Heterocyclic aromatic amines in doner kebab: Quantitation using an efficient microextraction technique coupled with reversed-phase high-performance liquid chromatography

被引:7
作者
Mohammadi, Abdorreza [1 ,2 ]
Barzegar, Fatemeh [1 ]
Kamankesh, Marzieh [1 ]
Khaneghah, Amin Mousavi [3 ]
机构
[1] Shahid Beheshti Univ Med Sci, Natl Nutr & Food Technol Res Inst, Fac Nutr Sci Food Sci & Technol, Dept Food Sci & Technol, Tehran, Iran
[2] Shahid Beheshty Univ Med Sci, Food Safety Res Ctr, Tehran, Iran
[3] Univ Estadual Campinas, UNICAMP, Fac Food Engn, Dept Food Sci, Rua Monteiro Lobato,80,Caixa Postal 6121, BR-13083862 Campinas, SP, Brazil
关键词
central composite design; doner kebab; Heterocyclic aromatic amines; instrumental analysis; meat product; microextraction; MICROWAVE-ASSISTED EXTRACTION; MASS-SPECTROMETRY; MEAT; RISK; CANCER; FOOD; QUANTIFICATION; OPTIMIZATION; HYDROCARBONS; ARRAY;
D O I
10.1002/fsn3.1262
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
The safety of doner kebab as a traditional Middle East tasty food can threaten via the formation of dangerous compounds such as heterocyclic aromatic amines during heat process. In this regard, the current investigation was devoted to measuring of 4 HAAs (2-amino-3,4-dimethylimidazo[4,5-f]quinoline (MeIQ), 2-amino-3,8-dimethylimidazo[4,5-f]quinoxaline (MeIQx), 2-amino-1-methyl-6-phenylimidazo[4,5-b]pyridine (PhIP), and 2-amino-3-methylimidazo[4,5-f]quinoline (IQ)) in doner kebab samples with an innovative microextraction technique combined with high-performance liquid chromatography. The limit of detection was in the range of 4.8 and 5.3 ng/g, while relative standard deviations were between 6.5% and 8.3%, and recoveries were calculated in the range of 89%-97%. The most and the least total mean values of HAA levels were 13.30 ng/g for MeIQx and 5.0 ng/g for IQ. The proposed method showed a high capability to extract trace amount of HAAs from a complex matrix such as doner kebab. Also, this technique is easy, high sensitive, selective, accurate and efficient.
引用
收藏
页码:88 / 96
页数:9
相关论文
共 32 条
[1]   Evaluation and application of microwave-assisted extraction and dispersive liquid-liquid microextraction followed by high-performance liquid chromatography for the determination of polar heterocyclic aromatic amines in hamburger patties [J].
Aeenehvand, Saeed ;
Toudehrousta, Zahra ;
Kamankesh, Marzieh ;
Mashayekh, Morteza ;
Tavakoli, Hamid Reza ;
Mohammadi, Abdorreza .
FOOD CHEMISTRY, 2016, 190 :429-435
[2]   Analysis of non-polar heterocyclic aromatic amines in beefburguers by using microwave-assisted extraction and dispersive liquid-ionic liquid microextraction [J].
Agudelo Mesa, Leidy B. ;
Padro, Juan M. ;
Reta, Mario .
FOOD CHEMISTRY, 2013, 141 (03) :1694-1701
[3]   Microwave-assisted extraction of phenolic antioxidant compounds from peanut skins [J].
Ballard, Tameshia S. ;
Mallikarjunan, Parameswarakumar ;
Zhou, Kequan ;
O'Keefe, Sean .
FOOD CHEMISTRY, 2010, 120 (04) :1185-1192
[4]   Comparison of dimethylformamide dialkylacetal derivatization reagents for the analysis of heterocyclic amines in meat extracts by gas chromatography-mass spectrometry [J].
Barceló-Barrachina, E ;
Santos, FJ ;
Puignou, L ;
Galceran, MT .
ANALYTICA CHIMICA ACTA, 2005, 545 (02) :209-217
[5]   Heterocyclic aromatic amines in cooked food: A review on formation, health risk-toxicology and their analytical techniques [J].
Barzegar, Fatemeh ;
Kamankesh, Marzieh ;
Mohammadi, Abdorreza .
FOOD CHEMISTRY, 2019, 280 (240-254) :240-254
[6]   Analysis of heterocyclic aromatic amines in foods by gas chromatography-mass spectrometry as their tert.-butyldimethylsilyl derivatives [J].
Casal, S ;
Mendes, E ;
Fernandes, JO ;
Oliveira, MBPP ;
Ferreira, MA .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1040 (01) :105-114
[7]   Response surface optimization of effects of some processing variables on carcinogenic/mutagenic heterocyclic aromatic amine (HAA) content in cooked patties [J].
Dundar, Adnan ;
Saricoban, Cemalettin ;
Yilmaz, Mustafa Tahsin .
MEAT SCIENCE, 2012, 91 (03) :325-333
[8]   Isolation by solid-phase extraction and liquid chromatographic determination of mutagenic amines in beef extracts [J].
Galceran, MT ;
Pais, P ;
Puignou, L .
JOURNAL OF CHROMATOGRAPHY A, 1996, 719 (01) :203-212
[9]   Microwave-assisted extraction and dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometry for isolation and determination of polycyclic aromatic hydrocarbons in smoked fish [J].
Ghasemzadeh-Mohammadi, Vahid ;
Mohammadi, Abdorreza ;
Hashemi, Maryam ;
Khaksar, Ramin ;
Haratian, Parivash .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1237 :30-36
[10]   Optimization of mead production using Response Surface Methodology [J].
Gomes, Teresa ;
Barradas, Carla ;
Dias, Teresa ;
Verdial, Joao ;
Morais, Jorge Sa ;
Ramalhosa, Elsa ;
Estevinho, Leticia M. .
FOOD AND CHEMICAL TOXICOLOGY, 2013, 59 :680-686