Effectiveness of ProTaper Universal retreatment instruments used with rotary or reciprocating adaptive motion in the removal of root canal filling material

被引:22
作者
Capar, I. D. [1 ]
Arslan, H. [2 ]
Ertas, H. [1 ]
Gok, T. [1 ]
Saygili, G. [1 ]
机构
[1] Izmir Katip Celebi Univ, Fac Dent, Dept Endodont, TR-35620 Izmir, Turkey
[2] Ataturk Univ, Fac Dent, Dept Endodont, Erzurum, Turkey
关键词
adaptive; endodontics; ProTaper Universal retreatment files; reciprocal; retreatment; root canal filling; GUTTA-PERCHA; NITI INSTRUMENTS; CYCLIC FATIGUE; EFFICACY; HAND; FILES;
D O I
10.1111/iej.12279
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To compare the effectiveness of ProTaper Universal retreatment instruments with continuous rotation and adaptive motion (AM; a modified reciprocating motion that combines rotational and reciprocating motion) in the removal of filling material. Methodology Mesiobuccal root canals in 36 mandibular first molars were instrumented up to size F2 with the ProTaper Universal instrument (Dentsply Maillefer, Ballaigues, Switzerland) and filled using sealer and ProTaper Universal F2 gutta-percha cones. Gutta-percha was then down-packed and the root canal backfilled using the extruder hand-piece of the Elements Obturation System (SybronEndo, Orange, CA, USA). The teeth were assigned to two groups (n = 18), and removal of the root fillings was performed using one of the following techniques: group 1) ProTaper Universal retreatment files used with rotational motion (RM) and group 2) ProTaper Universal retreatment files used with adaptive motion (AM) (600 degrees clockwise/0 degrees counter-clockwise to 370 degrees clockwise/50 degrees counter-clockwise). The teeth were sectioned, and both halves were analysed at 8 9 magnification. The percentage of remaining filling material was recorded. The data were analysed statistically using the Student's t-test at a 95% confidence level (P < 0.05). Results There was no significant difference between the groups with respect to the total time required for retreatment (P = 0.481). The AM technique left significantly less filling material than the RM method (P = 0.013). Conclusion The use of ProTaper Universal retreatment files with adaptive motion removed more filling materials from root canals than the rotational movement.
引用
收藏
页码:79 / 83
页数:5
相关论文
共 26 条
[1]   Effectiveness of HERO 642 versus Hedstrom files for removing gutta-percha fillings in curved root canals: an ex vivo study [J].
Aydin, B. ;
Kose, T. ;
Caliskan, M. K. .
INTERNATIONAL ENDODONTIC JOURNAL, 2009, 42 (11) :1050-1056
[2]   Computed tomography assessment of three techniques for removal of filling material [J].
Barletta, Fernando Branco ;
Reis, Magda de Sousa ;
Wagner, Marcia ;
Borges, Janusa Casali ;
Dall'Agnol, Cristina .
AUSTRALIAN ENDODONTIC JOURNAL, 2008, 34 (03) :101-105
[3]   Comparative Study of Different Novel Nickel-Titanium Rotary Systems for Root Canal Preparation in Severely Curved Root Canals [J].
Capar, Ismail Davut ;
Ertas, Huseyin ;
Ok, Evren ;
Arslan, Hakan ;
Ertas, Elif Tarim .
JOURNAL OF ENDODONTICS, 2014, 40 (06) :852-856
[4]   Efficacy of automated versus hand instrumentation during root canal retreatment:: an ex vivo study [J].
de Carvalho Maciel, A. C. ;
Zaccaro Scelza, M. F. .
INTERNATIONAL ENDODONTIC JOURNAL, 2006, 39 (10) :779-784
[5]   The efficacy of ProTaper Universal rotary retreatment instrumentation to remove single gutta-percha cones cemented with several endodontic sealers [J].
Ersev, H. ;
Yilmaz, B. ;
Dincol, M. E. ;
Daglaroglu, R. .
INTERNATIONAL ENDODONTIC JOURNAL, 2012, 45 (08) :756-762
[6]   The efficacy of gutta-percha removal using ProFiles [J].
Ferreira, JJ ;
Rhodes, JS ;
Ford, TRP .
INTERNATIONAL ENDODONTIC JOURNAL, 2001, 34 (04) :267-274
[7]  
FRIEDMAN S, 1993, INT ENDOD J, V26, P169
[8]   Cyclic fatigue analysis of twisted file rotary NiTi instruments used in reciprocating motion [J].
Gambarini, G. ;
Gergi, R. ;
Naaman, A. ;
Osta, N. ;
Al Sudani, D. .
INTERNATIONAL ENDODONTIC JOURNAL, 2012, 45 (09) :802-806
[9]  
Gambarini Gianluca, 2013, Ann Stomatol (Roma), V4, P152, DOI 10.11138/ads.0152
[10]   Influence of Different Angles of Reciprocation on the Cyclic Fatigue of Nickel-Titanium Endodontic Instruments [J].
Gambarini, Gianluca ;
Rubini, Alessio Giansiracusa ;
Al Sudani, Dina ;
Gergi, Richard ;
Culla, Antonio ;
De Angelis, Francesca ;
Di Carlo, Stefano ;
Pompa, Giorgio ;
Osta, Nada ;
Testarelli, Luca .
JOURNAL OF ENDODONTICS, 2012, 38 (10) :1408-1411