear power plants [J].
Kim, Jung Jin ;
Park, Gi-Joon ;
Kim, Dong Joo ;
Moon, Jae Heurn ;
Lee, Jang Hwa .
NUCLEAR ENGINEERING AND DESIGN, 2014, 266 :43-54
[20]  
박경우, 2014, [Journal of the Korea Concrete Institute, 콘크리트학회 논문집], V26, P475, DOI 10.4334/JKCI.2014.26.4.475