Physiological relevant in vitro evaluation of polymer coats for gastroretentive floating tablets

被引:27
作者
Eisenaecher, Friederike [1 ]
Garbacz, Grzegorz [2 ]
Maeder, Karsten. [1 ]
机构
[1] Univ Halle Wittenberg, Inst Pharm, D-06120 Halle, Saale, Germany
[2] Physiolution GmbH, Greifswald, Germany
关键词
Floating; Bilayer tablets; Gastroretentive drug delivery systems; Stress test; Texture analyser; Metformin-HCl; Eudragit (R) RL 30D; Kollicoat (R) SR 30D; DRUG-DELIVERY SYSTEMS; EXTENDED-RELEASE TABLETS; DOSAGE FORMS; ABSORPTION;
D O I
10.1016/j.ejpb.2014.07.009
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Gastroretentive drug delivery systems are retained in the stomach for a sufficient time interval, releasing the drug in a controlled manner. According to literature, the floating principle is the most frequently used formulation approach for gastric retention. However, many publications lack information of the floating forces, the impact of different pH-values and almost no information exist concerning the resistance of the floating performance against physiological relevant stress. Therefore, we evaluated the performance of CO2-generating floating bilayer (drug and floating layer) tablets with respect to robustness, drug release profile, pH dependence and floating behaviour. Bilayer tablets were coated with a flexible and water permeable, but CO2-retaining polymer film of either polyvinyl acetate or ammonio-methacrylate copolymer type A. Metformin-HCl was used as a relevant model drug due to its dose-dependent and saturable absorption from the proximal part of the small intestine. To mimic physiological relevant mechanical stress conditions, recently developed dissolution stress tests with pulsed pressures were applied in addition to release studies according to the pharmacopeia. Bilayer tablets coated with polyvinyl acetate showed short floating lag times, reasonable floating strength values, floating durations of more than 24 h in simulated gastric fluid and a robust and pH independent release of Metformin-HCl. Tablets coated with ammonio-methacrylate copolymer type A showed a higher permeability for the active ingredient combined with a decreased robustness of the inflated tablets. Both polymers can be used for balloon-like floating devices. The appropriate polymer has to be chosen dependent from the properties of the active ingredient and requested application of the delivery device. Furthermore, the dissolution stress test analysis is able to indicate possible safety issues of gastroretentive formulations as well as to characterise the robustness of formulation principles towards mechanical stresses of bio-relevant intensity. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:778 / 786
页数:9
相关论文
共 36 条
[1]   A novel in vitro and numerical analysis of shear-induced drug release from extended-release tablets in the fed stomach [J].
Abrahamsson, B ;
Pal, A ;
Sjöberg, M ;
Carlsson, M ;
Laurell, E ;
Brasseur, JG .
PHARMACEUTICAL RESEARCH, 2005, 22 (08) :1215-1226
[2]   Floating drug delivery systems: A review [J].
Arora, S ;
Ali, J ;
Ahuja, A ;
Khar, RK ;
Baboota, S .
AAPS PHARMSCITECH, 2005, 6 (03) :E372-E390
[3]   Gastroretentive dosage forms:: Overview and special case of Helicobacter pylori [J].
Bardonnet, PL ;
Faivre, V ;
Pugh, WJ ;
Piffaretti, JC ;
Falson, F .
JOURNAL OF CONTROLLED RELEASE, 2006, 111 (1-2) :1-18
[4]  
BASF AG, TECHN INF KOLL SR KO
[5]   The influence of buffer species and strength on diltiazem HCl release from beads coated with the aqueous cationic polymer dispersions, eudragit RS, RL 30D [J].
Bodmeier, R ;
Guo, XD ;
Sarabia, RE ;
Skultety, PF .
PHARMACEUTICAL RESEARCH, 1996, 13 (01) :52-56
[6]   Advantage of expressing the variations in some digestive parameters as a function of gastric emptying instead of time [J].
Carrière, F ;
Renou, C ;
Ville, E ;
Grandval, P ;
Laugier, R .
DIGESTION, 2001, 64 (01) :46-53
[7]  
El S. Samaligy, 2010, THESIS FREIE U BERLI
[8]   Safety and Robustness of Coated Pellets: Self-Healing Film Properties and Storage Stability [J].
Ensslin, Simon ;
Moll, Klaus Peter ;
Haefele-Racin, Thomas ;
Maeder, Karsten .
PHARMACEUTICAL RESEARCH, 2009, 26 (06) :1534-1543
[9]  
Evonik Industries AG, 2012, EUDR PROD BROCH ACR
[10]   Irregular absorption profiles observed from diclofenac extended release tablets can be predicted using a dissolution test apparatus that mimics in vivo physical stresses [J].
Garbacz, Grzegorz ;
Wedemeyer, Ralph-Steven ;
Nagel, Stefan ;
Giessmann, Thomas ;
Moennikes, Hubert ;
Wilson, Clive G. ;
Siegmund, Werner ;
Weitschies, Werner .
EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2008, 70 (02) :421-428