Using the iterative kV CBCT reconstruction on the Varian Halcyon linear accelerator for radiation therapy planning for pelvis patients

被引:48
作者
Jarema, Talia [1 ]
Aland, Trent [1 ]
机构
[1] Icon Canc Ctr, Brisbane, Qld, Australia
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2019年 / 68卷
关键词
Halcyon; CBCT; Radiation therapy planning; CT;
D O I
10.1016/j.ejmp.2019.11.015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The ability to utilise a linear accelerators kV cone beam CT, for treatment planning and dosimetry calculation, has a number of potential uses including adaptive planning and daily dose analysis. This work validates the use of the iterative reconstruction of the Varian Halcyon cone beam CT (iCBCT) as datasets for radiation therapy planning of pelvis patients. Methods: A CT to electron density (ED) curve was created in the Varian Eclipse treatment planning system (TPS) using scans of a CIRS ED phantom under a variety of scattering conditions. A pelvis phantom was imaged using a diagnostic CT scanner and Halcyon iCBCT. Ten pelvis patient plans were copied onto each dataset and compared using a global 3D gamma analysis. Each patient being treated on Halcyon has a daily iCBCT, and each plan was also recalculated on their respective day 1 iCBCT dataset. Results: 3D Gamma analysis results for the patients planned on the pelvis phantom were analysed using a 1%/1 mm and 2%/2 mm, 10% low dose threshold criteria. The average pass rate was 99.4% +/- 0.2%. The same metrics were used to analyse the patient plans recalculated on day 1 iCBCTs. The average result for the 1%/1 mm gamma analysis was 94.4% +/- 6.1%, and 98.6% +/- 2.0% for 2%/2 mm. A comparison of typical patient volumes showed average mean dose volume differences of 0.0% +/- 1.4%, 0.0% +/- 0.9% and 1.0% +/- 4.0% for the PTV, Bladder and Rectum volumes respectively. Conclusions: Halcyon iCBCT datasets can be used for dose calculation in radiation therapy treatment planning for pelvis patients.
引用
收藏
页码:112 / 116
页数:5
相关论文
共 11 条
[1]   Characterization of a prototype rapid kilovoltage x-ray image guidance system designed for a ring shape radiation therapy unit [J].
Cai, Bin ;
Laugeman, Eric ;
Mazur, Thomas R. ;
Park, Justin C. ;
Henke, Lauren E. ;
Kim, Hyun ;
Hugo, Geoffrey D. ;
Mutic, Sasa ;
Li, Hua .
MEDICAL PHYSICS, 2019, 46 (03) :1355-1370
[2]   Target position variability throughout prostate radiotherapy [J].
Dawson, LA ;
Mah, K ;
Franssen, E ;
Morton, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (05) :1155-1161
[3]   Variability of bladder filling in patients receiving radical radiotherapy to the prostate [J].
Doherty, Una M. ;
McNair, Helen A. ;
Norman, Andrew R. ;
Miles, Elizabeth ;
Hooper, Simon ;
Davies, Mark ;
Lincoln, Naomi ;
Balyckyi, Jan ;
Childs, Peter ;
Dearnaley, David P. ;
Huddart, Robert A. .
RADIOTHERAPY AND ONCOLOGY, 2006, 79 (03) :335-340
[4]   Dose calculation accuracy using cone-beam CT (CBCT) for pelvic adaptive radiotherapy [J].
Guan, Huaiqun ;
Dong, Hang .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (20) :6239-6250
[5]   The dosimetric consequences of anatomic changes in head and neck radiotherapy patients [J].
Height, Rebecca ;
Khoo, Vincent ;
Lawford, Catherine ;
Cox, Jennifer ;
Joon, Daryl Lim ;
Rolfo, Aldo ;
Wada, Morikatsu .
JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2010, 54 (05) :497-504
[6]   Multi-slice helical CT: Scan and reconstruction [J].
Hu, H .
MEDICAL PHYSICS, 1999, 26 (01) :5-18
[7]  
Jin J, 2001, MED PHYS, V37, P5634
[8]   Interfractional variations in patient setup and anatomic change assessed by daily computed tomography [J].
Li, X. Allen ;
Qi, X. Sharon ;
Pitterle, Marissa ;
Kalakota, Kapila ;
Mueller, Kevin ;
Erickson, Beth A. ;
Wang, Dian ;
Schultz, Christopher J. ;
Firat, Selim Y. ;
Wilson, J. Frank .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (02) :581-591
[9]   Investigation of the usability of conebeam CT data sets for dose calculation [J].
Richter, Anne ;
Hu, Qiaoqiao ;
Steglich, Doreen ;
Baier, Kurt ;
Wilbert, Juergen ;
Guckenberger, Matthias ;
Flentje, Michael .
RADIATION ONCOLOGY, 2008, 3 (1)
[10]   Cone-beam computed tomography with a flat-panel imager: Magnitude and effects of x-ray scatter [J].
Siewerdsen, JH ;
Jaffray, DA .
MEDICAL PHYSICS, 2001, 28 (02) :220-231